狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            上海湘杰儀器儀表科技有限公司

            當前位置:首頁   >>   資料下載   >>   雙向拉伸聚丙烯珠光薄膜

            雙向拉伸聚丙烯珠光薄膜

            時間:2009/7/30閱讀:2463
            • 提供商

              上海湘杰儀器儀表科技有限公司
            • 資料大小

              0K
            • 資料圖片

              查看
            • 下載次數(shù)

              283次
            • 資料類型

              未傳
            • 瀏覽次數(shù)

              2463次

             

            12.1.7 Crosshead speed (rate of grip separation),
            12.1.8 Gage length (if different from grip separation),
            12.1.9 Type of grips used, including facing (if any),
            12.1.10 Conditioning procedure (test conditions, temperature,
            and relative humidity if nonstandard),
            12.1.11 Anomalous behavior such as tear failure and failure
            at a grip,
            12.1.12 Average breaking factor and standard deviation,
            12.1.13 Average tensile strength (nominal) and standard
            deviation,
            12.1.14 Average tensile strength at break (nominal) and
            standard deviation,
            12.1.15 Average percent elongation at break and standard
            deviation,
            12.1.16 Where applicable, average tensile energy to break
            and standard deviation,
            12.1.17 In the case of materials exhibiting “yield” phenomenon:
            average yield strength and standard deviation; and
            average percent elongation at yield and standard deviation,
            12.1.18 For materials which do not exhibit a yield point:
            average —% offset yield strength and standard deviation; and
            average percent elongation at —% offset yield strength and
            standard deviation,
            12.1.19 Average modulus of elasticity and standard deviation
            (if secant modulus is used, so indicate and report strain at
            which calculated), and
            12.1.20 When an extensometer is employed, so indicate.
            13. Precision and Bias
            13.1 Two interlaboratory tests have been run for these
            tensile properties. The first was run for modulus only, in 1977,
            in which randomly drawn samples of four thin (; 0.025 mm
            (0.001-in.)) materials were tested with five specimens in each
            laboratory. Elastic (tangent) modulus measurements were
            made by six laboratories, and secant (1 %) modulus measurements
            were taken by five laboratories. The relative precision
            obtained in this interlaboratory study is in Table 2.
            13.1.1 In deriving the estimates in Table 2, statistical
            outliers were not removed, in keeping with Practice E 691.9
            13.1.2 The within-lab standard deviation of a mean value, S
            x? , in each case was determined from the standard deviation, S
            x? , of the five individual specimens as follows: S x? = Sx /(5)1?2.
            The S x? values were pooled among laboratories for a given
            material to obtain the within-lab standard deviation, Sr , of a
            test result (mean of five specimens). See 13.3-13.3.2 for
            definitions of terms in the tables.
            13.2 An interlaboratory test was run for all the other tensile
            properties except modulus in 1981, in which randomly drawn
            samples of six materials (one of these in three thicknesses)
            ranging in thickness from 0.019 to 0.178 mm (0.00075 to 0.007
            in.) were tested in seven laboratories. A test result was defined
            as the mean of five specimen determinations. However, each
            laboratory tested eight specimens, and the S x? was determined
            from S x? = Sx /(5)1?2 as above. This was done to improve the
            quality of the statistics while maintaining their applicability to
            a five-specimen test result. The materials and their thicknesses
            are identified in Tables 3-7, each of which contain data for one
            of the following properties: tensile yield stress, yield elongation,
            tensile strength, tensile elongation at break, and tensile
            9 Supporting data are available from ASTM Headquarters. Request RR: D20-
            1084.
            TABLE 3 Precision Data for Yield Stress
            Material Thickness, mils Average, 103 psi (Sr)A 103 psi (SR)B 103 psi I(r)C 103 psi I(R)D 103 psi
            LDPE 1.0 1.49 0.051 0.13 0.14 0.37
            HDPE 1.0 4.33 0.084 0.16 0.24 0.44
            PP 0.75 6.40 0.13 0.52 0.37 1.46
            PC 4.0 8.59 0.072 0.29 0.20 0.82
            CTA 5.3 11.4 0.12 0.50 0.34 1.43
            PET 4.0 14.3 0.12 0.23 0.34 0.66
            PET 2.5 14.4 0.14 0.54 0.40 1.52
            PET 7.0 14.4 0.13 0.36 0.37 1.03
            A S r is the within-laboratory standard deviation of the average.
            B SR is the between-laboratories standard deviation of the average.
            C Ir = 2.83 Sr.
            D I R = 2.83 SR.

            塑料薄板拉力機;塑料薄板拉力機維修;塑料薄板拉力機報價

            會員登錄

            X

            請輸入賬號

            請輸入密碼

            =

            請輸驗證碼

            收藏該商鋪

            X
            該信息已收藏!
            標簽:
            保存成功

            (空格分隔,最多3個,單個標簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復您~

            以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責,化工儀器網(wǎng)對此不承擔任何保證責任。

            溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務必確認供應商資質(zhì)及產(chǎn)品質(zhì)量。

            撥打電話
            在線留言