            人嗜環(huán)蛋白親環(huán)素B(CyPB)ELISA Kit

            時(shí)間:2012/8/6閱讀:547
            分享:

            人嗜環(huán)蛋白親環(huán)素B(CyPB)ELISA Kit Human cyclophilin B (CyPB)
            ELISA Kit
            (96 T)
            ? This immunoassay kit allows for the in vitro quantitative determination of human
            CyPB concentrations in serum, plasma, cell culture supernates, tissue
            homogenates.
            ? Expiration date six months from the date of manufacture
            ? FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
            2
            PRINCIPLE OF THE ASSAY
            The microtiter plate provided in this kit has been pre-coated with an
            antibody specific to CyPB. Standards or samples are then added to
            the appropriate microtiter plate wells with a biotin-conjugated
            antibody preparation specific for CyPB and Avidin conjugated to
            Horseradish Peroxidase (HRP) is added to each microplate well
            and incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine)
            substrate solution is added to each well. Only those wells that
            contain CyPB, biotin-conjugated antibody and enzyme-conjugated
            Avidin will exhibit a change in color. The enzyme-substrate reaction
            is terminated by the addition of a sulphuric acid solution and the
            color change is measured spectrophotometrically at a wavelength
            of 450 nm ± 2 nm. The concentration of CyPB in the samples is
            then determined by comparing the O.D. of the samples to the
            standard curve.
            DETECTION RANGE
            The standard curve concentrations used for the ELISA’s are
            ranging from 1.25 ng/ml -80 ng/ml.
            SPECIFICITY
            This assay recognizes human CyPB. No significant cross-reactivity
            or interference was observed.
            3
            SENSITIVITY
            The minimum detectable dose of human CyPB is typically less than
            0.312 ng/ml.
            The sensitivity of this assay, or Lower Limit of Detection (LLD) was
            defined as the lowest protein concentration that could be
            differentiated from zero.
            MATERIALS PROVIDED AND STORAGE
            Reagent Quantity Storage
            Unopened kit Store at 2 - 8° C. Do not use beyond kit expiration date.
            Opened kit
            Coated plate 1
            May be stored for up to 1
            month at 2 - 8° C. Try to
            keep it in a sealed
            aluminum foil bag,and
            avoid the damp
            Standard 2 May be stored for up to 1
            month at 2 - 8° C. If don’t
            make recent use, better
            keep it store at -20℃.
            Biotin-antibody 1 x120ul
            HRP-avidin 1 x120ul
            Sample Diluent 1 x 20 ml
            May be stored for up to 1
            month at 2 - 8° C.
            Biotin-antibody
            Diluent
            1 x 10 ml
            HRP-avidin
            Diluent
            1 x 10 ml
            Wash Buffer
            1 x 20 ml
            (25×concentrate)
            TMB Substrate 1 x 10 ml
            Stop Solution 1 x 10 ml
            4
            REAGENT PREPARATION
            Bring all reagents to room temperature before use for 30min..
            1. Wash Buffer If crystals have formed in the concentrate, warm
            up to room temperature and mix gently until the crystals have
            compley dissolved. Dilute 20 ml of Wash Buffer Concentrate
            into deionized or distilled water to prepare 500 ml of Wash
            Buffer.
            2. Biotin-antibody Centrifuge the vial before opening. Dilute to
            the working concentration using Biotin-antibody
            Diluent(1:100), respectively. The suggested 100-fold dilution
            can be achieved by adding 10 uL Biotin-antibody to 990uL of
            Biotin-antibody Diluent for 1ml working solution.
            3. HRP-avidin Centrifuge the vial before opening. Dilute to the
            working concentration using HRP-avidin Diluent(1:100),
            respectively. The suggested 100-fold dilution can be achieved
            by adding 10 uL HRP-avidin to 990uL of HRP-avidin Diluent
            for 1ml working solution.
            5
            4. Standard Centrifuge the standard vial at 6000-10000rpm for
            30s. Reconstitute the Standard with 1.0 ml of Sample Diluent.
            This reconstitution produces a stock solution of 80 ng/ml. Allow
            the standard to sit for a minimum of 15 minutes with gentle and
            uniform agitation by pipette with 1ml measuring range prior to
            making serial dilutions. The undiluted standard serves as the
            high standard (80 ng/ml). The Sample Diluent serves as the
            zero standard (0 ng/ml). Prepare fresh for each assay. Use
            within 4 hours and discard after use.
            Standard S7 S6 S5 S4 S3 S2 S1
            Concentration
            (ng/ml)
            80 40 20 10 5 2.5 1.25
            Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye,
            hand, face, and clothing protection when using this material.
            6
            OTHER SUPPLIES REQUIRED
            ? Microplate reader capable of measuring absorbance at 450 nm,
            with the correction wavelength set at 540 nm or 570 nm.
            ? Pipettes and pipette tips.
            ? Deionized or distilled water.
            ? Squirt bottle, manifold dispenser, or automated microplate
            washer.
            ? An incubator which can provide stable incubation conditions up
            to 37°C±0.5°C.
            SAMPLE COLLECTION AND STORAGE
            ? Serum Use a serum separator tube (SST) and allow samples
            to clot for 30 minutes before centrifugation for 15 minutes at
            1000 g. Remove serum and assay immediay or aliquot and
            store samples at -20°C. Centrifuge the sample again after
            thawing before the assay. Avoid repeated freeze-thaw cycles.
            ? Plasma Collect plasma using citrate, EDTA, or heparin as an
            anticoagulant. Centrifuge for 15 minutes at 1000 g within 30
            minutes of collection. Assay immediay or aliquot and store
            samples at -20°C. Centrifuge the sample again after thawing
            before the assay. Avoid repeated freeze-thaw cycles.
            ? Tissue Homogenates 100mg tissue was rinsed with 1X
            7
            PBS, homogenized in 1 mL of 1X PBS and stored overnight at
            -20°C. After two freeze-thaw cycles were performed to break
            the cell membranes, the homogenates were centrifuged for 5
            minutes at 5000xg, 2 - 8°C. The supernate was assayed and
            removed immediay. Alternatively, aliquot and store samples
            at -20°C or -80°C. Centrifuge the sample again after thawing
            before the assay. Avoid repeated freeze-thaw cycles.
            ? Cell Culture Supernates Remove particulates by
            centrifugation for 15 minutes at 1000 x g, 2 - 8°C and assay
            immediay or aliquot and store samples at -20° C or -80°C.
            Avoid repeated freeze-thaw cycles.
            Note: Grossly hemolyzed samples are not suitable for use in this assay.
            ASSAY PROCEDURE
            Bring all reagents and samples to room temperature before use. It is recommended
            that all samples, standards, and controls be assayed in duplicate. All the reagents
            should be added directly to the liquid level in the well. The pipette should avoid
            contacting the inner wall of the well.
            1. Add 100μl of Standard, Blank, or Sample per well. Cover with
            the adhesive strip. Incubate for 2 hours at 37°C.
            2. Remove the liquid of each well, don’t wash.
            8
            3. Add 100μl of Biotin-antibody working solution to each well.
            Incubate for 1 hour at 37°C. Biotin-antibody working solution
            may appear cloudy. Warm up to room temperature and mix
            gently until solution appears uniform.
            4. Aspirate each well and wash, repeating the process three times
            for a total of three washes. Wash: Fill each well with Wash
            Buffer (200μl) and let it stand for 2 minutes, then remove the
            liquid by flicking the plate over a sink. The remaining drops are
            removed by patting the plate on a paper towel. Complete
            removal of liquid at each step is essential to good performance.
            5. Add 100μl of HRP-avidin working solution to each well. Cover
            the microtiter plate with a new adhesive strip. Incubate for 1
            hour at 37°C.
            6. Repeat the aspiration and wash five times as step 4.
            7. Add 90μl of TMB Substrate to each well. Incubate for 15-30
            minutes at 37°C. Keeping the plate away from drafts and other
            temperature fluctuations in the dark.
            8. Add 50μl of Stop Solution to each well when the first four wells
            containing the highest concentration of standards develop
            obvious blue color. If color change does not appear uniform,
            gently tap the plate to ensure thorough mixing.
            9. Determine the optical density of each well within 30 minutes,
            9
            using a microplate reader set to 450 nm.
            CALCULATION OF RESULTS
            Using the professional soft "Curve Exert 1.3" to make a standard curve is
            recommended, which can be downloaded from our web.
            Average the duplicate readings for each standard, control, and
            sample and subtract the average zero standard optical density.
            Create a standard curve by reducing the data using computer
            software capable of generating a four parameter logistic (4-PL)
            curve-fit. As an alternative, construct a standard curve by plotting
            the mean absorbance for each standard on the x-axis against the
            concentration on the y-axis and draw a best fit curve through the
            points on the graph. The data may be linearized by plotting the log
            of the CyPB concentrations versus the log of the O.D. and the best
            fit line can be determined by regression analysis. This procedure
            will produce an adequate but less precise fit of the data. If samples
            have been diluted, the concentration read from the standard curve
            must be multiplied by the dilution factor.
            LIMITATIONS OF THE PROCEDURE
            ? The kit should not be used beyond the expiration date on the kit
            label.
            1 0
            ? Do not mix or substitute reagents with those from other lots or
            sources.
            ? It is important that the Standard Diluent selected for the
            standard curve be consistent with the samples being assayed.
            ? If samples generate values higher than the highest standard,
            dilute the samples with the appropriate Standard Diluent and
            repeat the assay.
            ? Any variation in Standard Diluent, operator, pipetting technique,
            washing technique, incubation time or temperature, and kit age
            can cause variation in binding.
            ? This assay is designed to eliminate interference by soluble
            receptors, binding proteins, and other factors present in
            biological samples. Until all factors have been tested in the
            Immunoassay, the possibility of interference cannot be
            excluded.
            TECHNICAL HINTS
            ? Centrifuge vials before opening to collect contents.
            ? When mixing or reconstituting protein solutions, always avoid
            foaming.
            ? To avoid cross-contamination, change pipette tips between
            additions of each standard level, between sample additions,
            and between reagent additions. Also, use separate reservoirs
            1 1
            for each reagent.
            ? When using an automated plate washer, adding a 30 second
            soak period following the addition of wash buffer, and/or
            rotating the plate 180 degrees between wash steps may
            improve assay precision.
            ? To ensure accurate results, proper adhesion of plate sealers
            during incubation steps is necessary.
            ? Substrate Solution should remain colorless or light blue until
            added to the plate. Keep Substrate Solution protected from light.
            Substrate Solution should change from colorless or light blue to
            gradations of blue.
            ? Stop Solution should be added to the plate in the same order as
            the Substrate Solution. The color developed in the wells will
            turn from blue to yellow upon addition of the Stop Solution.
            Wells that are green in color indicate that the Stop Solution has
            not mixed thoroughly with the Substrate Solution.
            PRECISION
            Intra-assay Precision (Precision within an assay)
            One sample whose concentration between the highest and the
            second standard were tested twenty times on one plate to assess.
            CV%<8%
            Inter-assay Precision (Precision between assays)
            1 2
            One sample whose concentration between the highest and the
            second standard were tested in thirty-five separate assays to
            assess
            CV%<10%
            1 3
            PLATE LAYOUT
            Use this plate layout as a record of standards and samples
            assayed.

            廈門慧嘉生物長(zhǎng)期專業(yè)銷售ELISA試劑盒 ASSAY\ Immunoway\ Santa \ Abcam \ Cst \ jackson \ Pierce \ Sigma \ Amresco \Qiagen \ Cayman \ abnova \ millipore \ invitrogen \ merk \ ebioscience \prospec \ peprotech細(xì)胞因子*。等生物試劑產(chǎn)品。實(shí)驗(yàn)為大,誠(chéng)信經(jīng)營(yíng),為客戶提供“zui高質(zhì)量的產(chǎn)品”和“zui的服務(wù):  : 或登陸http://www.biohj.com(向客服人員索取原版說(shuō)明書)。歡迎廣大老師來(lái)詢!

            會(huì)員登錄

            ×

            請(qǐng)輸入賬號(hào)

            請(qǐng)輸入密碼

            =

            請(qǐng)輸驗(yàn)證碼

            收藏該商鋪

            X
            該信息已收藏!
            標(biāo)簽:
            保存成功

            (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
            撥打電話