            Human Corticotropin Releasing
            Hormone (CRH)
            ELISA Kit
             
             
             
            Catalog No. CSB-E06872h
            (96T)
             
             
             
             
             
             
              This immunoassay kit allows for the in vitro quantitative determination of human
            CRH concentrations in serum and other biological fluids.
              Expiration date      six months from the date of manufacture
              FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
             
             
              2
            INTRODUCTION
            Corticotropin-releasing  hormone  (CRH)  is  a  41-amino  acid
            peptide derived  from a 191-amino acid preprohormone. CRH  is
            secreted  by  the  paraventricular  nucleus  (PVN)  of  the
            hypothalamus  in  response  to stress. Marked  reduction  in CRH
            has been observed in association with Alzheimer's disease, and
            autosomal  recessive  hypothalamic  corticotropin  deficiency  has
            multiple and potentially-fatal metabolic  consequences  including
            hypoglycemia and hepatitis. In addition to being produced in the
            hypothalamus,  CRH  is  also  synthesized  in  peripheral  tissues,
            such as T lymphocytes, and is highly expressed in the placenta.
            In  the placenta, CRH  is a marker  that determines  the  length of
            gestation  and  the  timing  of  parturition  and  delivery.  A  rapid
            increase  in  circulating  levels  of  CRH  occurs  at  the  onset  of
            parturition, suggesting that, in addition to its metabolic functions,
            CRH may act as a trigger for parturition.
            PRINCIPLE OF THE ASSAY
            The microtiter plate provided in this kit has been pre-coated with 
              3
            goat-anti-rabbit antibody. Standards or samples are  then added
            to  the  appropriate  microtiter  plate  wells  with  a  Horseradish
            Peroxidase  (HRP)-conjugated  CRH  and  antibody  preparation
            specific  for CRH,  and  incubated.  Then  substrate  solutions  are
            added to each well. The enzyme-substrate reaction is terminated
            by the addition of a sulphuric acid solution and the color change
            is measured spectrophotometrically at a wavelength of 450 nm ±
            2  nm.  The  concentration  of  CRH  in  the  samples  is  then
            determined  by  comparing  the  O.D.  of  the  samples  to  the
            standard curve.
            DETECTION RANGE
            0.8 ng/ml-40 ng/ml. The standard curve concentrations used for
            the  ELISA’s  were  40  ng/ml,  20  ng/ml,  8  ng/ml,  2.4  ng/ml,  0.8
            ng/ml.
            SPECIFICITY
            This  assay  recognizes  human  CRH.  No  significant
            cross-reactivity or interference was observed. 
              4
            SENSITIVITY
            The minimum  detectable  dose  of  human CRH  is  typically  less
            than 1 ng/ml.
            The sensitivity of  this assay, or Lower Limit of Detection  (LLD)
            was  defined  as  the  lowest  protein  concentration  that  could  be
            differentiated from zero.
            MATERIALS PROVIDED
            Reagent      Quantity
            Assay plate  1
            Standard  5 x 0.5 ml
            HRP-Conjugate  1 x 6ml
            Antibody  1 x 6 ml
            Wash Buffer      
            1 x 15 ml
              (20×concentrate)
            Substrate A    1 x 7 ml
            Substrate B    1 x 7 ml
            Stop Solution      1 x 7 ml
             
            Standard  S1  S2  S3  S4  S5
            Concentration
            (ng/ml)
            0.8    2.4    8    20    40   
              5
            STORAGE
            1. Unopened  test  kits  should  be  stored  at  2-8°C  upon  receipt
            and  the microtiter plate should be kept  in a sealed bag. The
            test kit may be used throughout the expiration date of the kit,
            provided  it  is  stored  as  prescribed  above.  Refer  to  the
            package label for the expiration date.
            2. Opened test plate should be stored at 2-8°C in the aluminum
            foil bag with desiccants to minimize exposure to damp air. The
            kits will remain stable until the expiring date shown, provided it
            is stored as prescribed above.    
            3.  A microtiter  plate  reader with  a  bandwidth  of  10  nm  or  less
            and an optical density  range of 0-3 OD or greater at 450nm
            wavelength  is  acceptable  for  use  in  absorbance
            measurement.
            REAGENT PREPARATION
            1.  Bring all reagents to room temperature before use.  
            2.  Wash  Buffer    If  crystals  have  formed  in  the  concentrate,
            warm  up  to  room  temperature  and  mix  gently  until  the 
              6
            crystals  have  compley  dissolved.  Dilute  15  ml  of Wash
            Buffer Concentrate into deionized or distilled water to prepare
            300 ml of Wash Buffer.
            Precaution: The Stop Solution provided with  this kit  is an acid solution. Wear
            eye, hand, face, and clothing protection when using this material.
            OTHER SUPPLIES REQUIRED
              Microplate  reader capable of measuring absorbance at 450
            nm, with the correction wavelength set at 540 nm or 570 nm.
              Pipettes and pipette tips.
              Deionized or distilled water.
              Squirt bottle, manifold dispenser, or automated microplate
            washer.
              An incubator which can provide stable incubation conditions
            up to 37°C±0.5°C.
            SAMPLE COLLECTION AND STORAGE
              Serum    Use  a  serum  separator  tube  (SST)  and  allow
            samples  to  clot  for  30 minutes  before  centrifugation  for  15
            minutes at 1000 g. Remove serum and assay immediay or 
              7
            aliquot  and  store  samples  at  -20°C. Centrifuge  the  sample
            again  after  thawing  before  the  assay.  Avoid  repeated
            freeze-thaw cycles.
            Note: Grossly hemolyzed samples are not suitable for use in this assay.
            ASSAY PROCEDURE
            Bring  all  reagents  and  samples  to  room  temperature  before  use.  It  is
            recommended that all samples, standards, and controls be assayed in duplicate.
            All  the  reagents  should  be  added  directly  to  the  liquid  level  in  the well.  The
            pipette should avoid contacting the inner wall of the well.
            1.  Set  a  Blank without  any  solution.  Add  50µl  of  Standard  or
            Sample per well.  
            2.  Add 50µl of HRP-Conjugate and 50µl of Antibody  to each
            well. Not to Blank well!
            3.  Cover with the adhesive strip. Incubate for 2 hours at 37° C.  
            4.  Aspirate  each  well  and  wash,  repeating  the  process  three
            times  for a  total of  three washes. Wash: Fill each well with
            Wash  Buffer  (200µl)  and  let  it  stand  for  2  minutes,  then
            remove  the  liquid  by  flicking  the  plate  over  a  sink.  The
            remaining drops are removed by patting the plate on a paper
            towel. Complete removal of liquid at each step is essential to
            good performance. 
              8
            5.  Add 50µl of Substrate A and 50µl of Substrate B  to each
            well. Incubate for 15 minutes at 37°C. Keeping the  plate away
            from drafts and other temperature fluctuations in the dark.
            6.  Add 50µl of Stop Solution to each well. If color change does
            not appear uniform, gently  tap  the plate  to ensure  thorough
            mixing.
            7.  Determine the optical density of each well within 30 minutes,
            using a microplate reader set to 450 nm.
            CALCULATION OF RESULTS
            Using  the  professional  soft  "Curve  Exert  1.3"  to  make  a  standard  curve  is
            recommended, which can be downloaded from our web.
            Average  the duplicate  readings  for each standard, control, and
            sample and subtract  the average zero standard optical density.
            Create  a  standard  curve  by  reducing  the  data  using  computer
            software capable of generating a  four parameter  logistic  (4-PL)
            curve-fit. As an alternative, construct a standard curve by plotting
            the mean  absorbance  for  each  standard  on  the  y-axis  against
            the concentration on the x-axis and draw a best fit curve through
            the points on  the graph. The data may be  linearized by plotting
            the log of the CRH concentrations versus the log of the O.D. and 
              9
            the best  fit  line can be determined by  regression analysis. This
            procedure will  produce  an  adequate  but  less  precise  fit  of  the
            data. If samples have been diluted, the concentration read from
            the standard curve must be multiplied by the dilution factor.
            LIMITATIONS OF THE PROCEDURE
              The kit should not be used beyond the expiration date on the
            kit label.
              Do not mix or substitute reagents with those from other lots or
            sources.
              If samples generate values higher than the highest standard,
            dilute the samples with the appropriate Diluent and repeat the
            assay.
              Any  variation  in  operator,  pipetting  technique,  washing
            technique,  incubation  time  or  temperature,  and  kit  age  can
            cause variation in binding.
              This  assay  is  designed  to  eliminate  interference  by  soluble
            receptors,  binding  proteins,  and  other  factors  present  in
            biological samples. Until all  factors have been  tested  in  the
            Quantikine  Immunoassay,  the  possibility  of  interference
            cannot be excluded. 
              10
            TECHNICAL HINTS
              Centrifuge vials before opening to collect contents.
              When mixing or reconstituting protein solutions, always avoid
            foaming.
              To  avoid  cross-contamination,  change  pipette  tips  between
            additions of each standard  level, between sample additions,
            and between reagent additions. Also, use separate reservoirs
            for each reagent.
              When using an automated plate washer, adding a 30 second
            soak  period  following  the  addition  of  wash  buffer,  and/or
            rotating  the  plate  180  degrees  between  wash  steps  may
            improve assay precision.
              To ensure accurate results, proper adhesion of plate sealers
            during incubation steps is necessary.
              Substrate Solution should remain colorless or light blue until
            added  to  the plate. Keep Substrate Solution protected  from
            light. Substrate Solution should change from colorless or light
            blue to gradations of blue. 
              11
              Stop Solution should be added to the plate in the same order
            as  the Substrate Solution. The color developed  in  the wells
            will turn from blue to yellow upon addition of the Stop Solution.
            Wells  that are green  in color  indicate  that  the Stop Solution
            has not mixed thoroughly with the Substrate Solution. 
             
             
             

            慧嘉生物您實驗身邊的好伙伴
            為客戶提供“zui高品質(zhì)的產(chǎn)品”和“zui的服務(wù)”
            AssayBiotech  CUSABIO   Immunoway  Santa   Abcam   Cst   jackson   Pierce  Sigma  Amresco  Qiagen  Cayman  abnova  millipore  invitrogen  merk  ebioscience prospec
             LifeSpan  BD 歡迎廣大客戶咨詢,另有大量宣傳海報和小禮品贈送。
            www.biohj.com  
            :382603320   1284882975

            :     

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =

            請輸驗證碼

            收藏該商鋪

            X
            該信息已收藏!
            標簽:
            保存成功

            (空格分隔,最多3個,單個標簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復您~
            撥打電話
            在線留言