狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            廈門慧嘉生物科技有限公司
            初級會員 | 第10年

            18906011628

            大鼠前列腺素E2(PGE2)ELISA試劑盒使用說明

            時(shí)間:2014/4/16閱讀:136
            分享:

            大鼠前列腺素E2(PGE2)ELISA試劑盒使用說明

            1
            Rat Prostaglandin E2(PG-E2) ELISA Kit
            Catalog Number. CSB-E07967r
            For the quantitative determination of endogenic rat prostaglandin 
            E2(PG-E2) concentrations in serum, plasma, tissue homogenates, cell 
            lysates.
            This package insert must be read in its entirety before using this product.

            In order to obtain higher efficiency service, please ready to supply the lot number 
            of the kit to us (found on the outside of the box).2
            PRINCIPLE OF THE ASSAY
            This assay employs the competitive inhibition enzyme immunoassay technique. 
            The microtiter plate provided in this kit has been pre-coated with goat-anti-rabbit 
            antibody. Standards or samples are added to the appropriate microtiter plate 
            wells with an antibody specific for  PGE2 and Horseradish Peroxidase (HRP) 
            conjugated PGE2. The competitive inhibition reaction is launched between with 
            HRP labeled PGE2 and unlabeled PGE2 with the antibody. A substrate solution 
            is added to the wells and the color develops in opposite to the amount of PGE2
            in the sample. The color development is stopped and the intensity of the color is 
            measured.
            DETECTION RANGE
            0.5 pg/ml-100 pg/ml.
            SENSITIVITY
            The minimum detectable dose of rat PGE2 is typically less than 0.25 pg/ml.
            The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as 
            the lowest rat PGE2 concentration that could be differentiated from zero. It was 
            determined the mean O.D value of 20 replicates of the zero standard added by 
            their three standard deviations.
            SPECIFICITY
            This assay has high sensitivity and excellent specificity for detection of rat PGE2. 
            No significant cross-reactivity or interference between rat PGE2 and analogues 
            was observed.
            Note: Limited by current skills and knowledge, it is impossible for us to complete 
            the cross-reactivity detection between rat PGE2 and all the analogues, therefore,
            cross reaction may still exist.3
            PRECISION
            Intra-assay Precision (Precision within an assay): CV%<15%
            Three samples of known concentration were tested twenty times on one plate to 
            assess.
            Inter-assay Precision (Precision between assays): CV%<15%
            Three samples of known concentration were tested in twenty assays to assess.
            LIMITATIONS OF THE PROCEDURE
            ? FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC 
            PROCEDURES.
            ? The kit should not be used beyond the expiration date on the kit label.
            ? Do not mix or substitute reagents with those from other lots or sources.
            ? If samples generate values higher than the highest standard, dilute the 
            samples and repeat the assay.
            ? Any variation in operator, pipetting technique, washing technique,
            incubation time or temperature, and kit age can cause variation in binding.
            ? This assay is designed to eliminate interference by soluble receptors, 
            binding proteins, and other factors present in biological samples. Until all 
            factors have been tested in the Immunoassay, the possibility of 
            interference cannot be excluded.4
            MATERIALS PROVIDED
            Reagents Quantity
            Assay plate 1(96 wells)
            Standard 6 x 0.5 ml
            Antibody    1 x 6 ml
            HRP-conjugate 1 x 6 ml
            Wash Buffer (20 x concentrate) 1 x 15 ml
            Substrate A 1 x 7 ml
            Substrate B 1 x 7 ml
            Stop Solution   1 x 7 ml
            Adhesive Strip (For 96 wells) 4
            Instruction manual 1
            STANDARD CONCENTRATION
            Standard S0 S1 S2 S3 S4 S5
            Concentration
            (pg/ml)
            0 0.5 2 8 25 100
            STORAGE
            Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date.
            Opened kit May be stored for up to 1 month at 2 - 8° C.
            *Provided this is within the expiration date of the kit.
            OTHER SUPPLIES REQUIRED
            ? Microplate reader capable of measuring absorbance at 450 nm, with the 
            correction wavelength set at 600 nm - 630 nm.
            ? An incubator which can provide stable incubation conditions up to 
            37°C±0.5°C.
            ? Squirt bottle, manifold dispenser, or automated microplate washer.
            ? Absorbent paper for blotting the microtiter plate.
            ? 100 mL and 500 mL graduated cylinders.5
            ? Deionized or distilled water.
            ? Pipettes and pipette tips.
            ? Test tubes for dilution.
            PRECAUTIONS
            The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, 
            and clothing protection when using this material.
            SAMPLE COLLECTION AND STORAGE
            ? Serum Use a serum separator tube (SST) and allow samples to clot for 
            two hours at room temperature or overnight at 4°C before centrifugation 
            for  15 minutes at 1000  ×g. Remove serum and assay immediay or 
            aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw 
            cycles.
            ? Plasma Collect plasma using EDTA, or heparin as an anticoagulant. 
            Centrifuge for 15 minutes at 1000  ×g at 2-8°C within 30 minutes of 
            collection. Assay immediay or aliquot and store samples at  -20°C or
            -80°C. Avoid repeated freeze-thaw cycles.
            ? Tissue Homogenates      100mg tissue was rinsed with 1X PBS, 
            homogenized in 1 ml of 1X PBS and stored overnight at -20°C. After two 
            freeze-thaw cycles were performed to break the cell membranes, the 
            homogenates were centrifuged for 5 minutes at  5000 x g, 2 - 8°C. The 
            supernate was removed and assayed immediay. Alternatively, aliquot 
            and store samples at -20°C or -80°C. Centrifuge the sample again after 
            thawing before the assay. Avoid repeated freeze-thaw cycles.
            ? Cell Lysates   (1) Adherent Cell: Remove media and rinse cells once 
            with ice-cold PBS (PH7.2-7.4). Scrape cells off the plate and transfer to an 
            appropriate tube. Dilute cell suspension with 1xPBS (PH7.2-7.4), until cell 
            concentration reached 100 million/ml. Then store overnight at -20°C. After 
            two freeze-thaw cycles to break up the cell membranes, the cell lysates 
            were centrifuged for 5 minutes at 5000 g, 2 - 8°C. Collect the supernatant. 
            Cell lysates should be assayed immediay or aliquotted and stored at 
            -20°C. Centrifuge the sample again after thawing before the assay. Avoid 
            repeated freeze-thaw cycles.  (2) Suspension Cell: Collect cells with 
            appropriate tube, centrifuge for 5 minutes at 1000 g, 2 - 8°C. Remove the 6
            supernatant and resuspend cells with 1xPBS (PH7.2-7.4). Centrifuge for 5 
            minutes at  1000 g, 2  - 8°C. Remove the supernatant. Dilute cell with 
            1xPBS (PH7.2-7.4), until cell concentration reached 100 million/ml. Then 
            store overnight at -20°C. After two freeze-thaw cycles to break up the cell 
            membranes, the cell lysates were centrifuged for 5 minutes at 5000 g, 2 -
            8°C. Collect the supernatant. Cell lysates should be assayed immediay 
            or aliquotted and stored at  -20°C. Centrifuge the sample again after 
            thawing before the assay. Avoid repeated freeze-thaw cycles.
            Note:
            1. CUSABIO is only responsible for the kit itself, but not for the samples 
            consumed during the assay. The user should calculate the possible 
            amount of the samples used in the whole test. Please reserve sufficient 
            samples in advance.
            2. Samples to be used within 5 days may be stored at 2-8°C, otherwise 
            samples must be stored at -20°C (≤1month) or -80°C (≤2month) to avoid 
            loss of bioactivity and contamination.
            3. Grossly hemolyzed samples are not suitable for use in this assay.
            4. If the samples are not indicated in the manual, a preliminary experiment to 
            determine the validity of the kit is necessary. 
            5. Please predict the concentration before assaying. If values for these are 
            not within the range of the standard curve, users must determine the 
            optimal sample dilutions for their particular experiments.
            6. Tissue or cell extraction samples prepared  by chemical lysis buffer may 
            cause unexpected ELISA results due to the impacts of certain chemicals.
            7. Owing to the possibility of mismatching between antigen from other 
            resource and antibody used in our kits (e.g., antibody targets 
            conformational epitope rather than linear epitope), some native or 
            recombinant proteins from other manufacturers may not be recognized by 
            our products.
            8. Influenced by the factors including cell viability, cell number and also 
            sampling time, samples from cell culture supernatant may not be detected 
            by the kit.
            9. Fresh samples without long time storage are recommended for the test. 
            Otherwise, protein degradation and denaturalization may occur in those 
            samples and finally lead to wrong results.7
            REAGENT PREPARATION
            Note: 
            ? Kindly use graduated containers to prepare the reagent. 
            ? Bring all reagents to room temperature (18-25°C) before use for 30min.
            ? Distilled water is recommended to be used to make the preparation for 
            reagents or samples. Contaminated water or container for reagent 
            preparation will influence the detection result.
            ? Wash Buffer(1x)- If crystals have formed in the concentrate, warm up to   
            room temperature and mix gently until the crystals have compley 
            dissolved. Dilute 15 ml of Wash Buffer Concentrate (20 x) into deionized 
            or distilled water to prepare 300 ml of Wash Buffer (1 x).8
            ASSAY PROCEDURE
            Bring all reagents and samples to room temperature before use. Centrifuge 
            the sample again after thawing before the assay. It is recommended that all 
            samples and standards be assayed in duplicate. 
            1. Prepare all reagents and samples as directed in the previous sections.
            2. Determine the number of wells to be used and put any remaining wells 
            and the desiccant back into the pouch and seal the ziploc, store unused 
            wells at 4°C.
            3. Set a Blank well without any solution. 
            4. Add 50μl of Standard or Sample per well. Standard need test in duplicate. 
            5. Add 50μl of  HRP-conjugate to each well (not to Blank well), then 50μl 
            Antibody to each well. Mix well and then incubate for 1 hour at 37°C. 
            6. Aspirate each well and wash, repeating the process two times for a total of 
            three washes. Wash by filling each well with Wash Buffer (200μl) using a 
            squirt bottle, multi-channel pipette, manifold dispenser, or autowasher, 
            and let it stand for 10 seconds, complete removal of liquid at each step is 
            essential to good performance. After the last wash, remove any remaining 
            Wash Buffer by aspirating ordecanting. Invert the plate and blot it against 
            clean paper towels.
            7. Add 50μl of Substrate A and 50μl of Substrate B to each well, mix well. 
            Incubate for 15 minutes at 37°C. Keeping the plate away from drafts and 
            other temperature fluctuations in the dark.
            8. Add 50μl of Stop Solution to each well, gently tap the plate to ensure 
            thorough mixing.
            9. Determine the optical density of each well within 10 minutes, using a 
            microplate reader set to 450 nm.9
            Note:
            1. The final experimental results will be closely related to validity of the 
            products, operation skills of the end users and the experimental 
            environments. 
            2. Samples or reagents addition: Please carefully add samples to wells and 
            mix gently to avoid foaming. Do not touch the well wall as possible. For 
            each step in the procedure, total dispensing time for addition of reagents 
            or samples to the assay plate should not exceed 10 minutes. This will 
            ensure equal elapsed time for each pipetting step, without interruption. 
            Duplication of all standards and specimens, although not required, is 
            recommended. To avoid cross-contamination, change pipette tips 
            between additions of each standard level, between sample additions, and 
            between reagent additions. Also, use separate reservoirs for each 
            reagent.
            3. Incubation: To ensure accurate results, proper adhesion of plate sealers 
            during incubation steps is necessary. Do not allow wells to sit uncovered
            for extended periods between incubation steps. Once reagents have been 
            added to the well strips, DO NOT let the strips DRY at any time during the 
            assay. Incubation time and temperature must be observed.
            4. Washing: The wash procedure is critical. Complete removal of liquid at 
            each step is essential to good performance. After the last wash, remove 
            any remaining Wash Solution by aspirating or decanting and remove any 
            drop of water and fingerprint on the bottom of the plate. Insufficient 
            washing will result in poor precision and falsely elevated absorbance 
            reading. When using an automated plate washer, adding a  10 second 
            soak period following the addition of wash buffer, and/or rotating the plate 
            180 degrees between wash steps may improve assay precision.
            5. Controlling of reaction time: Observe the change of color after adding 
            Substrates (e.g. observation once every 10 minutes). Substrates should 
            change from colorless or light blue to gradations of blue. If the color is too 
            deep, add Stop Solution in advance to avoid excessively strong reaction 
            which will result in inaccurate absorbance reading.
            6. Substrates are easily contaminated. Substrates should remain colorless or 
            light blue until added to the plate. Please protect it from light.
            7. Stop Solution should be added to  the plate in the same order as the 
            Substrates. The color developed in the wells will turn from blue to yellow 
            upon addition of the Stop Solution. Wells that are green in color indicate 
            that the Stop Solution has not mixed thoroughly with the Substrates.10
            ASSAY PROCEDURE SUMMARY11
            CALCULATION OF RESULTS
            Using the professional soft "Curve Expert 1.3" to make a standard curve is 
            recommended, which can be downloaded from our web.
            Average the duplicate readings for each standard and sample and subtract the 
            average optical density of Blank. 
            Create a standard curve by reducing the data using computer software capable 
            of generating a four parameter logistic (4-PL) curve-fit. As an alternative, 
            construct a standard curve by plotting the mean absorbance for each standard 
            on the x-axis against the concentration on the y-axis and draw a best fit curve 
            through the points on the graph. The data may be linearized by plotting the log of 
            the PGE2 concentrations versus the log of the O.D. and the best fit line can be 
            determined by regression analysis. This procedure will produce an adequate but 
            less precise fit of the data. 
            If samples have been diluted, the concentration read from the standard curve 
            must be multiplied by the dilution factor.

            慧嘉生物您實(shí)驗(yàn)身邊的好伙伴

            為客戶提供“zui高品質(zhì)的產(chǎn)品”和“zui的服務(wù)”

            詳細(xì)說明書及技術(shù)咨詢 

             陳

            :1193953234      1048735792

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =

            請輸驗(yàn)證碼

            收藏該商鋪

            X
            該信息已收藏!
            標(biāo)簽:
            保存成功

            (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
            撥打電話
            在線留言