            Continuous UV 254 Absorbance/Transmittance measurements can be used to protect plant treatment processes from high organic loads. Analysis range of 50mm probe is 0.01-60 m-1. Use for the following app

            Continuous UV 254 Absorbance/Transmittance measurements can be used to protect plant treatment processes from high organic loads. Analysis range of 50mm probe is 0.01-60 m-1. Use for the following applications: protection of treatment plants from industrial dischargers, monitoring shock loads from internal plant processes, control of activated sludge processes, control methanol feed in BNR based on organic loading, final effluent monitoring and monitoring efficiency of UV disinfection processes.

            • Continuous, Automatic Early Warning Systems
            • Control Activated Sludge Processes
            • Self-cleaning Wiper System
            • Monitor Efficiency of UV Disinfection Process
            • Self Diagnostics and Easy Maintenance

              Continuous, Automatic Early Warning Systems

              Use the Hach UVAS plus sc UV Absorbance/Transmittance Sensor to continuously protect plant treatment processes from high influent organic loads. Operators can use the continuous readings of UV absorbance or transmission to watch for sudden changes in organic load that would require alternate treatment procedures.

              Control Activated Sludge Processes

              Activated sludge processes require precise balancing of organic load, aeration, and nutrients. Continuous trending of the organics in the system with the UVAS plus sc sensor can help operators know how to balance other factors resulting in cost and time savings.

              Self-cleaning Wiper System

              With the UVAS plus sc sensor submerged in the sample stream, the detector windows are automatically cleaned by a built-in wiper that eliminates surface films or particles that can diminish accuracy.

              Monitor Efficiency of UV Disinfection Process

              UV light transmittance (UVT) is critical in the delivery of dose in a UV reactor. The delivered dose is determined by, among other things, the UVT of the source water, the intensity of the UV lamps, and the flow rate of the water source. UVT can be affected by many factors, from a simple change in the seasons to storm events. Potential changes in UVT should be considered in a UV disinfection system for optimized dose delivery. Hach's UVAS plus sc is designed to provide continuous UVT measurement of pre-disinfected source water. Operational costs related to sampling for UVT may be reduced with continuous online measurement. Data can immediay be incorporated into the operation in real time.

              Self Diagnostics and Easy Maintenance

              Diagnostic routines built into the UVAS plus sc sensor reduce the need for extensive calibration and maintenance. Only semi-yearly inspection and replacement of the wiper and seals is needed.

              What's in the box

              SAC probe, controller, user manual

              Specifications

              Cable Length:10 m fixed cable at sensor

              Compensation:550

              Dimensions (D x L):2.76 in x 13.11 in (70 mm x 333 mm)

              Maintenance Requirements:1 h/month in standard applications

              Measurement Method:UV absorption measurement (patented 2-beam technique)

              Measuring Interval:1 min

              Measuring Principle 2:SAC 254 in accordance with DIN 38404 C3

              Operating Temperature Range:2 to 40 °C

              Path Length:50 mm

              Pressure Limit:0.5 bar

              Service Interval:6 months

              User Maintenance:1 h/month

              Weight:7.94 lbs. (3.6 kg)

              - See more at: http://www.hach.com/uvas-sc-probe-50mm-with-sc200-controller/product-details?id=7640096678&callback=qs#sthash.Uay1qAyO.dpuf

            - See more at: http://www.hach.com/uvas-sc-probe-50mm-with-sc200-controller/product?id=7640096678&callback=qs#sthash.uhfj4fWe.dpuf