            Flow cell assembly for use with 1 NPT pH Sensors on CLF10sc and CLT10sc Chlorine Analyzers

            Exclusive Self Diagnostics
            No Reagent Replacement, No Waste Stream
            Real-Time Process Control
            Compatible with

            Exclusive Self Diagnostics

            The CLF10 sc and CLT10 sc analyzers leverage Hach's exclusive self diagnostics to alert users when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting flow sensor for notification of insufficient sample flow.

            No Reagent Replacement, No Waste Stream

            Chlorine measurement with an amperometric analyzer, such as the CLF10 sc or CLT10 sc, does not require reagents, eliminating the need for routine reagent replacement and waste stream management.

            Real-Time Process Control

            The CLF10 sc and CLT10 sc analyzers allow for real-time control of disinfection processes by providing continuous readings that indicate when treatment conditions have changed.

            Compatible with Hach's Plug and Play Digital Controllers

            The CLF10 sc and CLT10 sc analyzers can be used with any Hach sc digital controller. Whether you're measuring turbidity or chlorine, you only need to learn one controller for all your water analysis measurement points. Hach sc controllers have no complicated wiring or setup procedures. Just plug in any Hach digital sensor and it's ready to use without software configuration.

            EPA Compliant According to Method 334.0

            In accordance with EPA Method 334.0, the CLF10 sc and CLT10 sc analyzers can be used for reporting chlorine residual measurements. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required in Method 334.0. (See page 4 for a partial listing of accessories.)

            Specifications

            Accuracy:Free Chlorine: ± 3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit)

            Accuracy 2:Free Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)

            Accuracy 3:Total Chlorine: ± 10 % of the reference test* (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)

            Accuracy 4:Total Chlorine: ± 20 % of the reference test** (DPD) at stable pH greater than 8.5

            Cable Connection:5 pin, M12 connector

            Cable Length:1 m (between gateway and sc controller)

            Calibration Method:1-point or 2-point (zero and slope) calibration

            Certifications:EMC
            CE compliant for conducted and radiated emissions:
            - CISPR 11 (Class A limits)
            - EMC Immunity EN 61326-1 (Industrial limits)
            Additional certifications when connected to an sc controller

            Connection Drain Line:1/2 in OD

            Connections:1/4 in OD

            Controller Compatibility:sc controller platform

            Diameter:Sensor: 1 in ( 25 mm )

            Dimensions (H x W x D):5.9 in x 19.5 in x 19 in (151 mm x 495 mm x 483 mm)

            Interferences:Free chlorine: monochloramine, chlorine dioxide, ozone, and chalk deposits. Total chlorine: chlorine dioxide, ozone and chalk deposits

            Length:Sensor: 7.7 in ( 195 mm )

            Lower Limit of Detection (LOD):30 ppb (0.03 ppm)

            Material:Corrosion-resistant materials, fully-submersible 
            (stainless steel, PVC, silicon rubber and polycarbonate)

            Measurement Method:Reagentless, electrochemical, three-electrode amperometric system

            Measurement range:0 to 20 ppm

            Mounting:Panel or Wall Mounting

            Operating Temperature Range:0 to 45 °C

            Power Requirements (Voltage):12 V DC

            Pressure Limit:0.5 bar, no pressure impulses and/or vibrations

            Repeatability:30 ppb or 3%, whichever is greater

            Resolution:0.001 ppm (1 ppb)

            Response Time:Free Chlorine: 140 seconds or less for 90% change (T90) at a stable temperature and pH

            Sample Flow Rate:30 to 50 L/h (7.9 to 13.2 gal/hour), Optimal is 40 L/hour (10.5 gal/hour)

            Sample Temperature:5 to 45 °C (41 to 113 °F), compensated for fluctuations

            Sampling Time:Continuous

            Storage Conditions:0 to 50 °C Store chlorine sensor dry (without electrolyte)

            Temperature Compensation:Temperature compensation provided by internal temperature sensor

            Warranty:1 Year

            Weight:12.13 lbs. (5.5 kg)

            會(huì)員登錄

            請(qǐng)輸入賬號(hào)

            請(qǐng)輸入密碼

            =

            請(qǐng)輸驗(yàn)證碼

            收藏該商鋪

            標(biāo)簽:
            保存成功

            (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

            常用:

            提示

            您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
            在線留言

            會(huì)員登錄

            請(qǐng)輸入賬號(hào)

            請(qǐng)輸入密碼

            =

            請(qǐng)輸驗(yàn)證碼

            收藏該商鋪

            該信息已收藏!
            標(biāo)簽:
            保存成功

            (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

            常用: