             Measurement length 1000 mm to 4800 mm 
            ?  0,8 mm stainless steel wire diameter 
            ?  Maximum 42V Power Supply   
            ?  High strength stainless steel wire 
            ?  Potentiometric Measuring 
            Or 0-10 VDC Analog Output 
            Or 4-20 mA Current Output 
            ?  0,5 m/s maximum speed 
            ?  IP54 Protection class  
            ?  Shock/Vibration resistant  

            The AWP  series are wire potentiometric position  transducers  that 
            turn a linear motion into a resistance variation. They are made of a 
            precision  rotating  potentiometer  operated  by  a,  winding  or 
            unwinding,  stainless  steel  wire.  Optionally  other  stroke  lengths, 
            cable length and socket connector can be requested.


                                                  
             
              TECHNICAL SPECIFICATIONS 
             Power Supply  Max. 42 V 
            Stroke Length (mm) 
            1000, 2000, 3000, 4000, 4800 
            (Please ask us for other) 
            Maximum Speed  0,5 m/s 
             Resistance  5KΩ (Optional Other) 
             Output 
            Potentiometric 
            Or 0-10 VDC Analog Output 
            Or 4-20 mA Current Output 
            (Please ask us for other) 
             Linearity  ± %0,25 
             Protection Class  IP54 
             Process Temperature  - 25 to +85 °C 
             Relative Humidity  %10 to %90 
             Weight  1000 grams 
             

             
            2.  The wire encoder must be mounted vertically in position, not be horizontally.   
            3.  If there is a trickle of water (like a rain), the wire outlet must not be a drip of water upstream. If needed 
            please use guide rollers.   
            4.  The wire should not be pulled in angular. If needed, please use guide rollers. 
            1.  Do not release the wire suddenly, after pulling. 
            Guide 
            Roller 
            Guide 
            Roller 
            Failure to comply with these recommendations, the malfunctions that may occur will not be under the warranty. 
             