狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            鋼研納克檢測技術(shù)股份有限公司

            SparkCCD 7000直讀光譜分析儀在易切削鋼中的應(yīng)用

            時間:2021-3-19 閱讀:1047
            分享:

            一、 引言

            在鋼中加入一種或幾種一定數(shù)量的S、PPb、Ca、Se、Te等元素,可以改善鋼的切削加工性能,用于制作受力較小,對尺寸和粗糙度要求嚴(yán)格的儀器儀表、手表零件、汽車、機床部件,以及對尺寸精度和粗糙度要求嚴(yán)格而對力學(xué)性能要求相對較低的標(biāo)準(zhǔn)件,如齒輪、軸、螺栓、閥門、襯套、銷釘、管接頭、彈簧座墊及機床絲杠、塑料成型模具、外科和牙科手術(shù)用具等。

            但因為硫在鋼中與錳形成MnS夾雜物,采用與低合金鋼相同激發(fā)條件分析易切削鋼時,Mn的校準(zhǔn)曲線線性很差。因此,通過改變預(yù)燃時間、積分時間、積分電壓等參數(shù),改善了Mn的校準(zhǔn)曲線線性,選擇了適合易切削鋼分析的實驗條件,建立了火花直讀光譜分析易切削鋼的實驗方法。

             

            儀器配置

             

            鋼研納克SparkCCD7000型火花直讀光譜儀

             

               SparkCCD 7000 全譜直讀光譜儀可廣泛應(yīng)用于冶金、鑄造、機械、鋼鐵和有色金屬等行業(yè),在汽車制造、航空航天、船舶、機電設(shè)備、工程機械、電子電工、教育、科研等領(lǐng)域的原料、零件、產(chǎn)品工藝研發(fā)方面都有廣泛的應(yīng)用??捎糜?/font> Fe、Al、CuNi、CoMg、Ti、Zn、PbSn、Mn 等金屬及其合金的樣品分析。

                SparkCCD 7000全譜火花直讀光譜儀采用高分辨率線陣CCDCharge-coupled Device)作為檢測器,實現(xiàn)全譜掃描。采用智能控制光室充氣系統(tǒng),儀器性能更 穩(wěn)定,服務(wù)期限更長久。海量的譜線使分析不再受限,曲 線分段跳轉(zhuǎn)同一元素不同譜線間實現(xiàn)無縫銜接,拓展分析 范圍第三元素干擾校正使元素分析更加準(zhǔn)確,可以在用戶 現(xiàn)場任意增加材料基體和分析元素而無需增加硬件,維護 保養(yǎng)方便。能量、頻率連續(xù)可調(diào)全數(shù)字固態(tài)光源,適應(yīng)各 種不同材料;網(wǎng)口采集傳輸,速度快,通用性更強。

             

            二、 結(jié)果與討論

            2.1 校準(zhǔn)曲線

            激發(fā)條件選定為充氣時間10s,預(yù)燃時間35s,積分時間5s,激發(fā)頻率500Hz,預(yù)燃電壓0.5,積分電壓0.15,氬氣流量8L/min,方法中的各元素所用分析譜線及參比譜線、線性范圍、線性相關(guān)系數(shù)列于表1中。

            1 各元素譜線選擇及其線性相關(guān)系數(shù)

            元素

            分析線波長/nm

            參比線波長/nm

            線性范圍/%

            線性相關(guān)系數(shù),R2

            C

            193.1

            187.7

            0.0098~0.39

            0.99755

            Si

            288.1

            282.3

            0.019~0.477

            0.99901

            Mn

            293.3

            283.2

            0.6~1.84

            0.99559

            P

            178.3

            194.7

            0.007~0.0778

            0.99776

            S

            180.7

            194.7

            0.097~0.38

            0.99806

            Cr

            267.7

            258.2

            0.017~0.568

            0.99961

            Ni

            231.6

            223.3

            0.0205~0.25

            0.99964

            Mo

            281.6

            282.3

            0.012~0.287

            1.00000

            Cu

            327.4

            328.7

            0.0056~0.25

            0.99986

            V

            311.0

            308.4

            0.002~0.0359

            1.00000

            Al

            396.1

            392.2

            0.002~0.032

            0.99140

            2.2精密度實驗

            按照2.1中選定的實驗條件,在繪制的校準(zhǔn)曲線下激發(fā)IMZ-122標(biāo)樣10點,所得測試結(jié)果列于表2中。

            2 穩(wěn)定性測試結(jié)果(%,n=10

            元素

            測試值

            平均值

            標(biāo)準(zhǔn)偏差

            RSD%

            C

            0.309,0.305,0.305,0.306,0.304,0.305,0.304,0.308,0.305,0.305

            0.3056

            0.00165

            0.54

            Si

            0.452,0.452,0.452,0.454,0.450,0.453,0.454,0.452,0.451,0.451

            0.4521

            0.00129

            0.28

            Mn

            1.309,1.316,1.298,1.311,1.295,1.309,1.306,1.314,1.308,1.302

            1.3068

            0.00671

            0.51

            P

            0.065,0.066,0.067,0.066,0.067,0.066,0.068,0.066,0.065,0.068

            0.0664

            0.00107

            1.62

            S

            0.168,0.175,0.172,0.175,0.174,0.171,0.174,0.176,0.174,0.171

            0.173

            0.00245

            1.42

            Cr

            0.178,0.179,0.179,0.179,0.179,0.179,0.180,0.179,0.179,0.179

            0.179

            0.00047

            0.26

            Ni

            0.240,0.239,0.236,0.238,0.235,0.238,0.237,0.238,0.237,0.238

            0.2376

            0.00143

            0.60

            Mo

            0.018,0.018,0.018,0.018,0.018,0.018,0.017,0.018,0.018,0.019

            0.018

            0.00047

            2.62

            Cu

            0.246,0.246,0.246,0.245,0.247,0.245,0.245,0.247,0.246,0.247

            0.246

            0.00082

            0.33

            V

            0.004,0.004,0.004,0.004,0.004,0.004,0.004,0.004,0.004,0.004

            0.004

            /

            /

            Al

            0.025,0.026,0.026,0.026,0.026,0.025,0.025,0.025,0.025,0.026

            0.0255

            0.00032

            1.26

            2.3正確度實驗

            按照2.1中選定的實驗條件,在繪制的校準(zhǔn)曲線下測試BS 66B、IARM 206AIARM 29c三塊標(biāo)樣,所得測試結(jié)果及標(biāo)樣參考值列于表3中。由表3可見,本方法測試結(jié)果與參考值一致性較好。

            3 易切削鋼標(biāo)樣測試結(jié)果(%

            元素

            BS 66B

            IARM 206A

            IARM 29c

            測定值

            參考值

            測定值

            參考值

            測定值

            參考值

            C

            0.429

            0.418

            0.068

            0.068

            0.182

            0.180

            Si

            0.020

            0.020

            0.017

            0.019

            0.289

            0.280

            Mn

            1.575

            1.560

            0.910

            0.900

            1.186

            1.200

            P

            0.018

            0.018

            0.070

            0.069

            0.008

            0.011

            S

            0.130

            0.112

            0.256

            0.260

            0.128

            0.130

            Cr

            0.093

            0.093

            0.041

            0.041

            0.075

            0.076

            Ni

            0.032

            0.032

            0.045

            0.044

            0.077

            0.075

            Mo

            0.023

            0.019

            0.010

            0.012

            0.014

            0.016

            Cu

            0.029

            0.028

            0.100

            0.098

            0.152

            0.150

            V

            0.0028

            0.0014

            0.0018

            0.002

            0.0028

            0.003

            Al

            0.0018

            0.002

            0.0021

            0.003

            0.0021

            0.003

            三、 實驗結(jié)論

            通過考察光譜預(yù)燃時間、積分時間、積分電壓等激發(fā)參數(shù)與易切削鋼中Mn的校準(zhǔn)曲線線性相關(guān)系數(shù)的關(guān)系,找到了適合易切削鋼分析的激發(fā)條件,建立了火花光譜分析易切削鋼的實驗方法,運用本方法分析易切削鋼標(biāo)樣,測試結(jié)果與參考值一致性較好,各元素的相對標(biāo)準(zhǔn)偏差(RSD%)在0.26~2.62之間。該方法適用于易切削鋼生產(chǎn)、使用單位快速分析及質(zhì)量控制需要。

             

            四、 
            鋼研納克其余直讀光譜儀產(chǎn)品均可達(dá)到此效果


             

             

            SparkCCD6500  全譜火花直讀光譜儀           Labspark 1000  精密火花直讀光譜儀

             

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =

            請輸驗證碼

            收藏該商鋪

            X
            該信息已收藏!
            標(biāo)簽:
            保存成功

            (空格分隔,最多3個,單個標(biāo)簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復(fù)您~
            撥打電話 產(chǎn)品分類
            在線留言