            美國ChemTracCRA3500氯殘留分析儀

            詳細介紹

            美國ChemTracCRA3500氯殘留分析儀

            CHLORINE RESIDUAL ANALYZER
            Reagentless Chlorine Residual Analyzers including a Free Cl2 Analyzer, Total (Combined) Chlorine Analyzer, and Chlorine Dioxide Analyzer.   It is now possible to use the CRA3500’s Membrane Covered Three-Electrode Free and Total Chlorine Sensors for compliance monitoring in drinking water (see below note for more details).  Chemtrac’s Residual Chlorine Analyzer, in conjunction with a wide range of On-line Residual Chlorine Sensors, utilizes state of the art electronics that can include PID control, internal datalogging, local trending of recorded values on graphical display, Modbus TCP communications, Test Messaging of alarms, plus many other features. 
            The Residual Cl2 sensors that work with the CRA3500 Chlorine Meter do not require the use of external buffers or reagents which can present disposal issues.  These membrane covered probes are unique in that they are internally buffered, which greatly improves their reliability and accuracy as compared to traditional amperometric chlorine analyzers.    With maintenance intervals of just 3 to 6 months on the Free, Total (Combined), and Chlorine Dioxide Analyzers; these Bufferless and Reagentless Chlorine Meters are fast becoming the instrument of choice for the customer who wants the best chlorine sensor at the best price.
            The CRA3500 Chlorine Residual Analyzer offers a wide array of communication & integration options including TCP/IP (LAN), RS485, USB, TTL, Relays, 4-20mA outputs, and GSM/GPRS modem.  It is possible to interface and control the CRA3500 Chlorine Meter remoy, enabling data, alarms, and setup information directly from your computer.  Despite all the additional functionality that this instrument has to offer, the purchase cost are less than, or comparable to, its competitors.  Factor in that there is no requirement for reagents or buffers, and that there are no moving parts to replace or maintain, and the payback period to replace an existing residual Cl2 analyzer could be just a few months.

             

            BENEFITS
            Automatic Calibration
            Low Purchase Cost
            Low Cost of Ownership
            Reduced pH Dependency
            SMS Text Alarms
            Webserver*
            Bluetooth
            4-20mA and Relay Outputs
            Carbon Dioxide or Acid Buffer if Required
            Can Operate for Three Months
            without Operator Intervention
            APPLICATIONS
            WATER TREATMENT
            Remote sites
            Automatic Calibration
            Chlorine Dosing Control
            Secondary Chlorination

            INLET/OUTLET MONITORING
            Surface Water Inlet
            Surface Water Outlet
            Process Water Monitoring
            DESCRIPTION OF OPERATION
            The membraned polarographic probe, is enhanced with a third, reference, electrode which eliminates zero drift. pH correction is often not required at all. Where it is required there are options for using carbon dioxide or a more traditional acid buffer. A Total Residual Chlorine measurement probe option is also available.

            The CRA 3500 offers a vast array of communication protocols including Bluetooth, TCP/IP (with webserver), USB, RS485, TTL, Relays and 4-20mA outputs. It is possible to interface and control the CRA 3500 remoy, enabling data, alarms and setup information to be sent directly to your computer, PDA or phone.

             

            ANALYZER SPECIFICATIONS
            Power:
            110-240 VAC
            Display:
            LCD Backlit 128x64 graphical
            Outputs:
            2 configurable alarms (relays)
             
            2 - 4-20mA outputs
            Inputs:
            1 low flow alarm
             
            1 low buffer alarm
            Comms:
            Bluetooth
             
            RS485
             
            TCP/IP (Webserver)
            Datalogging:
            One year at 15 min. intervals (equiv.)
            Eventlogging
            500 events
            AUTOCALIBRATOR
            Power:
            110 VAC
            Outputs:
            Low flow alarm
             
            Low Co2 alarm (if fitted)
            Co2 pH Suppressant Unit (If Required)
            Co2 Usage:
            Variable, zero waste
            Acid Buffer Unit (If Required)
            Power:
            110 VAC
            Dosing Pump:
            Peristaltic

             
            CHLORINE SENSOR PROBE SPECIFICATIONS
            Type:
            Membrane covered amperometric polarographic three-electrode system
            Measured:
            Free Residual Chlorine or Total Residual Chlorine
            Range:
            0-1, 0-2, 0-5, 0-10, 0-20mg/l (ppm)
            Resolution:
            0.01mg/l (ppm)
            Reproducibility:
            ±5%
            Stability:
            -2% per month (without calibration)
            Working electrode:
            Cathode made of gold
            Counter electrode:
            Anode made of stainless steel
            Reference electrode:
            Silver / silver halide
            Membrane material:
            Micro-porous hydrophillic membrane
            Flow Rate:
            Approximay 0.5l/min.
            Temperature range:
            >0 up to 40 °C
            Temperature compensation:
            Automatically by an integrated thermistor
            pH - range:
            pH 4 up to pH 9,5
            Permissible overpressure:
            0.5 bar
            First-polarization time:
            120 min.
            Re-polarization time:
            30 min.
            Zero-point adjustment:
            Not necessary
            Calibration:
            Manual using DPD or Automatic
            Housing material:
            PVC, silicone, polycarbonate stainless
            Dimensions:
            Diameter approx. 25mm, length 175mm
            Maintenance intervals:
             
            Membrane:
            Yearly
            Electrolyte:
            Quarterly
            Calibration reagent:
            Quarterly
            Interferences:
            High levels of other oxidants such as Ozone and Chlorine Dioxide