            Human IL-3 ELISA Kit

            時間:2015-10-22閱讀:876
            分享:

            Human IL-3 ELISA Kit

            *: [96T/48T] 
            #: It’s OK to keep the kit in 4℃, if the kit is scheduled to be used up in one week. Please keep the 
            reagent in -20℃ for long-term storage or repeated use. 
            The reagent in each vial is slightly more that its volume written on label, please take out the required 
            volume by certain tools (such as transferpettor, measuring cylinder), rather than pouring directly. 
             Human IL-3 ELISA Kit
            Test principle 
            This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has 
            been pre-coated with an antibody specific to Human IL-3. Standards or samples are then added to the 
            appropriate micro ELISA plate wells and combined to the specific antibody. Then a biotinylated 
            detection antibody specific for Human IL-3 and Avidin-Horseradish Peroxidase (HRP) conjugate is 
            added to each micro plate well and incubated. Free components are washed away. The substrate 
            solution is added to each well. Only those wells that contain Human IL-3, biotinylated detection 
            antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is 
            terminated by the addition of a sulphuric acid solution and the color turn yellow. The optical density 
            (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is  
            Human IL-3 ELISA Kit

            proportional to the concentration of Human IL-3. You can calculate the concentration of IL-3 in the 
            samples by comparing the OD of the samples to the standard curve. 
             
            Sample collection and storage 
            Serum - Allow samples to clot for 2 hours at room temperature or overnight at 4°Cbefore 
            centrifugation for 20 minutes at approximay 1000×g. Collect the supernatant and carry out the 
            assay immediay. Blood collection tubes should be disposable, non-pyrogenic, and non-endotoxin. 
             
            Plasma - Collect plasma using EDTA-Na2 or heparin as an anticoagulant. Centrifuge samples for 15 
            minutes at 1000×g at 2 - 8°C within 30 minutes of collection. Collect the supernatant and carry out 
            the assay immediay. Avoid hemolysis, high cholesterol samples. 
             
            Tissue homogenates– For general information, hemolysis blood may affect the result, so you should 
            rinse the tissues with ice-cold PBS (0.01M, pH=7.4) to remove excess blood thoroughly. Tissue 
            pieces should be weighed and then minced to small pieces which will be homogenized in PBS (the 
            volume depends on the weight of the tissue. 9mL PBS would be appropriate to 1 gram tissue pieces. 
            Some protease inhibitor is recommended to add into the PBS.) with a glass homogenizer on ice. To 
            further break the cells, you can sonicate the suspension with an ultrasonic cell disrupter or subject it to 
            freeze-thaw cycles. The homogenates are then centrifugated for 5minutes at 5000×g to get the 
            supernate. 
             
            Cell culture supernate – Centrifuge supernate for 20 minutes to remove insoluble impurity and cell 
            debris at 1000×g at 2 - 8°C. Collect the clear supernate and carry out the assay immediay. 
             
            Other biological fluids –Centrifuge samples for 20 minutes at 1000×g at 2 - 8°C. Collect the 
            supernatant and carry out the assay immediay. (You can refer to our website for detailed processing 

            Sample preparation – Samples should be clear and transparent and be centrifuged to remove 
            suspended solids. 
            Note: Serum and plasma to be used within 7 days when stored at 2-8°C, otherwise samples must be 
            divided and stored at -20°C (≤1 month) or -80°C (≤6 months) to avoid loss of bioactivity and 
            contamination. Avoid freeze-thaw cycles. When performing the assay slowly bring samples to room 
            temperature. If the sample concentration is higher than the maximum standard value, please dilute it 
            with appropriate factor according to the actual situation. (A pre-test is recommended to determine the 
            dilute factor). 
             
            Other supplies required  

            Microplate reader with 450nm wavelength filter 
            High-precision transferpettor, EP tubes and disposable pipette tips 
            37°C Incubator, Deionized or distilled water 
            Absorbent paper 
             
            Reagent preparation 
            Bring all reagents to room temperature before use. 
            Wash Buffer - Dilute 30mL of Concentrated Wash Buffer into 750 mL of Wash Buffer with deionized 
            or distilled water. Put unused solution back at 4°C. If crystals have formed in the concentrate, you can 
            warm it with 40°Cwater bath (Heating temperature should not exceed 50°C) and mix it gently until the 
            crystals have compley dissolved. The solution should be cooled to room temperature before use. 
            Standard- Centrifuge at 10,000×g for 1 minute, and reconstitute the Standard with 1.0mL of 
            Reference Standard &Sample Diluent. Tighten the lid, let it stand for 10 minutes and turn it upside 
            down for several times. After it dissolves fully, mix it thoroughly with a pipette. This reconstitution 
            produces a stock solution of 1000pg/mL. Then make serial dilutions as needed (Making serial 
            dilution in the wells directly is not permitted). The recommended concentrations are as follows:1000、
            500、250、125、62.5、31.25、15.625、0pg/mL . As if you want to make standard solution at the 
            concentration of 500pg/mL, you can take 0.5mL the standard at 1000pg/mL, add it to an EP tube with 
            0.5mL Reference Standard &Sample Diluent, and mix it. The procedures of making the remaining 
            concentrations are all the same. The undiluted standard serves as the highest standard (1000pg/mL). 
            The Reference Standard &Sample Diluent serves as the zero (0pg/mL). 
            (500μL/tube,for example. Can also be diluted according to the actual amount,such as 200μL/tube) 