狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            產(chǎn)品推薦:氣相|液相|光譜|質譜|電化學|元素分析|水分測定儀|樣品前處理|試驗機|培養(yǎng)箱


            化工儀器網(wǎng)>技術中心>解決方案>正文

            歡迎聯(lián)系我

            有什么可以幫您? 在線咨詢

            Human Japanese Encephalitis JE IgG

            來源:北京索萊寶科技有限公司   2010年07月22日 11:04  

            FOR RESEARCH USE ONLY

            Assay range30ng/ml -800ng/ml                      96 determinations

            Purpose

            This kit allows for the determination of  JE IgG concentrations in Human serum, cell culture supernates and other biological fluids

             

            Principle of the assay

            The kit assay Human JE IgG level in the sample,use Purified Human JE IgG antigen to coat microtiter plate wells, make solid-phase antigen, then add Human JE IgG antibody to wells, Combined antigen which With HRP labeled goat anti- Human become antigen - antigen - enzyme- antigen complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of  Human JE IgG antibody in the samples is then determined by comparing the O.D. of the samples to the standard curve.

            Materials provided with the kit

            1

            wash  solution

            20ml×1bottle

            7

            Stopp Solution

            6ml×1 bottle

            2

            HRP-Conjugate reagent

            6ml×1 bottle

            8

            Standard1600ng/ml

            0.5ml×1 bottle

            3

            Microelisa stripplate

            12well×8strips

            9

            Standard diluent

            1.5ml×1bottle

            4

            Sample diluent

            6ml×1 bottle

            10

            Instruction

            1

            5

            Chromogen Solution A

            6ml×1 bottle

            11

            Closure plate membrane

            2

            6

            Chromogen Solution B

            6ml×1 bottle

            12

            Sealed bags

            1

            Specimen requirements

            1.       extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 to preserve, Avoid repeated freeze-thaw cycles.

            2.       Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

            Assay procedure

            1.       Dilute and add sample:Dilute Original density Standard as follow table:

            800ng/ml

            5 Standard

            150μl Original density Standard+150μl Standard diluent

            400ng/ml

            4 Standard

            150μl 5 Standard+150μl Standard diluent

            200ng/ml

            3 Standard

            150μl 4 Standard+150μl Standard diluent

            100ng/ml

            2 Standard

            150μl 3 Standard +150μl Standard diluent

            50ng/ml

            1 Standard

            150μl 2 Standard +150μl Standard diluent

            2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

            3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.

            4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.

            5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

            6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well.

            7.incubateOperation with 3.

            8.washingOperation with 5.

            9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37

            10.Stop the reactionAdd Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).

            11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

            Steps description

            Standard, Sample diluent

             

            Add Standard, Sample diluent, incubate for 30 min at 37.

             

            Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

             

            Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37.

             

            Add Stopp Solution

             

            Read absorbance at 450nm within 15 min

             

            calculate

            Calculate

            Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.

            Important notes

            1.       The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

            2.       washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

            3.       add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

            4.       if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

            5.       Closure plate membrane only limits the disposable use, to avoid cross-contamination.

            6.       The substrate evade the light preservation.

            7.       Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

            8.       All samples, washing buffer and each kind of reject should according to infective material process.

            9.       Do not mix reagents with those from other lots.

             

            Storage and validity

            1Storage  2-8.

            2validity six months.

             

             