脂蛋白a(Lpa)檢測試劑盒
適用生物 Homo sapiens (Human,人)
檢測范圍 3.13-200ng/mL 靈敏度 1.48ng/mL
樣本類型 Serum, plasma, tissue homogenates and other biological fluids.
實驗時長 4.5h 實驗方法 雙抗夾心法
脂蛋白a(Lpa)檢測試劑盒 規(guī)格 96T
ELISA Kit for Lipoprotein, a (Lpa)
FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!
Organism species Homo sapiens (Human)
Product No. SEA842Hu
Sample type Serum, plasma, tissue homogenates and other biological fluids.
Format 96-well strip plate
Assay length 4.5 hours
Detection range 3.13-200ng/mL The standard curve concentrations used for the ELISA’s were 200ng/mL, 100ng/mL, 50ng/mL, 25ng/mL, 12.5ng/mL, 6.25ng/mL, 3.13ng/mL
Sensitivity The minimum detectable dose of this kit is typically less than 1.48ng/mL.
脂蛋白a(Lpa)檢測試劑盒 Specificity
This assay has high sensitivity and excellent specificity for detection of Lipoprotein, a (Lpa).
No significant cross-reactivity or interference between Lipoprotein, a (Lpa) and analogues was observed. Recovery
Matrices listed below were spiked with certain level of recombinant Lipoprotein, a (Lpa) and the recovery rates were calculated by comparing the measured value to the expected amount of Lipoprotein, a (Lpa) in samples.
Matrix Recovery range (%) Average(%)
serum(n=5) 91-104 97
EDTA plasma(n=5) 99-105 102
heparin plasma(n=5) 85-101 90
脂蛋白a(Lpa)檢測試劑盒 Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lipoprotein, a (Lpa) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lipoprotein, a (Lpa) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
脂蛋白a(Lpa)檢測試劑盒 Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lipoprotein, a (Lpa) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 90-103% 89-101% 88-98%
EDTA plasma(n=5) 90-97% 88-102% 85-95% 83-97%
heparin plasma(n=5) 98-105% 88-102% 94-102% 86-94%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. Reagents and materials provided
Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B 1×120μL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1
脂蛋白a(Lpa)檢測試劑盒 Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100μL standard or sample to each well. Incubate 2 hours at 37oC;
3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37oC;
4. Aspirate and wash 3 times;
5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
6. Aspirate and wash 5 times;
7. Add 90μL Substrate Solution. Incubate 15-25 minutes at 37oC;
8. Add 50μL Stop Solution. Read at 450nm immediay.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Lipoprotein, a (Lpa). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Lipoprotein, a (Lpa). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Lipoprotein, a (Lpa), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Lipoprotein, a (Lpa) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
免責聲明
- 凡本網(wǎng)注明“來源:化工儀器網(wǎng)”的所有作品,均為浙江興旺寶明通網(wǎng)絡有限公司-化工儀器網(wǎng)合法擁有版權或有權使用的作品,未經(jīng)本網(wǎng)授權不得轉載、摘編或利用其它方式使用上述作品。已經(jīng)本網(wǎng)授權使用作品的,應在授權范圍內(nèi)使用,并注明“來源:化工儀器網(wǎng)”。違反上述聲明者,本網(wǎng)將追究其相關法律責任。
- 本網(wǎng)轉載并注明自其他來源(非化工儀器網(wǎng))的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點和對其真實性負責,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網(wǎng)站或個人從本網(wǎng)轉載時,必須保留本網(wǎng)注明的作品第一來源,并自負版權等法律責任。
- 如涉及作品內(nèi)容、版權等問題,請在作品發(fā)表之日起一周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關權利。