            豬(IL-6)豬白介素6(IL-6)ELISA試劑盒說明書

            時間:2011/9/27閱讀:452
            分享:

            ----------------------- Page 1-----------------------

                   Porcine Interleukin 6 (IL-6)

                                        ELISA Kit

             

                                  Catalog No. CSB-E06786p

             

                                                (96T)

             

            ?   This immunoassay kit allows for the in vitro quantitative determination of porcine

             

                IL-6 concentrations in serum, plasma.

             

            ?   Expiration date   six months from the date of manufacture

             

            ?   FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.

             

                                                   1


            ----------------------- Page 2-----------------------

            INTRODUCTION

             

            Interleukin-6 (IL-6) is a protein that in humans is encoded by the

             

            IL6     gene.    IL-6    is  an    interleukin    that   acts    as   both    a

             

            pro-inflammatory   and   anti-inflammatory   cytokine.   It   is   secreted

             

            by   T   cells   and   macrophages   to stimulate   immune   response   to

             

            trauma,     especially    burns   or  other    tissue  damage      leading    to

             

            inflammation. In terms of host response to a foreign pathogen,

             

            IL-6   has   been   shown,   in   mice,  to   be   required   for   resistance

             

            against the bacterium, Streptococcus pneumoniae. IL-6 is also a

             

            "myokine," a cytokine produced from muscle, and is elevated in

             

            response to muscle contraction. It is significantly elevated with

             

            exercise, and precedes the appearance of other cytokines in the

             

            circulation. During exercise, it is thought to act in a hormone-like

             

            manner      to  mobilize    extracellular    substrates     and/or   augment

             

            substrate delivery (Petersen, J Appl Physiol 2005). Additionally,

             

            osteoblasts      secrete    IL-6   to   stimulate    osteoclast     formation.

             

            Smooth muscle cells in the tunica media of many blood vessels

             

            also produce IL-6 as a pro-inflammatory cytokine. IL-6's role as

             

            an anti-inflammatory cytokine is mediated through its inhibitory

             

            effects on TNF-alpha and IL-1, and activation of IL-1ra and IL-10.

             

                                                   2


            ----------------------- Page 3-----------------------

            IL-6 is one of the most important mediators of fever and of the

             

            acute phase response. It is capable of crossing the blood brain

             

            barrier   and   initiating   synthesis   of   PGE2   in   the   hypothalamus,

             

            thereby changing the body's temperature setpoint. In the muscle

             

            and fatty tissue IL-6 stimulates energy mobilization which leads

             

            to   increased      body    temperature.      IL-6   can   be   secreted     by

             

            macrophages         in  response      to  specific    microbial    molecules,

             

            referred to as pathogen associated molecular patterns (PAMPs).

             

            IL-6 is also essential for hybridoma growth and is found in many

             

            supplemental cloning media such as briclone. Inhibitors of IL-6

             

            (including      estrogen)     are    used     to   treat    postmenopausal

             

            osteoporosis. Il-6 is also produced by adipocytes and is thought

             

            to be a reason why obese individuals have higher endogeneous

             

            levels   of   CRP.   In   a   2009   study,   intranasally   administered   IL-6

             

            was     shown      to   improve     sleep-associated       consolidation      of

             

            emotional memories.

             

            PRINCIPLE OF THE ASSAY

             

            The microtiter plate provided in this kit has been pre-coated with

             

            an   antibody   specific   to   IL-6. Standards   or   samples   are   then

             

                                                   3


            ----------------------- Page 4-----------------------

            added to the appropriate microtiter plate wells with a Horseradish

             

            Peroxidase (HRP)-conjugated monoclonal antibody preparation

             

            specific for IL-6 and incubated. Then substrate solution A and B

             

            are    added    to  each   well.  Only   those   wells   that  contain   IL-6,

             

            HRP-conjugated   antibody   will   exhibit   a   change   in   color.   The

             

            enzyme-substrate   reaction   is   terminated   by   the   addition   of   a

             

            sulphuric     acid   solution   and    the  color   change     is  measured

             

            spectrophotometrically at a wavelength of 450 nm ± 2 nm. The

             

            concentration      of  IL-6  in  the  samples     is  then   determined     by

             

            comparing the O.D. of the samples to the standard curve.

             

            DETECTION RANGE

             

            The standard curve concentrations used for the ELISA’s were 80

             

            pg/ml, 40 pg/ml, 20 pg/ml, 10 pg/ml, 4 pg/ml, 2pg/ml.

             

            SPECIFICITY

             

            This assay recognizes recombinant and natural porcine IL-6. No

             

            significant cross-reactivity or interference was observed.

             

                                                  4


            ----------------------- Page 5-----------------------

            SENSITIVITY

             

            The   minimum   detectable   dose   of  porcine   IL-6   is   typically   less

             

            than   1   pg/ml.   The   sensitivity   of  this   assay,   or   Lower   Limit   of

             

            Detection   (LLD)   was   defined   as   the   lowest   concentration   that

             

            could be differentiated from zero.

             

            MATERIALS PROVIDED

             

                          Reagent                          Quantity

             

                          Assay plate                           1

             

                          Standard(S  -S  )                    6

                                        1   6

             

                          HRP-conjugate                     1 x 6 ml

             

                                                           1 x 15 ml

                          Wash Buffer

                                                       (20×concentrate)

             

                          Substrate A                       1 x 6 ml

             

                          Substrate B                       1 x 6 ml

             

                          Stop Solution                     1x 6 ml

             

                     Standard               S1      S2      S3       S4      S5      S6

             

             Concentration (pg/ml)          2        4      10       20      40      80

             

                                                  5


            ----------------------- Page 6-----------------------

            STORAGE

             

            1.  Unopened   test   kits   should   be   stored   at   2-8?C   upon   receipt

             

                and the microtiter plate should be kept in a sealed bag. The

             

               test kit may be used throughout the expiration date of the kit,

             

                provided     it  is  stored  as   prescribed    above.     Refer   to  the

             

                package label for the expiration date.

             

            2.   Opened test plate should be stored at 2-8?C in the aluminum

             

               foil bag with desiccants to minimize exposure to damp air. The

             

                kits will remain stable until the expiring date shown, provided it

             

                is stored as prescribed above.

             

            3.  A  microtiter   plate   reader   with   a   bandwidth   of   10   nm   or   less

             

                and an optical density range of 0-3 OD or greater at 450nm

             

               wavelength         is   acceptable       for    use     in    absorbance

             

                measurement.

             

            REAGENT PREPARATION

             

            1.  Bring all reagents and plate to room temperature for at least

             

                30 minutes before use. Unused wells need store at 2-8°C and

             

                avoid sunlight.

             

                                                  6


            ----------------------- Page 7-----------------------

            2.  Wash   Buffer       If   crystals   have   formed   in   the   concentrate,

             

               warm   to   room   temperature   and   mix   gently   until   the   crystals

             

                have    compley     dissolved.    Dilute   15  ml   of  Wash     Buffer

             

                Concentrate into deionized or distilled water to prepare 300 ml

             

                of Wash Buffer.

             

            Precaution: The Stop Solution provided with this kit is an acid solution. Wear

             

                       eye, hand, face, and clothing protection when using this material.

             

            OTHER SUPPLIES REQUIRED

             

            ?  Microplate reader capable of measuring absorbance at 450

             

                nm, with the correction wavelength set at 540 nm or 570 nm.

             

            ?  Pipettes and pipette tips.

             

            ?  Deionized or distilled water.

             

            ?  Squirt bottle, manifold dispenser, or automated microplate

             

                washer.

             

            ?  An incubator which can provide stable incubation conditions

             

                up to 37°C±0.5°C.

             

            SAMPLE COLLECTION AND STORAGE

             

            ?   Serum       Use     a  serum     separator    tube   (SST)    and    allow

             

                                                  7


            ----------------------- Page 8-----------------------

                 samples   to   clot   for   30   minutes   before   centrifugation   for   15

             

                 minutes at 1000 g. Remove serum and assay immediay or

             

                 aliquot   and   store   samples   at  -20°C.   Centrifuge   the   sample

             

                 again     after    thawing     before    the    assay.     Avoid     repeated

             

                freeze-thaw cycles.

             

            ?    Plasma       Collect plasma using citrate, EDTA, or heparin as

             

                 an anticoagulant. Centrifuge for  15 minutes at 1000 g within

             

                 30   minutes   of   collection.   Assay   immediay   or   aliquot   and

             

                 store   samples   at   -20°C.   Centrifuge   the   sample   again   after

             

                 thawing before the assay. Avoid repeated freeze-thaw cycles.

             

            Note: Grossly hemolyzed samples are not suitable for use in this assay.

             

            ASSAY PROCEDURE

             

            Bring    all  reagents  and   samples   to  room   temperature    before   use.  It  is

             

            recommended that all samples, standards, and controls be assayed in duplicate.

             

            All   the   reagents   should   be   added   directly   to   the  liquid   level   in   the   well.   The

             

            pipette should avoid contacting the inner wall of the well.

             

            1.   Set a Blank well without any solution. Add 100μl of Standard

             

                 or Sample per well. Standard need test in duplicate.

             

            2.   Add 50μl of HRP-conjugate to each well (not to Blank well).

             

                 Mix well and then incubate for 2 hours at 37°C.

             

                                                      8


            ----------------------- Page 9-----------------------

            3.   Complete   remove   the   liquid.   Then   fill   each   well   with  Wash

             

                Buffer   (about      200μl),   stay   for  10   seconds     and   Spinning.

             

                Repeat   the   process   for   a   total  of   three   washes.   Complete

             

                removal       of   liquid   at  each     step    is  essential     to   good

             

                performance.        After  the   last  wash,    remove     any   remaining

             

                Wash Buffer by aspirating or decanting. Invert the plate and

             

                blot it against clean paper towels.

             

            4.   Add 50μl of Substrate A and 50μl of Substrate B to each

             

                well, mix well. Incubate for 15 minutes at 37°C. Keeping the

             

                plate away from drafts and other temperature fluctuations in

             

                the dark.

             

            5.   Add 50μl of Stop Solution to each well. If color change does

             

                not appear uniform, gently tap the plate to ensure thorough

             

                mixing.

             

            6.   Determine the optical density of each well within 10 minutes,

             

                using a microplate reader set to 450 nm.

             

            CALCULATION OF RESULTS

             

            Using   the   professional   soft   "Curve   Exert 1.3"   to   make   a   standard   curve   is

            recommended, which can be downloaded from our web.

             

            Average the duplicate readings for each standard, control, and

             

                                                    9


            ----------------------- Page 10-----------------------

            sample and subtract the average zero standard optical density.

             

            Create   a   standard   curve   by   reducing   the   data   using   computer

             

            software capable of generating a four parameter logistic (4-PL)

             

            curve-fit. As an alternative, construct a standard curve by plotting

             

            the   mean   absorbance   for   each  standard   on   the   y-axis   against

             

            the concentration on the x-axis and draw a best fit curve through

             

            the points on the graph. The data may be linearized by plotting

             

            the log of the IL-6 concentrations versus the log of the O.D. and

             

            the best fit line can  be determined by regression analysis. This

             

            procedure   will   produce   an  adequate   but   less   precise   fit   of   the

             

            data. If samples have been diluted, the concentration read from

             

            the standard curve must be multiplied by the dilution factor.

             

            LIMITATIONS OF THE PROCEDURE

             

            ?  The kit should not be used beyond the expiration date on the

             

                kit label.

             

            ?  Do not mix or substitute reagents with those from other lots or

             

                sources.

             

            ?  If samples generate values higher than the highest standard,

             

                dilute the samples with the appropriate Diluent and repeat the

             

                assay.

             

                                                   10


            ----------------------- Page 11-----------------------

            ?  Any      variation    in  operator,    pipetting    technique,     washing

             

                technique,   incubation   time   or  temperature,   and   kit   age   can

             

                cause variation in binding.

             

            ?  This   assay   is   designed   to   eliminate   interference   by   soluble

             

                receptors,     binding    proteins,  and     other   factors   present    in

             

                biological samples. Until all factors have been tested in the

             

                Immunoassay,         the   possibility   of   interference    cannot     be

             

                excluded.

             

            TECHNICAL HINTS

             

            ?  Centrifuge vials before opening to collect contents.

             

            ?  When mixing or reconstituting protein solutions, always avoid

             

                foaming.

             

            ?  To   avoid   cross-contamination,   change   pipette  tips   between

             

                additions of each standard level, between sample additions,

             

                and between reagent additions. Also, use separate reservoirs

             

                for each reagent.

             

            ?  When using an automated plate washer, adding a 30 second

             

                soak     period   following   the   addition   of  wash    buffer,  and/or

             

                rotating    the  plate   180   degrees   between      wash    steps    may

             

                improve assay precision.

             

                                                   11


            ----------------------- Page 12-----------------------

            ?  To ensure accurate results, proper adhesion of plate sealers

             

                during incubation steps is necessary.

             

            ?  Substrate Solution should remain colorless or light blue until

             

                added to the plate. Keep Substrate Solution protected from

             

                light. Substrate Solution should change from colorless or light

             

                blue to gradations of blue.

             

            ?  Stop Solution should be added to the plate in the same order

             

                as the Substrate Solution. The color developed in the wells

             

                will turn from blue to yellow upon addition of the Stop Solution.

             

                Wells that are green in color indicate that the Stop Solution

             

                has not mixed thoroughly with the Substrate Solution.

             

                                                  12

             

            廈門慧嘉生物經(jīng)營ELISA試劑盒及抗體、細胞因子、生化試劑、耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價格實惠,服務(wù)周到,質(zhì)量有保證。:   : http://www.biohj.com/download.aspx(說明書下載) 該說明書是PDF格式轉(zhuǎn)化的,固排版有所變化, 歡迎老師或或索取原版說明書

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =

            請輸驗證碼

            收藏該商鋪

            X
            該信息已收藏!
            標簽:
            保存成功

            (空格分隔,最多3個,單個標簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復(fù)您~
            撥打電話
            在線留言