            人神經(jīng)特異性烯醇化酶(NSE)ELISA Kit 人神經(jīng)特異性烯醇化酶ELISA試劑盒

            時間:2012/8/6閱讀:619
            分享:

            1
            人神經(jīng)特異性烯醇化酶(NSE)ELISA Kit Human Neuron-Specific Enolase
            (NSE)ELISA Kit
            (96T)
            ? This immunoassay kit allows for the in vitro quantitative determination of human NSE
            concentrations in serum, plasma.
            ? Expiration date six months from the date of manufacture
            ? FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
            2
            INTRODUCTION
            Neuron Specific Enolase (NSE) is the most abundant form of the
            glycolytic enolase found in adult neurons and is thought to serve as
            a growth factor in neurons. Of the three enolase subunits (α, β, and
            γ), NSE is a dimer composed of two γ subunits.
            NSE is useful in studying neuronal differentiation and is, therefore,
            a valuable tool for visualizing the entire neuron and endocrine
            systems. Serum levels of NSE have been associated with such
            disease states as Alzheimer's, Huntington's Chorea,
            neuroblastoma, head trauma, neuroendocrine malignancies, and
            small cell carcinomas of the lung.
            PRINCIPLE OF THE ASSAY
            The microtiter plate provided in this kit has been pre-coated with an
            antibody specific to NSE. Standards or samples are then added to
            the appropriate microtiter plate wells with a HRP-conjugated
            antibody preparation specific for NSE to each microplate well and
            incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate
            solution is added to each well. Only those wells that contain NSE,
            HRP-conjugated antibody will exhibit a change in color. The
            3
            enzyme-substrate reaction is terminated by the addition of a
            sulphuric acid solution and the color change is measured
            spectrophotometrically at a wavelength of 450 nm ± 2 nm. The
            concentration of NSE in the samples is then determined by
            comparing the O.D. of the samples to the standard curve.
            DETECTION RANGE
            1.56 ng/ml-100 ng/ml. The standard curve concentrations used for
            the ELISA’s were 100 ng/ml, 50 ng/ml, 25 ng/ml, 12.5 ng/ml, 6.25
            ng/ml, 3.12 ng/ml, 1.56 ng/ml.
            SPECIFICITY
            This assay recognizes human NSE. No significant cross-reactivity
            or interference was observed.
            SENSITIVITY
            The minimum detectable dose of human NSE is typically less than
            0.39 ng/ml.
            The sensitivity of this assay, or Lower Limit of Detection (LLD) was
            defined as the lowest protein concentration that could be
            differentiated from zero.
            4
            MATERIALS PROVIDED
            Reagent Quantity
            Assay plate 1
            Standard 2
            Sample Diluent 2 x 20 ml
            HRP-conjugate Diluent 1 x 10 ml
            HRP-conjugate 1 x 120μl
            Wash Buffer
            1 x 20 ml
            (25×concentrate)
            TMB Substrate 1 x 10 ml
            Stop Solution 1 x 10 ml
            STORAGE
            1. Unopened test kits should be stored at 2-8?C upon receipt and
            the microtiter plate should be kept in a sealed bag. The test kit
            may be used throughout the expiration date of the kit. Refer to
            the package label for the expiration date.
            2. Opened test kits will remain stable until the expiring date shown,
            provided it is stored as prescribed above.
            3. A microtiter plate reader with a bandwidth of 10 nm or less and
            an optical density range of 0-3 OD or greater at 450nm
            wavelength is acceptable for use in absorbance measurement.
            5
            REAGENT PREPARATION
            Bring all reagents to room temperature before use.
            1. Wash Buffer If crystals have formed in the concentrate, warm
            up to room temperature and mix gently until the crystals have
            compley dissolved. Dilute 20 ml of Wash Buffer Concentrate
            into deionized or distilled water to prepare 500 ml of Wash
            Buffer.
            2. Standard Reconstitute the Standard with 1.0 ml of Sample
            Diluent. This reconstitution produces a stock solution of 100
            ng/ml. Allow the standard to sit for a minimum of 15 minutes with
            gentle agitation prior to making serial dilutions. The undiluted
            standard serves as the high standard (100 ng/ml). The Sample
            Diluent serves as the zero standard (0 ng/ml).
            3. HRP-conjugate Dilute to the working concentration using
            HRP-conjugate Diluent(1:100), respectively.
            Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye,
            hand, face, and clothing protection when using this material.
            OTHER SUPPLIES REQUIRED
            ? Microplate reader capable of measuring absorbance at 450 nm,
            with the correction wavelength set at 540 nm or 570 nm.
            6
            ? Pipettes and pipette tips.
            ? Deionized or distilled water.
            ? Squirt bottle, manifold dispenser, or automated microplate
            washer.
            SAMPLE COLLECTION AND STORAGE
            ? Serum Use a serum separator tube (SST) and allow samples
            to clot for 30 minutes before centrifugation for 15 minutes at
            1000 g. Remove serum and assay immediay or aliquot and
            store samples at -20° C. Avoid repeated freeze-thaw cycles.
            ? Plasma Collect plasma using citrate, EDTA, or heparin as an
            anticoagulant. Centrifuge for 15 minutes at 1000 g within 30
            minutes of collection. Assay immediay or aliquot and store
            samples at -20°C. Avoid repeated freeze-thaw cycles.
            Note: Grossly hemolyzed samples are not suitable for use in this assay.
            ASSAY PROCEDURE
            Bring all reagents and samples to room temperature before use. It is recommended
            that all samples, standards, and controls be assayed in duplicate.
            1. Set a Blank well without any solution. Add 100μl of Standard or
            Sample per well. Cover with the adhesive strip. Incubate for
            30min at 37°C.
            7
            2. Aspirate each well and wash, repeating the process three times
            for a total of three washes. Wash by filling each well with Wash
            Buffer (200μl) using a squirt bottle, multi-channel pipette,
            manifold dispenser or autowasher. Complete removal of liquid
            at each step is essential to good performance. After the last
            wash, remove any remaining Wash Buffer by aspirating or
            decanting. Invert the plate and blot it against clean paper towels.
            3. Add 100μl of HRP-conjugate working solution to each well.
            Incubate for 30min at 37°C. HRP-conjugate working solution
            may appear cloudy. Warm up to room temperature and mix
            gently until solution appears uniform.
            4. Repeat the aspiration and wash five times as before.
            5. Add 90μl of TMB Substrate to each well. Incubate for 20
            minutes at 37°C. Keeping the plate away from drafts and other
            temperature fluctuations in the dark.
            6. Add 50μl of Stop Solution to each well. If color change does
            not appear uniform, gently tap the plate to ensure thorough
            mixing.
            7. Determine the optical density of each well within 30 minutes,
            using a microplate reader set to 450 nm.
            8
            CALCULATION OF RESULTS
            Using the professional soft "Curve Exert 1.3" to make a standard curve is
            recommended, which can be downloaded from our web.
            Average the duplicate readings for each standard, control, and
            sample and subtract the average zero standard optical density.
            Create a standard curve by reducing the data using computer
            software capable of generating a four parameter logistic (4-PL)
            curve-fit. As an alternative, construct a standard curve by plotting
            the mean absorbance for each standard on the x-axis against the
            concentration on the y-axis and draw a best fit curve through the
            points on the graph. The data may be linearized by plotting the log
            of the NSE concentrations versus the log of the O.D. and the best fit
            line can be determined by regression analysis. This procedure will
            produce an adequate but less precise fit of the data. If samples
            have been diluted, the concentration read from the standard curve
            must be multiplied by the dilution factor.
            LIMITATIONS OF THE PROCEDURE
            ? The kit should not be used beyond the expiration date on the kit
            label.
            ? Do not mix or substitute reagents with those from other lots or
            sources.
            9
            ? It is important that the Calibrator Diluent selected for the
            standard curve be consistent with the samples being assayed.
            ? If samples generate values higher than the highest standard,
            dilute the samples with the appropriate Calibrator Diluent and
            repeat the assay.
            ? Any variation in Standard Diluent, operator, pipetting technique,
            washing technique, incubation time or temperature, and kit age
            can cause variation in binding.
            ? This assay is designed to eliminate interference by soluble
            receptors, binding proteins, and other factors present in
            biological samples. Until all factors have been tested in the
            Immunoassay, the possibility of interference cannot be
            excluded.
            TECHNICAL HINTS
            ? When mixing or reconstituting protein solutions, always avoid
            foaming.
            ? To avoid cross-contamination, change pipette tips between
            additions of each standard level, between sample additions, and
            between reagent additions. Also, use separate reservoirs for
            each reagent.
            10
            ? When using an automated plate washer, adding a 30 second
            soak period following the addition of wash buffer, and/or rotating
            the plate 180 degrees between wash steps may improve assay
            precision.
            ? To ensure accurate results, proper adhesion of plate sealers
            during incubation steps is necessary.
            ? Substrate Solution should remain colorless until added to the
            plate. Keep Substrate Solution protected from light. Substrate
            Solution should change from colorless to gradations of blue.
            ? Stop Solution should be added to the plate in the same order as
            the Substrate Solution. The color developed in the wells will turn
            from blue to yellow upon addition of the Stop Solution. Wells that
            are green in color indicate that the Stop Solution has not mixed
            thoroughly with the Substrate Solution.

            廈門慧嘉生物長期專業(yè)銷售ELISA試劑盒 ASSAY\ Immunoway\ Santa \ Abcam \ Cst \ jackson \ Pierce \ Sigma \ Amresco \Qiagen \ Cayman \ abnova \ millipore \ invitrogen \ merk \ ebioscience \prospec \ peprotech細(xì)胞因子*。等生物試劑產(chǎn)品。實驗為大,誠信經(jīng)營,為客戶提供“zui高質(zhì)量的產(chǎn)品”和“zui的服務(wù):  : 或登陸http://www.biohj.com(向客服人員索取原版說明書)。歡迎廣大老師來詢!