            人8異前列腺素F2α(8-iso-PGF2a)ELISA kit 人8異前列腺素F2α ELISA試劑盒

            時間:2012/8/6閱讀:648
            分享:

            1
            人8異前列腺素F2α(8-iso-PGF2a)ELISA kit 人8異前列腺素F2α ELISA試劑盒 Human 8-iso prostaglandin F2α
            (8-iso-PGF2α) ELISA Kit
            (96 T)
            l This immunoassay kit allows for the in vitro quantitative determination of human
            8-iso-PGF2α concentrations in serum, plasma and other biological fluids.
            l Expiration date six months from the date of manufacture
            l FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
            2
            INTRODUCTION
            Isoprostanes are a newly-described group of prostaglandin-like
            compounds which can be produced independently of the
            cyclooxygenase pathway. Isoprostanes are formed under
            conditions of oxidant stress through a free radical action on
            arachidonic acid in cell membranes and are subsequently
            cleaved, presumably by the action of phospholipase enzymes.
            Free and estered F2 isoprostanes are amongst the more
            abundant forms with in vivo levels ranging between 5 and 166
            pg/ml in normal human plasma. In addition, in man plasma F2
            isoprostane levels increase with age and are elevated in
            smokers, possibly due to oxidants found incigarette smoke.
            Further, 8-iso PGF2a specically, is increased approximay
            three fold in individuals with non-insulin dependent diabetes
            mellitus, a disease state associated with endothelial dysfunction
            and oxidative damage.
            The biological signicance of isoprostane formation is not
            compley understood. Nevertheless, evidence increasingly
            suggests that isoprostanes have important contractile effects on
            3
            smooth muscle function. Indeed, 8-iso PGF2a has been shown
            to cause contraction of a variety of smooth muscle preparations
            including human myometrium, guinea-pig and human airways,
            rat renal and pulmonary vessels and rabbit pulmonary vessels.
            Where tested, the contractile actions of 8-iso PGF2a are blocked
            by thromboxane receptor (TP) antagonists. 8-Iso PGF2a also
            causes plaet aggregation, possibly via TP receptor activation,
            although evidence suggests that specic isoprostane receptors
            may be present in some preparations. In contrast to the
            contractile actions of 8-iso PGF2a, the putative dilator properties
            of 8-iso PGF2a have not been investigated.
            PRINCIPLE OF THE ASSAY
            The microtiter plate provided in this kit has been pre-coated with
            an antibody specific to 8-iso-PGF2α. Standards or samples are
            then added to the appropriate microtiter plate wells with a
            biotin-conjugated antibody preparation specific for 8-iso-PGF2α
            and Avidin conjugated to Horseradish Peroxidase (HRP) is
            added to each microplate well and incubated. Then a TMB
            4
            (3,3',5,5' tetramethyl-benzidine) substrate solution is added to
            each well. Only those wells that contain 8-iso-PGF2α,
            biotin-conjugated antibody and enzyme-conjugated Avidin will
            exhibit a change in color. The enzyme-substrate reaction is
            terminated by the addition of a sulphuric acid solution and the
            color change is measured spectrophotometrically at a
            wavelength of 450 nm ± 2 nm. The concentration of 8-iso-PGF2α
            in the samples is then determined by comparing the O.D. of the
            samples to the standard curve.
            DETECTION RANGE
            78 pg/ml-5000 pg/ml. The standard curve concentrations used
            for the ELISA’s were 5000 pg/ml, 2500 pg/ml, 1250 pg/ml, 625
            pg/ml, 312 pg/ml, 156 pg/ml, 78 pg/ml.
            SPECIFICITY
            This assay recognizes recombinant and natural human
            8-iso-PGF2α. No significant cross-reactivity or interference was
            observed.
            5
            SENSITIVITY
            The minimum detectable dose of human 8-iso-PGF2α is typically
            less than 20 pg/ml.
            The sensitivity of this assay, or Lower Limit of Detection (LLD)
            was defined as the lowest protein concentration that could be
            differentiated from zero.
            MATERIALS PROVIDED
            Reagent Quantity
            Assay plate 1
            Standard 2
            Sample Diluent 1 x 20 ml
            Biotin-antibody Diluent 1 x 10 ml
            HRP-avidin Diluent 1 x 10 ml
            Biotin-antibody 1 x 120μl
            HRP-avidin 1 x 120μl
            Wash Buffer
            1 x 20 ml
            (25×concentrate)
            TMB Substrate 1 x 10 ml
            Stop Solution 1 x 10 ml
            6
            STORAGE
            1. Unopened test kits should be stored at 2-8°C upon receipt
            and the microtiter plate should be kept in a sealed bag. The
            test kit may be used throughout the expiration date of the kit,
            provided it is stored as prescribed above. Refer to the
            package label for the expiration date.
            2. Opened test plate should be stored at 2-8°C in the aluminum
            foil bag with desiccants to minimize exposure to damp air. The
            kits will remain stable until the expiring date shown, provided it
            is stored as prescribed above.
            3. A microtiter plate reader with a bandwidth of 10 nm or less
            and an optical density range of 0-3 OD or greater at 450nm
            wavelength is acceptable for use in absorbance
            measurement.
            REAGENT PREPARATION
            Bring all reagents to room temperature before use.
            1. Wash Buffer If crystals have formed in the concentrate,
            warm up to room temperature and mix gently until the
            crystals have compley dissolved. Dilute 20 ml of Wash
            Buffer Concentrate into deionized or distilled water to prepare
            500 ml of Wash Buffer.
            7
            2. Standard Centrifuge the standard vial at 6000-10000rpm
            for 30s. Reconstitute the Standard with 1.0 ml of Sample
            Diluent. This reconstitution produces a stock solution of 5000
            pg/ml. Allow the standard to sit for a minimum of 15 minutes
            with gentle agitation prior to making serial dilutions. The
            undiluted standard serves as the high standard (5000 pg/ml).
            The Sample Diluent serves as the zero standard (0 pg/ml).
            Prepare fresh for each assay. Use within 4 hours and discard
            after use.
            3. Biotin-antibody Centrifuge the vial before opening. Dilute
            to the working concentration using Biotin-antibody
            Diluent(1:100), respectively.
            4. HRP-avidin Centrifuge the vial before opening. Dilute to the
            working concentration using HRP-avidin Diluent(1:100),
            respectively.
            Precaution: The Stop Solution provided with this kit is an acid solution. Wear
            eye, hand, face, and clothing protection when using this material.
            OTHER SUPPLIES REQUIRED
            ? Microplate reader capable of measuring absorbance at 450
            nm, with the correction wavelength set at 540 nm or 570 nm.
            8
            ? Pipettes and pipette tips.
            ? Deionized or distilled water.
            ? Squirt bottle, manifold dispenser, or automated microplate
            washer.
            ? An incubator which can provide stable incubation conditions
            up to 37°C±0.5°C.
            SAMPLE COLLECTION AND STORAGE
            l Serum Use a serum separator tube (SST) and allow
            samples to clot for 30 minutes before centrifugation for 15
            minutes at 1000 g. Remove serum and assay immediay or
            aliquot and store samples at -20°C. Centrifuge the sample
            again after thawing before the assay. Avoid repeated
            freeze-thaw cycles.
            l Plasma Collect plasma using citrate, EDTA, or heparin as
            an anticoagulant. Centrifuge for 15 minutes at 1000 g within
            30 minutes of collection. Assay immediay or aliquot and
            store samples at -20°C. Centrifuge the sample again after
            thawing before the assay. Avoid repeated freeze-thaw cycles.
            Note: Grossly hemolyzed samples are not suitable for use in this assay.
            9
            ASSAY PROCEDURE
            Bring all reagents and samples to room temperature before use. It is
            recommended that all samples, standards, and controls be assayed in duplicate.
            All the reagents should be added directly to the liquid level in the well. The
            pipette should avoid contacting the inner wall of the well.
            1. Add 100μl of Standard, Blank, or Sample per well. Cover with
            the adhesive strip. Incubate for 2 hours at 37°C.
            2. Remove the liquid of each well, don’t wash.
            3. Add 100μl of Biotin-antibody working solution to each well.
            Incubate for 1 hour at 37°C. Biotin-antibody working
            solution may appear cloudy. Warm up to room temperature
            and mix gently until solution appears uniform.
            4. Aspirate each well and wash, repeating the process three
            times for a total of three washes. Wash: Fill each well with
            Wash Buffer (200μl) and let it stand for 2 minutes, then
            remove the liquid by flicking the plate over a sink. The
            remaining drops are removed by patting the plate on a paper
            towel. Complete removal of liquid at each step is essential to
            good performance.
            1 0
            5. Add 100μl of HRP-avidin working solution to each well.
            Cover the microtiter plate with a new adhesive strip. Incubate
            for 1 hour at 37°C.
            6. Repeat the aspiration and wash five times as step 4.
            7. Add 90μl of TMB Substrate to each well. Incubate for 10-30
            minutes at 37°C. Keeping the plate away from drafts and
            other temperature fluctuations in the dark.
            8. Add 50μl of Stop Solution to each well when the first four
            wells containing the highest concentration of standards
            develop obvious blue color. If color change does not appear
            uniform, gently tap the plate to ensure thorough mixing.
            9. Determine the optical density of each well within 30 minutes,
            using a microplate reader set to 450 nm.
            CALCULATION OF RESULTS
            Using the professional soft "Curve Exert 1.3" to make a standard curve is
            recommended, which can be downloaded from our web.
            Average the duplicate readings for each standard, control, and
            sample and subtract the average zero standard optical density.
            Create a standard curve by reducing the data using computer
            software capable of generating a four parameter logistic (4-PL)
            1 1
            curve-fit. As an alternative, construct a standard curve by plotting
            the mean absorbance for each standard on the y-axis against
            the concentration on the x-axis and draw a best fit curve through
            the points on the graph. The data may be linearized by plotting
            the log of the 8-iso-PGF2α concentrations versus the log of the
            O.D. and the best fit line can be determined by regression
            analysis. This procedure will produce an adequate but less
            precise fit of the data. If samples have been diluted, the
            concentration read from the standard curve must be multiplied by
            the dilution factor.
            LIMITATIONS OF THE PROCEDURE
            ? The kit should not be used beyond the expiration date on the
            kit label.
            ? Do not mix or substitute reagents with those from other lots or
            sources.
            ? It is important that the Standard Diluent selected for the
            standard curve be consistent with the samples being
            assayed.
            ? If samples generate values higher than the highest standard,
            dilute the samples with the appropriate Standard Diluent and
            repeat the assay.
            1 2
            ? Any variation in Standard Diluent, operator, pipetting
            technique, washing technique, incubation time or
            temperature, and kit age can cause variation in binding.
            ? This assay is designed to eliminate interference by soluble
            receptors, binding proteins, and other factors present in
            biological samples. Until all factors have been tested in the
            Immunoassay, the possibility of interference cannot be
            excluded.
            TECHNICAL HINTS
            ? Centrifuge vials before opening to collect contents.
            ? When mixing or reconstituting protein solutions, always avoid
            foaming.
            ? To avoid cross-contamination, change pipette tips between
            additions of each standard level, between sample additions,
            and between reagent additions. Also, use separate reservoirs
            for each reagent.
            ? When using an automated plate washer, adding a 30 second
            soak period following the addition of wash buffer, and/or
            rotating the plate 180 degrees between wash steps may
            improve assay precision.
            1 3
            ? To ensure accurate results, proper adhesion of plate sealers
            during incubation steps is necessary.
            ? Substrate Solution should remain colorless or light blue until
            added to the plate. Keep Substrate Solution protected from
            light. Substrate Solution should change from colorless or light
            blue to gradations of blue.
            ? Stop Solution should be added to the plate in the same order
            as the Substrate Solution. The color developed in the wells
            will turn from blue to yellow upon addition of the Stop Solution.
            Wells that are green in color indicate that the Stop Solution
            has not mixed thoroughly with the Substrate Solution.

            廈門慧嘉生物長期專業(yè)銷售ELISA試劑盒 ASSAY\ Immunoway\ Santa \ Abcam \ Cst \ jackson \ Pierce \ Sigma \ Amresco \Qiagen \ Cayman \ abnova \ millipore \ invitrogen \ merk \ ebioscience \prospec \ peprotech細胞因子*。等生物試劑產品。實驗為大,誠信經營,為客戶提供“zui高質量的產品”和“zui的服務:  : 或登陸http://www.biohj.com(向客服人員索取原版說明書)。歡迎廣大老師來詢!

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =

            請輸驗證碼

            收藏該商鋪

            X
            該信息已收藏!
            標簽:
            保存成功

            (空格分隔,最多3個,單個標簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復您~
            撥打電話
            在線留言