狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            廈門慧嘉生物科技有限公司
            初級會員 | 第10年

            18906011628

            豬免疫球蛋白E(IgE)ELISA Kit 豬免疫球蛋白E ELISA Kit

            時間:2012/8/11閱讀:130
            分享:

            1
            Porcine Immunoglobulin E
            (IgE)ELISA Kit
            (96T)
            ? This immunoassay kit allows for the in vitro quantitative determination of porcine
            IgE concentrations in serum and plasma,.
            ? Expiration date six months from the date of manufacture
            ? FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
            2
            PRINCIPLE OF THE ASSAY
            The microtiter plate provided in this kit has been pre-coated with
            porcine IgE. Standards or samples are then added to the
            appropriate microtiter plate wells with Horseradish Peroxidase
            (HRP) -conjugated antibody preparation specific for porcine IgE,
            mix well and incubated. The more the amount of porcine IgE in
            samples, the less HRP-conjugated antibody preparation specific
            for porcine IgE bound by pre-coated porcine IgE. Then a TMB
            (3,3',5,5' tetramethyl-benzidine) substrate solution is added to
            each well. And the color develops in opposite to the amount of
            porcine IgE in the sample. The color development is stopped and
            the intensity of the color is measured.
            DETECTION RANGE
            0.05ng/ml-12.5 ng/ml. The standard curve concentrations used
            for the ELISA’s were 12.5 ng/ml, 3.12 ng/ml, 0.78ng/ml,
            0.19ng/ml, 0.05ng/ml.
            SPECIFICITY
            This assay recognizes porcine IgE. No significant cross-reactivity
            or interference was observed.
            3
            SENSITIVITY
            The minimum detectable dose of porcine IgE is typically less
            than 0.05ng/ml.
            The sensitivity of this assay, or Lower Limit of Detection (LLD)
            was defined as the lowest protein concentration that could be
            differentiated from zero.
            MATERIALS PROVIDED
            Reagent Quantity
            Assay plate 1
            Standard 6 x 0.5 ml
            Sample Diluent 2 x 20 ml
            HRP- conjugate 1 x 6 ml
            Wash Buffer
            1 x 20 ml
            (25×concentrate)
            TMB Substrate 1 x 10 ml
            Stop Solution 1 x 10 ml
            Standard S1 S 2 S3 S4 S5 S6
            Concentration
            (ng/ml) 0 0.05 0.19 0.78 3.12 12.5
            4
            STORAGE
            1. Unopened test kits should be stored at 2-8?C upon receipt
            and the microtiter plate should be kept in a sealed bag. The
            test kit may be used throughout the expiration date of the kit,
            provided it is stored as prescribed above. Refer to the
            package label for the expiration date.
            2. Opened test plate should be stored at 2-8?C in the aluminum
            foil bag with desiccants to minimize exposure to damp air. The
            kits will remain stable until the expiring date shown, provided it
            is stored as prescribed above.
            3. A microtiter plate reader with a bandwidth of 10 nm or less
            and an optical density range of 0-3 OD or greater at 450nm
            wavelength is acceptable for use in absorbance
            measurement.
            REAGENT PREPARATION
            Bring all reagents to room temperature before use.
            1. Wash Buffer If crystals have formed in the concentrate,
            warm up to room temperature and mix gently until the
            crystals have compley dissolved. Dilute 20 ml of Wash
            Buffer Concentrate into deionized or distilled water to prepare
            500 ml of Wash Buffer.
            5
            OTHER SUPPLIES REQUIRED
            ? Microplate reader capable of measuring absorbance at 450
            nm, with the correction wavelength set at 540 nm or 570 nm.
            ? Pipettes and pipette tips.
            ? Deionized or distilled water.
            ? Squirt bottle, manifold dispenser, or automated microplate
            washer.
            ? An incubator which can provide stable incubation conditions
            up to 37°C±0.5°C.
            SAMPLE COLLECTION AND STORAGE
            ? Serum Use a serum separator tube (SST) and allow
            samples to clot for 30 minutes before centrifugation for 15
            minutes at 1000 g. Remove serum and assay immediay or
            aliquot and store samples at -20°C. Centrifuge the sample
            again after thawing before the assay. Avoid repeated
            freeze-thaw cycles.
            ? Plasma Collect plasma using citrate, EDTA, or heparin as
            an anticoagulant. Centrifuge for 15 minutes at 1000 g within
            30 minutes of collection. Assay immediay or aliquot and
            6
            store samples at -20°C. Centrifuge the sample again after
            thawing before the assay. Avoid repeated freeze-thaw cycles.
            Note: Grossly hemolyzed samples are not suitable for use in this assay.
            ASSAY PROCEDURE
            Bring all reagents and samples to room temperature before use. It is
            recommended that all samples, standards, and controls be assayed in duplicate.
            All the reagents should be added directly to the liquid level in the well. The
            pipette should avoid contacting the inner wall of the well.
            1. Recommend to dilute the serum and plasma samples with
            Sample Diluent(1:1000) before test. The suggested 1000-fold
            dilution can be achieved by adding 5μl sample to 95μl of
            Sample Diluent. Complete the 1000-fold dilution by adding
            5μl of this solution to 245μl of Sample Diluent. The
            recommended dilution factor is for reference only. The
            optimal dilution factor should be determined by users
            according to their particular experiments.
            2. Add 50μl of Standard or Sample per well. Add 50μl of HRPconjugate
            to each well immediay. Mix well with the pipette
            or shake the plate gently for 60 seconds.
            3. Then incubate for 40 minutes at 37° C.
            4. Aspirate each well and wash, repeating the process five
            times for a total of five washes. Wash: Fill each well with
            7
            Wash Buffer (200μl) and let it stand for 2 minutes, then
            remove the liquid by flicking the plate over a sink. The
            remaining drops are removed by patting the plate on a paper
            towel. Complete removal of liquid at each step is essential to
            good performance.
            5. Add 90μl of TMB Substrate to each well. Incubate for 20
            minutes at 37°C. Keeping the plate away from drafts and
            other temperature fluctuations in the dark.
            6. Add 50μl of Stop Solution to each well when the last four
            wells containing the lowest concentration of standards
            develop obvious blue color. If color change does not appear
            uniform, gently tap the plate to ensure thorough mixing.
            7. Determine the optical density of each well within 15 minutes,
            using a microplate reader set to 450 nm.
            CALCULATION OF RESULTS
            Using the professional soft "Curve Exert 1.3" to make a standard curve is
            recommended, which can be downloaded from our web.
            Average the duplicate readings for each standard, control, and
            sample and divide the average zero standard optical density.
            Create a standard curve by reducing the data using computer
            8
            software. As an alternative, construct a standard curve by
            plotting the absorbance ratio for each standard on the x-axis
            against the concentration on the y-axis and draw a best fit curve
            through the points on the graph. The data may be linearized by
            plotting the porcine IgE concentrations versus the ratio and the
            best fit line can be determined by regression analysis. This
            procedure will produce an adequate but less precise fit of the
            data. If samples have been diluted, the concentration read from
            the standard curve must be multiplied by the dilution factor.
            LIMITATIONS OF THE PROCEDURE
            ? The kit should not be used beyond the expiration date on the
            kit label.
            ? Do not mix or substitute reagents with those from other lots or
            sources.
            ? If samples generate values higher than the highest standard,
            dilute the samples with the appropriate Diluent and repeat the
            assay.
            ? Any variation in operator, pipetting technique, washing
            technique, incubation time or temperature, and kit age can
            cause variation in binding.
            9
            ? This assay is designed to eliminate interference by soluble
            receptors, binding proteins, and other factors present in
            biological samples. Until all factors have been tested in the
            Immunoassay, the possibility of interference cannot be
            excluded.
            TECHNICAL HINTS
            ? Centrifuge vials before opening to collect contents.
            ? When mixing or reconstituting protein solutions, always avoid
            foaming.
            ? To avoid cross-contamination, change pipette tips between
            additions of each standard level, between sample additions,
            and between reagent additions. Also, use separate reservoirs
            for each reagent.
            ? When using an automated plate washer, adding a 30 second
            soak period following the addition of wash buffer, and/or
            rotating the plate 180 degrees between wash steps may
            improve assay precision.
            ? To ensure accurate results, proper adhesion of plate sealers
            during incubation steps is necessary.
            10
            ? Substrate Solution should remain colorless or light blue until
            added to the plate. Keep Substrate Solution protected from
            light. Substrate Solution should change from colorless or light
            blue to gradations of blue.
            ? Stop Solution should be added to the plate in the same order
            as the Substrate Solution. The color developed in the wells
            will turn from blue to yellow upon addition of the Stop Solution.
            Wells that are green in color indicate that the Stop Solution
            has not mixed thoroughly with the Substrate Solution.

             

             

            廈門慧嘉生物長期專業(yè)銷售ELISA試劑盒\(zhòng)AssayBiotech\Santa \BD\Immunoway\ Abcam \ Cst \ jackson \ Pierce \ Sigma \ Amresco \Qiagen \ Cayman \ abnova \ millipore \ invitrogen \ merk \ ebioscience \prospec \ peprotech細胞因子*。等生物試劑產品。實驗為大,誠信經營,為客戶提供zui高質量的產品zui的服務
                
            :
            登陸http://www.biohj.com向客服人員索取原版說明書。
            歡迎廣大老師來詢!

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =請輸驗證碼

            收藏該商鋪

            X
            該信息已收藏!
            標簽:
            保存成功

            (空格分隔,最多3個,單個標簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復您~
            撥打電話
            在線留言