            小鼠前列腺素E2(PGE2)ELISA Kit 小鼠前列腺素E2 ELISA Kit

            時間:2012/8/11閱讀:143
            分享:

            1
            Mouse Prostaglandin E2
            (PG-E2) ELISA Kit
            (96T)
            This immunoassay kit allows for the in vitro quantitative determination of mouse
            PG-E2 concentrations in serum, plasma and other biological fluids.
            Expiration date six months from the date of manufacture
            FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
            2
            PRINCIPLE OF THE ASSAY
            The microtiter plate provided in this kit has been pre-coated with
            an goat-anti-rabbit antibody. Standards or samples are then
            added to the appropriate microtiter plate wells with a
            HRP-conjugated PG-E2 and antibody preparation specific for
            PG-E2 and incubated. Then substrate solutions are added to
            each well. The enzyme-substrate reaction is terminated by the
            addition of a sulphuric acid solution and the color change is
            measured spectrophotometrically at a wavelength of 450 nm ± 2
            nm. The concentration of PG-E2 in the samples is then
            determined by comparing the O.D. of the samples to the
            standard curve.
            DETECTION RANGE
            0.32 pg/ml-80 pg/ml. The standard curve concentrations used for
            the ELISA’s were 80 pg/ml, 20 pg/ml, 5 pg/ml, 1.24 pg/ml, 0.32
            pg/ml。
            SPECIFICITY
            This assay recognizes recombinant and natural mouse PG-E2.
            No significant cross-reactivity or interference was observed.
            3
            SENSITIVITY
            The minimum detectable dose of mouse PG-E2 is typically less
            than 0.2 pg/ml.
            The sensitivity of this assay, or Lower Limit of Detection (LLD)
            was defined as the lowest protein concentration that could be
            differentiated from zero.
            MATERIALS PROVIDED
            Reagent Quantity
            Assay plate 1
            Standards (S1-S5) 5 x 0.5 ml
            HRP-conjugate 1 x 6 ml
            Antibody 1 x 6 ml
            Wash Buffer
            1 x 15 ml
            (20×concentrate)
            Substrate A 1 x 7 ml
            Substrate B 1 x 7 ml
            Stop Solution 1 x 7 ml
            Standard S 1 S 2 S 3 S 4 S 5
            Concentration(pg/ml) 0.32 1.24 5 20 80
            4
            STORAGE
            1. Unopened test kits should be stored at 2-8°C upon receipt
            and the microtiter plate should be kept in a sealed bag. The
            test kit may be used throughout the expiration date of the kit.
            Refer to the package label for the expiration date.
            2. Opened test kits will remain stable until the expiring date
            shown, provided it is stored as prescribed above.
            3. A microtiter plate reader with a bandwidth of 10 nm or less
            and an optical density range of 0-3 OD or greater at 450nm
            wavelength is acceptable for use in absorbance
            measurement.
            TECHNICAL HINTS
            1. Bring all reagents and plate to room temperature for at least
            30 minutes before use. Unused wells need store at 2-8℃and
            avoid sunlight.
            2. Wash Buffer If crystals have formed in the concentrate,
            warm to room temperature and mix gently until the crystals
            have compley dissolved. Dilute 15 ml of Wash Buffer
            Concentrate into deionized or distilled water to prepare 300 ml
            of Wash Buffer.
            5
            3. To avoid cross-contamination, change pipette tips between
            additions of each standard level, between sample additions,
            and between reagent additions. Also, use separate reservoirs
            for each reagent.
            4. When using an automated plate washer, adding a 30 second
            soak period following the addition of wash buffer, and/or
            rotating the plate 180 degrees between wash steps may
            improve assay precision.
            5. To ensure accurate results, proper adhesion of plate sealers
            during incubation steps is necessary. Sealers can not be
            reused.
            6. Substrate Solution should remain colorless until added to the
            plate. Keep Substrate Solution protected from light. Substrate
            Solution should change from colorless to gradations of blue.
            7. Stop Solution should be added to the plate in the same order
            as the Substrate Solution. The color developed in the wells
            will turn from blue to yellow upon addition of the Stop Solution.
            Wells that are green in color indicate that the Stop Solution
            has not mixed thoroughly with the Substrate Solution.
            Precaution: The Stop Solution provided with this kit is an acid solution. Wear
            eye, hand, face, and clothing protection when using this material.
            6
            OTHER SUPPLIES REQUIRED
            Microplate reader capable of measuring absorbance at 450
            nm, with the correction wavelength set at 540 nm or 570 nm.
            Pipettes and pipette tips.
            Deionized or distilled water.
            Squirt bottle, manifold dispenser, or automated microplate
            washer.
            SAMPLE COLLECTION AND STORAGE
            Serum Use a serum separator tube (SST) and allow
            samples to clot for 30 minutes before centrifugation for 15
            minutes at 1000 x g. Remove serum and assay immediay
            or aliquot and store samples at -20° C. Centrifuge the sample
            again after thawing before the assay. Avoid repeated
            freeze-thaw cycles.
            Plasma Collect plasma using citrate, EDTA, or heparin as
            an anticoagulant. Centrifuge for 15 minutes at 1000 g within
            30 minutes of collection. Assay immediay or aliquot and
            store samples at -20°C. Centrifuge the sample again after
            thawing before the assay. Avoid repeated freeze-thaw cycles.
            Note: Grossly hemolyzed samples are not suitable for use in this assay.
            7
            ASSAY PROCEDURE
            Bring all reagents and samples to room temperature before use. It is
            recommended that all samples, standards, and controls be assayed in duplicate.
            All the reagents should be added directly to the liquid level in the well. The
            pipette should avoid contacting the inner wall of the well.
            1. Set a Blank well without any solution. Add 50μl of Standard or
            Sample per well. Standards need test in duplicate.
            2. Add 50μl of HRP-conjugate to each well (not to Blank well),
            then add 50μl Antibody to each well. Mix well and then
            incubate for 1 hour at 37°C.
            3. Fill each well with Wash Buffer (about 200μl), stay for 10
            seconds and Spinning. Repeat the process for a total of three
            washes. Complete removal of liquid at each step is essential
            to good performance. After the last wash, remove any
            remaining Wash Buffer by aspirating or decanting. Invert the
            plate and blot it against clean paper towels.
            4. Add 50μl of Substrate A and Substrate B to each well, mix
            well. Incubate for 15 minutes at 37°C. Keeping the plate away
            from drafts and other temperature fluctuations in the dark.
            8
            5. Add 50μl of Stop Solution to each well. If color change does
            not appear uniform, gently tap the plate to ensure thorough
            mixing.
            6. Determine the optical density of each well within 10 minutes,
            using a microplate reader set to 450 nm.
            CALCULATION OF RESULTS
            Using the professional soft "Curve Exert 1.3" to make a standard curve is
            recommended, which can be downloaded from our web.
            Average the duplicate readings for each standard, Blank, and
            sample and subtract the optical density of Blank. Create a
            standard curve by reducing the data using computer software
            capable of generating a four parameter logistic (4-PL) curve-fit.
            As an alternative, construct a standard curve by plotting the
            mean absorbance for each standard on the y-axis against the
            concentration on the x-axis and draw a best fit curve through the
            points on the graph. The data may be linearized by plotting the
            log of the PG-E2 concentrations versus the log of the O.D. and
            the best fit line can be determined by regression analysis. This
            procedure will produce an adequate but less precise fit of the
            data. If samples have been diluted, the concentration read from
            the standard curve must be multiplied by the dilution factor.
            9
            LIMITATIONS OF THE PROCEDURE
            The kit should not be used beyond the expiration date on the
            kit label.
            Do not mix or substitute reagents with those from other lots or
            sources.
            It is important that the Calibrator Diluent selected for the
            standard curve be consistent with the samples being
            assayed.
            If samples generate values higher than the highest standard,
            dilute the samples with the appropriate Calibrator Diluent and
            repeat the assay.
            Any variation in Standard Diluent, operator, pipetting
            technique, washing technique, incubation time or
            temperature, and kit age can cause variation in binding.
            This assay is designed to eliminate interference by soluble
            receptors, binding proteins, and other factors present in
            biological samples. Until all factors have been tested in the
            Immunoassay, the possibility of interference cannot be
            excluded.
             

             

            廈門慧嘉生物長期專業(yè)銷售ELISA試劑盒\(zhòng)AssayBiotech\Santa \BD\Immunoway\ Abcam \ Cst \ jackson \ Pierce \ Sigma \ Amresco \Qiagen \ Cayman \ abnova \ millipore \ invitrogen \ merk \ ebioscience \prospec \ peprotech細(xì)胞因子*。等生物試劑產(chǎn)品。實驗為大,誠信經(jīng)營,為客戶提供zui高質(zhì)量的產(chǎn)品zui的服務(wù)
                
            :
            登陸http://www.biohj.com向客服人員索取原版說明書
            歡迎廣大老師來詢!

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =

            請輸驗證碼

            收藏該商鋪

            X
            該信息已收藏!
            標(biāo)簽:
            保存成功

            (空格分隔,最多3個,單個標(biāo)簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復(fù)您~
            撥打電話
            在線留言