            Human Insulin (INS)
            ELISA Kit
             
             
            Catalog No. CSB-E05069h
            (96T)
             
             
             
             
              This  immunoassay  kit  allows  for  the  in  vitro  quantitative  determination  of  human  INS
            concentrations in serum, plasma and other biological fluids.
              Expiration date      six months from the date of manufacture
              FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
             
             
             
             
            CUSABIO BIOTECH CO., LTD.
            http://www.cusabio.com/    http://www.cusabio.cn/
            : cusabio@cusabio.com    cusabio@cusabio.cn 
              2
            INTRODUCTION
            Insulin is a peptide hormone composed of 51 amino acid residues and has
            a molecular weight of 5808 Da. It is produced in the islets of Langerhans
            in  the  pancreas.  Insulin's  structure  varies  slightly  between  species  of
            animal.  Insulin  has  extensive  effects  on  both  metabolism  and  several
            other body systems (eg, vascular compliance). Insulin causes most of the
            body's cells  to  take up glucose  from  the blood  (including  liver, muscle,
            and  fat  tissue cells),  storing  it as glycogen  in  the  liver and muscle, and
            stops  use  of  fat  as  an  energy  source. When  insulin  is  absent  (or  low),
            glucose is not taken up by most body cells and the body begins to use fat
            as an energy source (ie, transfer of lipids from adipose tissue to the liver
            for mobilization as an energy source). As  its level  is a central metabolic
            control mechanism, its status is also used as a control signal to other body
            systems  (such as amino acid uptake by body cells).  It has  several other
            anabolic effects throughout the body.
            PRINCIPLE OF THE ASSAY
            The  microtiter  plate  provided  in  this  kit  has  been  pre-coated  with  an
            antibody  specific  to  INS.  Standards  or  samples  are  then  added  to  the
            appropriate  microtiter  plate  wells  with  a  HRP-conjugated  monoclonal
            antibody  preparation  specific  for  INS  and  incubated.  Then  substrate
            solution  is  added  to  each well. Only  those wells  that  contain  INS  and
            HRP-conjugated  antibody  will  exhibit  a  change  in  color.  The
            enzyme-substrate  reaction  is  terminated  by  the  addition  of  a  sulphuric
            acid solution and the color change is measured spectrophotometrically at
            a wavelength of 450 nm ± 2 nm. The concentration of INS in the samples
            is then determined by comparing the O.D. of the samples to the standard
            curve. 
              3
            DETECTION RANGE
            8  µIU/ml-140  µIU/ml.  The  standard  curve  concentrations  used  for  the
            ELISA’s were 140 µIU/ml, 80 µIU/ml, 32 µIU/ml, 16 µIU/ml, 8 µIU/ml.
            SPECIFICITY
            This  assay  recognizes  recombinant  and  natural  human  INS.  No
            significant cross-reactivity or interference was observed.
            MATERIALS PROVIDED
            Reagent      Quantity
            Assay plate  1
            Standards (S1-S5)  5  
            HRP-conjugate  1 x 6 ml
            Wash Buffer      
            1 x 15 ml
              (20×concentrate)
            Substrate A  1 x 7 ml
            Substrate B  1 x 7 ml
            Stop Solution      1 x 7 ml
            STORAGE
            1.  Unopened  test  kits  should  be  stored  at  2-8°C  upon  receipt  and  the
            microtiter  plate  should  be  kept  in  a  sealed  bag  with  desiccants  to
            minimize exposure  to damp air. The  test kit may be used  throughout
            the  expiration  date  of  the  kit.  Refer  to  the  package  label  for  the
            expiration date. 
              4
            2.  Opened  test  kits  will  remain  stable  until  the  expiring  date  shown,
            provided it is stored as prescribed above.    
            3.  A microtiter  plate  reader with  a  bandwidth  of  10 nm  or  less  and  an
            optical  density  range  of  0-3 OD  or  greater  at  450nm wavelength  is
            acceptable for use in absorbance measurement.
            TECHNICAL HINTS
            1.  Bring  all  reagents  and  plate  to  room  temperature  for  at  least  30
            minutes  before  use.  Unused  wells  need  store  at  2-8  ℃and  avoid
            sunlight.
            2.  Wash Buffer    If  crystals  have  formed  in  the  concentrate, warm  to
            room  temperature  and mix  gently  until  the  crystals  have  compley
            dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or
            distilled water to prepare 300 ml of Wash Buffer.
            3.  Standard    Reconstitute  the  Standards  with  0.5  ml  of  ddH2O,
            respectively. Allow  the  standard  to  sit  for a minimum of 15 minutes
            with gentle agitation prior to use.  
            4.  To  avoid  cross-contamination,  change pipette  tips between  additions
            of  each  standard  level,  between  sample  additions,  and  between
            reagent additions. Also, use separate reservoirs for each reagent.
            5.  When  using  an  automated  plate  washer,  adding  a  30  second  soak
            period following the addition of wash buffer, and/or rotating the plate
            180 degrees between wash steps may improve assay precision.
            6.  To  ensure  accurate  results,  proper  adhesion  of  plate  sealers  during
            incubation steps is necessary. Sealers can not be reused.
            7.  Substrate  Solution  should  remain  colorless  until  added  to  the  plate.
            Keep  Substrate  Solution  protected  from  light.  Substrate  Solution
            should change from colorless to gradations of blue.
            8.  Stop Solution  should  be  added  to  the plate  in  the  same  order  as  the 
              5
            Substrate  Solution. The  color  developed  in  the wells will  turn  from
            blue  to  yellow  upon  addition  of  the  Stop  Solution. Wells  that  are
            green  in  color  indicate  that  the  Stop  Solution  has  not  mixed
            thoroughly with the Substrate Solution.
            Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye,
            hand, face, and clothing protection when using this material.
            OTHER SUPPLIES REQUIRED
              Microplate  reader capable of measuring absorbance at 450 nm, with
            the correction wavelength set at 540 nm or 570 nm.
              Pipettes and pipette tips.
              Deionized or distilled water.
              Squirt bottle, manifold dispenser, or automated microplate washer.
            SAMPLE COLLECTION AND STORAGE
              Serum    Use a serum separator tube (SST) and allow samples to clot
            for  30  minutes  before  centrifugation  for  15  minutes  at  1000  x  g.
            Remove serum and assay immediay or aliquot and store samples at
            -20° C. Avoid repeated freeze-thaw cycles.
              Plasma    Collect  plasma  using  citrate,  EDTA,  or  heparin  as  an
            anticoagulant.  Centrifuge  for  15  minutes  at  1000  x  g  within  30
            minutes  of  collection.  Assay  immediay  or  aliquot  and  store
            samples at -20° C. Avoid repeated freeze-thaw cycles.
            Note: Grossly hemolyzed samples are not suitable for use in this assay.
            ASSAY PROCEDURE
            Bring all reagents and samples to room temperature before use. It is recommended 
              6
            that all samples, standards, and controls be assayed in duplicate.
            1.  Set  a  Blank  well  without  any  solution.  Add  50µl  of  Standard  or
            Sample per well. Standard need test in duplicate.  
            2.  Add 50µl of HRP-conjugate  to each well  (not  to Blank well). Mix
            well and then incubate for 2 hour at 37°C.  
            3.  Fill  each well with Wash Buffer  (about 350µl),  stay  for 10  seconds
            and  Spinning.  Repeat  the  process  for  a  total  of  three  washes.
            Complete  removal  of  liquid  at  each  step  is  essential  to  good
            performance. After the last wash, remove any remaining Wash Buffer
            by  aspirating or decanting.  Invert  the plate  and blot  it  against  clean
            paper towels.
            4.  Add 50µl of Substrate A  and Substrate B  to  each well, mix well.
            Incubate for 15 minutes at 37°C. Keeping the plate away from drafts
            and other temperature fluctuations in the dark.
            5.  Add  50µl  of  Stop  Solution  to  each well.  If  color  change  does  not
            appear uniform, gently tap the plate to ensure thorough mixing.
            6.  Determine the optical density of each well within 10 minutes, using a
            microplate reader set to 450 nm.
            CALCULATION OF RESULTS
            Average the duplicate readings for each standard, Blank, and sample and
            subtract the optical density of Blank. Create a standard curve by reducing
            the data using computer software capable of generating a four parameter
            logistic (4-PL) curve-fit. As an alternative, construct a standard curve by
            plotting the mean absorbance for each standard on the y-axis against the
            concentration on  the x-axis and draw a best  fit curve  through  the points
            on  the graph. The data may be  linearized by plotting  the  log of  the  INS
            concentrations  versus  the  log  of  the  O.D.  and  the  best  fit  line  can  be 
              7
            determined  by  regression  analysis.  This  procedure  will  produce  an
            adequate but less precise fit of the data. If samples have been diluted, the
            concentration  read  from  the  standard  curve must  be multiplied  by  the
            dilution factor.
            LIMITATIONS OF THE PROCEDURE
              The kit should not be used beyond the expiration date on the kit label.
              Do  not  mix  or  substitute  reagents  with  those  from  other  lots  or
            sources.
              Any  variation  in  operator,  pipetting  technique,  washing  technique,
            incubation  time  or  temperature,  and  kit  age  can  cause  variation  in
            binding.
              This assay is designed to eliminate interference by soluble receptors,
            binding  proteins,  and  other  factors  present  in  biological  samples.
            Until all factors have been tested in the Quantikine Immunoassay, the
            possibility of interference cannot be excluded.

            慧嘉生物您實(shí)驗(yàn)身邊的好伙伴
            為客戶提供“zui高品質(zhì)的產(chǎn)品”和“zui的服務(wù)”
            AssayBiotech  CUSABIO   Immunoway  Santa   Abcam   Cst   jackson   Pierce  Sigma  Amresco  Qiagen  Cayman  abnova  millipore  invitrogen  merk  ebioscience prospec
             LifeSpan  BD 歡迎廣大客戶咨詢,另有大量宣傳海報(bào)和小禮品贈送。
            www.biohj.com  
            :382603320   1284882975

            :   
             

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =

            請輸驗(yàn)證碼

            收藏該商鋪

            X
            該信息已收藏!
            標(biāo)簽:
            保存成功

            (空格分隔,最多3個,單個標(biāo)簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復(fù)您~
            撥打電話
            在線留言