            時間:2013/4/23閱讀:242
            分享:


            Porcine Interleukin 6 (IL-6)
            ELISA Kit
             
             
             
             
            Catalog No. CSB-E06786p
            (96T)
             
             
             
             
             
             
              This immunoassay kit allows for the in vitro quantitative determination of porcine
            IL-6 concentrations in serum, plasma.
              Expiration date      six months from the date of manufacture
              FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
             
             
             
              2
            INTRODUCTION
            Interleukin-6 (IL-6) is a protein that in humans is encoded by the
            IL6  gene.  IL-6  is  an  interleukin  that  acts  as  both  a
            pro-inflammatory  and  anti-inflammatory  cytokine.  It  is  secreted
            by T  cells  and macrophages  to  stimulate  immune  response  to
            trauma,  especially  burns  or  other  tissue  damage  leading  to
            inflammation.  In  terms of host  response  to a  foreign pathogen,
            IL-6  has  been  shown,  in  mice,  to  be  required  for  resistance
            against the bacterium, Streptococcus pneumoniae. IL-6 is also a
            "myokine," a cytokine produced from muscle, and is elevated in
            response  to muscle  contraction.  It  is significantly elevated with
            exercise, and precedes the appearance of other cytokines in the
            circulation. During exercise, it is thought to act in a hormone-like
            manner  to  mobilize  extracellular  substrates  and/or  augment
            substrate delivery (Petersen, J Appl Physiol 2005). Additionally,
            osteoblasts  secrete  IL-6  to  stimulate  osteoclast  formation.
            Smooth muscle cells in the tunica media of many blood vessels
            also produce  IL-6 as a pro-inflammatory cytokine.  IL-6's role as
            an anti-inflammatory  cytokine  is mediated  through  its  inhibitory
            effects on TNF-alpha and IL-1, and activation of IL-1ra and IL-10. 
              3
            IL-6  is one of  the most  important mediators of  fever and of  the
            acute phase response.  It  is capable of crossing  the blood brain
            barrier  and  initiating  synthesis  of  PGE2  in  the  hypothalamus,
            thereby changing the body's temperature setpoint. In the muscle
            and  fatty  tissue  IL-6 stimulates energy mobilization which  leads
            to  increased  body  temperature.  IL-6  can  be  secreted  by
            macrophages  in  response  to  specific  microbial  molecules,
            referred to as pathogen associated molecular patterns (PAMPs).
            IL-6 is also essential for hybridoma growth and is found in many
            supplemental cloning media such as briclone.  Inhibitors of  IL-6
            (including  estrogen)  are  used  to  treat  postmenopausal
            osteoporosis. Il-6 is also produced by adipocytes and is thought
            to be a reason why obese individuals have higher endogeneous
            levels  of CRP.  In  a  2009  study,  intranasally  administered  IL-6
            was  shown  to  improve  sleep-associated  consolidation  of
            emotional memories.
            PRINCIPLE OF THE ASSAY
            The microtiter plate provided in this kit has been pre-coated with
            an  antibody  specific  to  IL-6.  Standards  or  samples  are  then 
              4
            added to the appropriate microtiter plate wells with a Horseradish
            Peroxidase  (HRP)-conjugated monoclonal antibody preparation
            specific for IL-6 and incubated. Then substrate solution A and B
            are  added  to  each  well.  Only  those  wells  that  contain  IL-6,
            HRP-conjugated  antibody  will  exhibit  a  change  in  color.  The
            enzyme-substrate  reaction  is  terminated  by  the  addition  of  a
            sulphuric  acid  solution  and  the  color  change  is  measured
            spectrophotometrically at a wavelength of 450 nm ± 2 nm. The
            concentration  of  IL-6  in  the  samples  is  then  determined  by
            comparing the O.D. of the samples to the standard curve.
            DETECTION RANGE
            The standard curve concentrations used for the ELISA’s were 80
            pg/ml, 40 pg/ml, 20 pg/ml, 10 pg/ml, 4 pg/ml, 2pg/ml.
            SPECIFICITY
            This assay recognizes recombinant and natural porcine IL-6. No
            significant cross-reactivity or interference was observed. 
              5
            SENSITIVITY
            The minimum  detectable  dose  of  porcine  IL-6  is  typically  less
            than  1  pg/ml.  The  sensitivity  of  this  assay,  or  Lower  Limit  of
            Detection  (LLD)  was  defined  as  the  lowest  concentration  that
            could be differentiated from zero.
            MATERIALS PROVIDED
            Reagent      Quantity
            Assay plate  1
            Standard(S1-S6)  6
            HRP-conjugate  1 x 6 ml
            Wash Buffer      
            1 x 15 ml
              (20×concentrate)
            Substrate A  1 x 6 ml
            Substrate B  1 x 6 ml
            Stop Solution      1x 6 ml
             
            Standard  S1  S2  S3  S4  S5  S6
            Concentration (pg/ml)  2  4  10  20  40  80 
              6
            STORAGE
            1. Unopened  test  kits  should  be  stored  at  2-8°C  upon  receipt
            and  the microtiter plate should be kept  in a sealed bag. The
            test kit may be used throughout the expiration date of the kit,
            provided  it  is  stored  as  prescribed  above.  Refer  to  the
            package label for the expiration date.
            2. Opened test plate should be stored at 2-8°C in the aluminum
            foil bag with desiccants to minimize exposure to damp air. The
            kits will remain stable until the expiring date shown, provided it
            is stored as prescribed above.    
            3.  A microtiter  plate  reader with  a  bandwidth  of  10  nm  or  less
            and an optical density  range of 0-3 OD or greater at 450nm
            wavelength  is  acceptable  for  use  in  absorbance
            measurement.
            REAGENT PREPARATION
            1.  Bring all reagents and plate  to room  temperature  for at  least
            30 minutes before use. Unused wells need store at 2-8°C and
            avoid sunlight. 
              7
            2. Wash  Buffer    If  crystals  have  formed  in  the  concentrate,
            warm  to  room  temperature  and mix  gently  until  the  crystals
            have  compley  dissolved.  Dilute  15  ml  of  Wash  Buffer
            Concentrate into deionized or distilled water to prepare 300 ml
            of Wash Buffer.
            Precaution: The Stop Solution provided with this kit is an acid solution. Wear
            eye, hand, face, and clothing protection when using this material.
            OTHER SUPPLIES REQUIRED
              Microplate  reader capable of measuring absorbance at 450
            nm, with the correction wavelength set at 540 nm or 570 nm.
              Pipettes and pipette tips.
              Deionized or distilled water.
              Squirt bottle, manifold dispenser, or automated microplate
            washer.
              An incubator which can provide stable incubation conditions
            up to 37°C±0.5°C.
            SAMPLE COLLECTION AND STORAGE
              Serum    Use  a  serum  separator  tube  (SST)  and  allow 
              8
            samples  to  clot  for  30 minutes  before  centrifugation  for  15
            minutes at 1000 g. Remove serum and assay immediay or
            aliquot  and  store  samples  at  -20°C. Centrifuge  the  sample
            again  after  thawing  before  the  assay.  Avoid  repeated
            freeze-thaw cycles.
              Plasma    Collect plasma using citrate, EDTA, or heparin as
            an anticoagulant. Centrifuge for 15 minutes at 1000 g within
            30 minutes  of  collection.  Assay  immediay  or  aliquot  and
            store  samples  at  -20°C.  Centrifuge  the  sample  again   after
            thawing before the assay. Avoid repeated freeze-thaw cycles.
            Note: Grossly hemolyzed samples are not suitable for use in this assay.
            ASSAY PROCEDURE
            Bring  all  reagents  and  samples  to  room  temperature  before  use.  It  is
            recommended that all samples, standards, and controls be assayed in duplicate.
            All  the  reagents  should  be  added  directly  to  the  liquid  level  in  the well.  The
            pipette should avoid contacting the inner wall of the well.
            1.  Set a Blank well without any solution. Add 100µl of Standard
            or Sample per well. Standard need test in duplicate.  
            2.  Add 50µl of HRP-conjugate to each well (not to Blank well).
            Mix well and then incubate for 2 hours at 37°C.   
              9
            3.  Complete  remove  the  liquid.  Then  fill  each well with Wash
            Buffer  (about  200µl),  stay  for  10  seconds  and  Spinning.
            Repeat  the  process  for  a  total  of  three  washes.  Complete
            removal  of  liquid  at  each  step  is  essential  to  good
            performance.  After  the  last  wash,  remove  any  remaining
            Wash Buffer by aspirating or decanting.  Invert  the plate and
            blot it against clean paper towels.
            4.  Add 50µl of Substrate A and 50µl of Substrate B  to each
            well, mix well.  Incubate for 15 minutes at 37°C. Ke eping the
            plate away  from drafts and other  temperature  fluctuations  in
            the dark.
            5.  Add 50µl of Stop Solution to each well. If color change does
            not appear uniform, gently  tap  the plate  to ensure  thorough
            mixing.
            6.  Determine the optical density of each well within 10 minutes,
            using a microplate reader set to 450 nm.
            CALCULATION OF RESULTS
            Using  the  professional  soft  "Curve  Exert  1.3"  to  make  a  standard  curve  is
            recommended, which can be downloaded from our web.
            Average  the duplicate  readings  for each standard, control, and 
              10
            sample and subtract  the average zero standard optical density.
            Create  a  standard  curve  by  reducing  the  data  using  computer
            software capable of generating a  four parameter  logistic  (4-PL)
            curve-fit. As an alternative, construct a standard curve by plotting
            the mean  absorbance  for  each  standard  on  the  y-axis  against
            the concentration on the x-axis and draw a best fit curve through
            the points on  the graph. The data may be  linearized by plotting
            the log of the IL-6 concentrations versus the log of the O.D. and
            the best  fit  line can be determined by  regression analysis. This
            procedure will  produce  an  adequate  but  less  precise  fit  of  the
            data. If samples have been diluted, the concentration read from
            the standard curve must be multiplied by the dilution factor.
            LIMITATIONS OF THE PROCEDURE
              The kit should not be used beyond the expiration date on the
            kit label.
              Do not mix or substitute reagents with those from other lots or
            sources.
              If samples generate values higher than the highest standard,
            dilute the samples with the appropriate Diluent and repeat the
            assay. 
              11
              Any  variation  in  operator,  pipetting  technique,  washing
            technique,  incubation  time  or  temperature,  and  kit  age  can
            cause variation in binding.
              This  assay  is  designed  to  eliminate  interference  by  soluble
            receptors,  binding  proteins,  and  other  factors  present  in
            biological samples. Until all  factors have been  tested  in  the
            Quantikine  Immunoassay,  the  possibility  of  interference
            cannot be excluded.
            TECHNICAL HINTS
              Centrifuge vials before opening to collect contents.
              When mixing or reconstituting protein solutions, always avoid
            foaming.
              To  avoid  cross-contamination,  change  pipette  tips  between
            additions of each standard  level, between sample additions,
            and between reagent additions. Also, use separate reservoirs
            for each reagent.
              When using an automated plate washer, adding a 30 second
            soak  period  following  the  addition  of  wash  buffer,  and/or
            rotating  the  plate  180  degrees  between  wash  steps  may
            improve assay precision. 
              12
              To ensure accurate results, proper adhesion of plate sealers
            during incubation steps is necessary.
              Substrate Solution should remain colorless or light blue until
            added  to  the plate. Keep Substrate Solution protected  from
            light. Substrate Solution should change from colorless or light
            blue to gradations of blue.
              Stop Solution should be added to the plate in the same order
            as  the Substrate Solution. The color developed  in  the wells
            will turn from blue to yellow upon addition of the Stop Solution.
            Wells  that are green  in color  indicate  that  the Stop Solution
            has not mixed thoroughly with the Substrate Solution. 
             
             

            慧嘉生物您實驗身邊的好伙伴
            為客戶提供“zui高品質(zhì)的產(chǎn)品”和“zui的服務”
            AssayBiotech  CUSABIO   Immunoway  Santa   Abcam   Cst   jackson   Pierce  Sigma  Amresco  Qiagen  Cayman  abnova  millipore  invitrogen  merk  ebioscience prospec
             LifeSpan  BD 歡迎廣大客戶咨詢,另有大量宣傳海報和小禮品贈送。
            www.biohj.com  
            :382603320   1284882975

            :     

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =

            請輸驗證碼

            收藏該商鋪

            X
            該信息已收藏!
            標簽:
            保存成功

            (空格分隔,最多3個,單個標簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復您~
            撥打電話
            在線留言