            CSB-E06782p 豬白介素1β (IL-1β)ELISA Kit說明書

            時間:2013/4/23閱讀:404
            分享:

            Porcine Interleukin1β(IL-1β)
            ELISA Kit
             
             
             
            Catalog No. CSB-E06782p
            (96T)
             
             
             
             
             
             
             
            ?  This immunoassay kit allows for the in vitro quantitative determination of porcine
            IL-1β concentrations in serum, plasma.
            ?  Expiration date    six months from the date of manufacture
            ?  FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
             
              1
            PRINCIPLE OF THE ASSAY
            The microtiter plate provided in this kit has been pre-coated with
            an antibody specific to IL-1β. Standards or samples are then
            added to the appropriate microtiter plate wells with a Horseradish
            Peroxidase (HRP)-conjugated monoclonal antibody preparation
            specific for IL-1β and incubated. Then substrate solution A and B
            are added to each well. Only those wells that contain IL-1β,
            HRP-conjugated antibody will exhibit a change in color. The
            enzyme-substrate reaction is terminated by the addition of a
            sulphuric acid solution and the color change is measured
            spectrophotometrically at a wavelength of 450 nm ± 2 nm. The
            concentration of IL-1β  in the samples is then determined by
            comparing the O.D. of the samples to the standard curve.
            DETECTION RANGE
            The standard curve concentrations used for the ELISA’s were
            250pg/ml, 125pg/ml, 62.5pg/ml, 31.2pg/ml, 12.5pg/ml,
            6.25pg/ml.
            SPECIFICITY
            This assay recognizes recombinant and natural porcine IL-1β.
            No significant cross-reactivity or interference was observed.
              2
            SENSITIVITY
            The minimum detectable dose of porcine IL-1β is typically less
            than 3.125 pg/ml. The sensitivity of this assay, or Lower Limit of
            Detection (LLD) was defined as the lowest concentration that
            could be differentiated from zero.
            MATERIALS PROVIDED
            Reagent    Quantity
            Assay plate  1
            Standard(S1-S6)  6
            HRP-conjugate  1 x 6 ml
            Wash Buffer      
            1 x 15 ml
            (20×concentrate)
            Substrate A  1 x 6 ml
            Substrate B  1 x 6 ml
            Stop Solution      1x 6 ml
            Standard  S1  S2  S3  S4  S5  S6
            Concentration
            (pg/ml)
            6.25  12.5  31.2  62.5  125  250
            STORAGE
            1. Unopened test kits should be stored at 2-8?C upon receipt
            and the microtiter plate should be kept in a sealed bag. The
            test kit may be used throughout the expiration date of the kit,
            provided it is stored as prescribed above. Refer to the
            package label for the expiration date.
              3
            2. Opened test plate should be stored at 2-8?C in the aluminum
            foil bag with desiccants to minimize exposure to damp air. The
            kits will remain stable until the expiring date shown, provided it
            is stored as prescribed above.  
            3. A microtiter plate reader with a bandwidth of 10 nm or less
            and an optical density range of 0-3 OD or greater at 450nm
            wavelength is acceptable for use in absorbance
            measurement.
            REAGENT PREPARATION
            1. Bring all reagents and plate to room temperature  for at least
            30 minutes before use. Unused wells need store at 2-8°C and
            avoid sunlight.
            2. Wash Buffer   If crystals have formed in the concentrate,
            warm to room temperature and mix gently until the crystals
            have compley dissolved. Dilute 15 ml of Wash Buffer
            Concentrate into deionized or distilled water to prepare 300 ml
            of Wash Buffer.
            OTHER SUPPLIES REQUIRED
            ?  Microplate reader capable of measuring absorbance at 450
            nm, with the correction wavelength set at 540 nm or 570 nm.
            ?  Pipettes and pipette tips.
              4
            ?  Deionized or distilled water.
            ?  Squirt bottle, manifold dispenser, or automated microplate
            washer.
            ?  An incubator which can provide stable incubation conditions
            up to 37°C±0.5°C.
            SAMPLE COLLECTION AND STORAGE
            ?  Serum  Use a serum separator tube (SST) and allow
            samples to clot for 30 minutes before centrifugation for 15
            minutes at 1000 g. Remove serum and assay immediay or
            aliquot and store samples at  -20°C. Centrifuge the sample
            again after thawing before  the assay. Avoid repeated
            freeze-thaw cycles.
            ?  Plasma   Collect plasma using citrate, EDTA, or heparin as
            an anticoagulant. Centrifuge for 15 minutes at 1000 g within
            30 minutes of collection. Assay immediay or aliquot and
            store samples at -20°C. Centrifuge the sample again after
            thawing before the assay. Avoid repeated freeze-thaw cycles.
            Note: Grossly hemolyzed samples are not suitable for use in this assay.
            ASSAY PROCEDURE
            Bring all reagents and samples to room temperature before use. It is
            recommended that all samples, standards, and controls be assayed in duplicate.
            All the reagents should be added directly to the  liquid level in the well. The
            pipette should avoid contacting the inner wall of the well.
              5
            1.  Set a Blank well without any solution. Add 100μl of Standard
            or Sample per well. Standard need test in duplicate.  
            2. Add 50μl of HRP-conjugate to each well (not to Blank well).
            Mix well and then incubate for 2 hours at 37°C.  
            3.  Complete remove the liquid. Then fill each well with Wash
            Buffer (about 200μl), stay for 10 seconds and Spinning.
            Repeat the process for a total  of three washes. Complete
            removal of liquid at each step is essential to good
            performance. After the last wash, remove any remaining
            Wash Buffer by aspirating or decanting. Invert the plate and
            blot it against clean paper towels.
            4. Add 50μl of Substrate A and 50μl of Substrate B to each
            well, mix well. Incubate for 15 minutes at 37°C. Keeping the
            plate away from drafts and other temperature fluctuations in
            the dark.
            5. Add 50μl of Stop Solution to each well. If color change does
            not appear uniform, gently tap the plate to ensure thorough
            mixing.
            6.  Determine the optical density of each well within 10 minutes,
            using a microplate reader set to 450 nm.
            CALCULATION OF RESULTS
            Using the professional soft "Curve Exert  1.3" to make a standard curve is
            recommended, which can be downloaded from our web.
              6
            Average the duplicate readings for each standard, control, and
            sample and subtract the average zero standard optical density.
            Create a standard curve by reducing the data using computer
            software capable of generating a four parameter logistic (4-PL)
            curve-fit. As an alternative, construct a standard curve by plotting
            the mean absorbance for each standard on the y-axis against
            the concentration on the x-axis and draw a best fit curve through
            the points on the graph. The data may be linearized by plotting
            the log of the IL-1β concentrations versus the log of the O.D. and
            the best fit line can be determined by regression analysis. This
            procedure will produce an adequate but less precise fit of the
            data. If samples have been diluted, the concentration read from
            the standard curve must be multiplied by the dilution factor.
            LIMITATIONS OF THE PROCEDURE
            ?  The kit should not be used beyond the expiration date on the
            kit label.
            ?  Do not mix or substitute reagents with those from other lots or
            sources.
            ?  If samples generate values higher than the highest standard,
            dilute the samples with the appropriate Diluent and repeat the
            assay.
              7
            ? Any variation in operator, pipetting technique, washing
            technique, incubation time or  temperature, and kit age can
            cause variation in binding.
            ?  This assay is designed to eliminate interference by soluble
            receptors, binding proteins,  and other factors present in
            biological samples. Until all factors have been tested in the
            Immunoassay, the possibility of interference cannot be
            excluded.
            TECHNICAL HINTS
            ?  Centrifuge vials before opening to collect contents.
            ?  When mixing or reconstituting protein solutions, always avoid
            foaming.
            ?  To avoid cross-contamination, change pipette  tips between
            additions of each standard level, between sample additions,
            and between reagent additions. Also, use separate reservoirs
            for each reagent.
            ?  When using an automated plate washer, adding a 30 second
            soak period following the addition of wash buffer, and/or
            rotating the plate 180 degrees between wash steps may
            improve assay precision.
            ?  To ensure accurate results, proper adhesion of plate sealers
            during incubation steps is necessary.
              8
              9
            ?  Substrate Solution should remain colorless or light blue until
            added to the plate. Keep Substrate Solution protected from
            light. Substrate Solution should change from colorless or light
            blue to gradations of blue.
            ?  Stop Solution should be added to the plate in the same order
            as the Substrate Solution. The color developed in the wells
            will turn from blue to yellow upon addition of the Stop Solution.
            Wells that are green in color indicate that the Stop Solution
            has not mixed thoroughly with the Substrate Solution. 
             
             
             

            慧嘉生物您實驗身邊的好伙伴
            為客戶提供“zui高品質(zhì)的產(chǎn)品”和“zui的服務(wù)”
            AssayBiotech  CUSABIO   Immunoway  Santa   Abcam   Cst   jackson   Pierce  Sigma  Amresco  Qiagen  Cayman  abnova  millipore  invitrogen  merk  ebioscience prospec
             LifeSpan  BD 歡迎廣大客戶咨詢,另有大量宣傳海報和小禮品贈送。
            www.biohj.com  
            :382603320   1284882975

            :     

            會員登錄

            ×

            請輸入賬號

            請輸入密碼

            =

            請輸驗證碼

            收藏該商鋪

            X
            該信息已收藏!
            標簽:
            保存成功

            (空格分隔,最多3個,單個標簽最多10個字符)

            常用:

            提示

            X
            您的留言已提交成功!我們將在第一時間回復(fù)您~
            撥打電話
            在線留言