狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            | 注冊| 產(chǎn)品展廳| 收藏該商鋪

            行業(yè)產(chǎn)品

            當(dāng)前位置:
            成都光馳科技有限公司>>激光分析測試>>光束分析儀>> M2SET-BP209光束分析儀

            光束分析儀

            返回列表頁
            • 光束分析儀
            收藏
            舉報
            參考價 面議
            具體成交價以合同協(xié)議為準(zhǔn)
            • 型號 M2SET-BP209
            • 品牌 Thorlabs
            • 廠商性質(zhì) 代理商
            • 所在地 成都市
            在線詢價 收藏產(chǎn)品

            更新時間:2020-08-07 15:17:17瀏覽次數(shù):4207

            聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!

            同類優(yōu)質(zhì)產(chǎn)品

            更多產(chǎn)品

            產(chǎn)品簡介

            光束分析儀特點:
            可以測量發(fā)散度、光腰直徑、瑞利范圍和像散
            可以兼容連續(xù)波激光光源和重復(fù)率 ≥ 300 kHz的準(zhǔn)連續(xù)波脈沖激光光源
            光束質(zhì)量測量符合ISO11146認(rèn)證
            可直接使用的完整系統(tǒng),具有緊湊和靈活的設(shè)計
            經(jīng)TCP/IP將實時數(shù)據(jù)傳輸?shù)?DataSocket 服務(wù)器,易于讓其它程序?qū)ζ溥M行處理

            詳細介紹

            THORLABS  M2SET-BP209 光束分析儀技術(shù)參數(shù)

            完整的預(yù)先裝配和預(yù)先對準(zhǔn)系統(tǒng) 
            光束質(zhì)量測量精度為典型的5% 
            可以測量發(fā)散度、光腰直徑、瑞利范圍和像散 
            可以兼容連續(xù)波激光光源和重復(fù)率 ≥ 300 kHz的準(zhǔn)連續(xù)波脈沖激光光源 
            光束質(zhì)量測量符合ISO11146認(rèn)證 
            可直接使用的完整系統(tǒng),具有緊湊和靈活的設(shè)計 
            經(jīng)TCP/IP將實時數(shù)據(jù)傳輸?shù)?DataSocket 服務(wù)器,易于讓其它程序?qū)ζ溥M行處理。
            Item # M2SET-BP209VIS M2SET-BP209VIS/M M2SET-BP209IR M2SET-BP209IR/M
            Component Type Imperial Metric Imperial Metric
            Breadboard Footprint 24" x 6" 600 mm x 150 mm 24" x 6" 600 mm x 150 mm
            Beam Profiler BP209-VIS BP209-VIS/M BP209-IR BP209-IR/M
            Wavelength Range 400 nm to 1100 nm 900 nm to 1700 nm
            M² Measurement Range ≥ 1.0
            Typical M² and K Accuracy ±5 %, Depending on Optics and Alignment
            Beam Diameter Range at Beam Profiler Input Aperture 20 µm to 9 mm
            Accepted Beam Diameter at Beam Profiler Input Aperture for 5% Accuracy in M² Measurement 20 µm to 4.5 mm
            Maximum Input Beam Diameter at the Lensa 14 mm, Depending on Wavelength
            (See Diagram Below)
            20 mm, Depending on Wavelength
            (See Diagram Below)
            Minimum Detectable Divergence Angle  less than 0.1 mrad
            Applicable Light Sources CW and Pulsed Sources ≥ 300 kHz
            Power Range 10 nW to 10 W, Depending on Beam Diameter
            Translation Range 150 mm
            -100 mm to +50 mm from Focal Point
            Lens Focal Length 200 mm
            Optical Axis Height 50 mm to 120 mmb
            Typical Measurement Time 20 s to 40 s, Depending on Beam Shape and Settings
            • 有關(guān)透鏡的焦距和平移臺行程如何限制M²系統(tǒng)的可測的光束直徑,請參見教程標(biāo)簽。
            • 可以用一根長支桿使用在潛望鏡組合中,延長高度。

            OPHIR M²-200s 光束分析儀

            BeamGage® Professional

            • 在少于 2 分鐘內(nèi)自動測量光束質(zhì)量
            • 微調(diào)激光器進行較佳操作
            • 符合 ISO 標(biāo)準(zhǔn)
            • 專為連續(xù)使用而開發(fā)
            • 使用 UltracalTM 獲得無以倫比的準(zhǔn)確
            • 校準(zhǔn)
            • 自動衰減調(diào)節(jié)
            • 脈沖和 CW,大多數(shù)光束直徑和功率
            • 緊湊、便攜

             

             
            Not all commercial M² measuring instruments conform to the ISO 11146 method of employing a fixed position lens and moving detector. Instead, some manufacturers use a fixed position detector and a moving lens. If the laser beam is diverging or converging within the travel range of a moving lens, the reported M² value and other results can be significantly compromised. Spiricon's M²-200s Beam Propagation Analyzer is fully ISO 11146 compliant.
            Automatic M2 - at Production Speeds
            The M²-200s optical train uses a fixed position lens and camera. The mirrors that direct the focused beam into the camera are moved to precise locations, translating the beam through both the waist region and the far field regions. All these measurements and translations, as well as incremental beam attenuation, are automatically controlled by the M²-200s software. Software improvements in the M²-200s, including more efficient algorithm execution, has decreased the measurement reporting time by 2-3 times, making it possible to report M² in under two minutes.
            Beam Propagation Analyzer: M2
            Manual M2
            Manual mode is available for beams that are too large or too small or at wavelengths outside the standard optical train.
            Beam Propagation Analyzer: M2
            Accuracy by Design
            Spiricon products are known for accuracy. Using our patented Ultracal™ calibration method and auto apeturing, to exclude noise beyond the wings of the laser beam, you are assured of the most accurate measurements in the industry.
            Designed by Our Customers
            Spiricon has redesigned the M²-200, the world's top selling beam propagation system to include customer input, increased attention to durability, and operational robustness for continuous use applications; three shifts a day, seven days a week. Novice and seasoned users will appreciate these new features along with the time-tested excellence that the Spiricon M²-200 measurement system has provided over the years.
            Main Screen Functions
            Beam Propagation Analyzer: M2

             

            Specifications for M²-200s
            General  
            Accuracy ±5% typical, ±12% waist location and Rayleigh length typical (Note: Accuracy can be degraded by a variety of situations)
            Measurement Cycle Time 2-3 minutes typical, depending on setup conditions and operating mode.
            Camera Attachment Std C-mount, 90° camera on axis rotation
            Translation System Step motor-driven lead screw
            Translation Pitch 4 mm/rev optical pitch
            Step Angle 1.8° (200 steps/rev)
            Sample Range M² - 200 s 190 - 600 mm, typical
            Camera Specifications (for GRAS20 camera)
            Imager 1/1.8" CCD, 1600 x 1200 pixels
            Dynamic Range 12 bit A to D
            Frame Rates 7.5 FPS (at full resolution)
            Pixel size 4.4um x 4.4um
            Gain 0 to 25dB
            Shutter Control Programmable from 110us to 70ms
            S/N Ratio 59dB at min gain
            Trigger Input Edge sensitive 3.3 / 5Vdc LVTTL / TTL (positive or negative, user programmable)
              Minimum pulse width 10us
            Trigger Out External Trigger cable provided.
            Voltage Requirement 3.3Vdc LVTTL, Programmable
            Power Consumption Powered over Firewire Cable
              <3.5watts
            Dimensions 44mm (1.74") wide, 29mm (1.14") tall and 66mm(2.6") deep
            Mass 104g (3.7oz)
            Environmental
            Storage Temperature -30°C to 65°C
            Storage Humidity 95% maximum (non-condensing)
            Operating Temperature 10°C to 40°C
            Operating Humidity 95% maximum (non-condensing)
            Power Requirements*
            Line Voltage 95V AC to 250V AC
            Line Frequency 47Hz to 63Hz
            Maximum Power 4.5 Watts
            * For the Optical Train only. The PC computer supplies the power for the system components, such as the CCD camera. An external power supply is provided for Laptop computer use.
            Physical
            Weight M²-200… 5.9 Kg (without camera)
            Measurements M²x, M²y, Kx, Ky, BPPx, BPPy
            (Statistical results Width at waist , Wy
            are available on Divergence angle qx, qy
            all measurements) Waist location Zx, Zy
              Rayleigh X, Y
              Astigmatism
              Asymmetry ratio
            Wavelength Range  
            Different lenses are needed for different wavelength regions.
            The M²-200s model include 3 standard lenses with nominal 300mm focal lengths. See below.
            M²-200s-FW 266 - 587nm (included)
              400 - 750nm (included)
              650 - 1125nm (included)
              1000 - 1300nm (optional)
            Attenuation Range Nominally from ND 0 to ND 4.8. Actual values vary with wavelength.
            Beam Size 0.5mm - 10mmM   ²-200s
              varies with wavelength, waist size and location, and M²
            Damage Limits¹  
            Camera 0.15 uW/cm² CW mode for a 10 mm input beam diameter
              1.0 uJ/cm² pulse mode for a 10 mm input beam diameter
              Both of the above for an M² =1 @ 1064nm
            ¹ CCD cameras can be damaged by power in excess of 100 mW/cm² or energy in excess of 100 mJ/cm². The M²-200s employs a focusing optic. While it may be that the laser input power or energy measures well below this damage threshold, it can easily exceed these levels when focused onto the camera sensor. Use caution and error on the side of safety. CCD cameras can be costly to repair or replace.

            收藏該商鋪

            登錄 后再收藏

            提示

            您的留言已提交成功!我們將在第一時間回復(fù)您~
            二維碼 意見反饋
            在線留言