狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            | 注冊| 產(chǎn)品展廳| 收藏該商鋪

            行業(yè)產(chǎn)品

            當(dāng)前位置:
            杭州譜鐳光電技術(shù)有限公司>>光譜儀附件>>光纖和探頭>> RIP拉曼探頭

            拉曼探頭

            返回列表頁
            • 拉曼探頭
            收藏
            舉報
            參考價 面議
            具體成交價以合同協(xié)議為準(zhǔn)
            • 型號 RIP
            • 品牌
            • 廠商性質(zhì) 代理商
            • 所在地 杭州市
            在線詢價 收藏產(chǎn)品

            更新時間:2017-06-21 14:00:38瀏覽次數(shù):1194

            聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!

            同類優(yōu)質(zhì)產(chǎn)品

            更多產(chǎn)品

            產(chǎn)品簡介

            We offer several fiber optic probes for Raman spectroscopy.

            詳細(xì)介紹

            Probes for Raman Spectroscopy

            Raman Probe

             

             

            We offer several fiber optic probes for Raman spectroscopy. The RIP-series probes described here are from our partner InPhotonics, and provide optical filtering of the Rayleigh line and high signal collection in a compact, rugged design. Several probe models are available for laboratory, industrial and environmental applications and are available for several excitation wavelengths.

            These probes are compatible with Ocean Optics systems configured for Raman spectroscopy.

             

            ItemDescriptionProbe Size (mm)Price
            RIP-RPB-532RIP-PRB* laboratory probe for use with lasers up to 3 nm from specified operating wavelength; comes with 7.5-mm focal length; use this item for 532 nm excitation wavelength set-ups114 x 38 x 12.7;
            1.5-meter fiber
            $2750
            RIP-RPB-785RIP-PRB* laboratory probe for use with lasers up to 3 nm from specified operating wavelength; comes with 7.5-mm focal length; use this item for 785 nm excitation wavelength set-ups114 x 38 x 12.7;
            1.5-meter fiber
            Call for Price
            RIP-RPS-532-IPStainless-steel focused probe for lab and field use; comes with 5-mm focal length (7.5 mm or 10 mm available) for 532 nm excitation wavelength set-ups12.7 OD x 101 length;
            5-meter fiber
            $4950
            RIP-RPS-785Stainless-steel focused probe for lab and field use; comes with 5-mm focal length (7.5 mm or 10 mm available) for 785 nm excitation wavelength set-ups12.7 OD x 101 length;
            5-meter fiber
            $4950
            RIP-RP2-532Stainless-steel immersion probe is immersible up to 200 °C and has adjustable working distance for 532 nm excitation wavelength set-ups15.87 OD x 203 length;
            5-meter fiber
            $6745
            RIP-RP2-785Stainless-steel immersion probe is immersible up to 200 °C and has adjustable working distance for 785 nm excitation wavelength set-ups15.87 OD x 203 length;
            5-meter fiber
            $6745
            RIP-RPR-H-532Hasloy C immersion probe for use in process control applications up to 200 °C and 1500 psi; comes with sapphire window and has adjustable working distance for 532 nm excitation wavelength set-ups15.87 OD x 330 length;
            5-meter fiber
            $9200
            RIP-RPR-H-785Hasloy C immersion probe for use in process control applications up to 200 °C and 1500 psi; comes with sapphire window and has adjustable working distance for 785 nm excitation wavelength set-ups15.87 OD x 330 length;
            5-meter fiber
            $9200
            RIP-RPP-532Stainless-steel probe with external optics for process control applications up to 500 °C and 3000 psi; comes with sapphire lens and has short working distance for 532 nm excitation wavelength set-ups9.52 OD x 300 length;
            5-meter fiber
            $10200
            RIP-RPP-785Stainless-steel probe with external optics for process control applications up to 500 °C and 3000 psi; comes with sapphire lens and has short working distance for 785 nm excitation wavelength set-ups9.52 OD x 300 length;
            5-meter fiber
            $10200
            RIP-PA-SHSample holder with inserts for round vials, square cuvettes, and solid sample cupsNot applicable$850
            RIP-RPR-SS-532Stainless-steel immersion probe for use in process control applications up to 200 °C and 1500 psi; sapphire window with adjustable working distance for 532 nm excitation wavelength set-ups15.87 OD x 330 length;
            5-meter fiber
            $8200
            RIP-RPR-SS-785Stainless-steel immersion probe for use in process control applications up to 200 °C and 1500 psi; sapphire window with adjustable working distance for 785 nm excitation wavelength set-ups15.87 OD x 330 length;
            5-meter fiber
            $8200
            ItemDescriptionProbe Size (mm)Price
            RIP-RPB-532RIP-PRB* laboratory probe for use with lasers up to 3 nm from specified operating wavelength; comes with 7.5-mm focal length; use this item for 532 nm excitation wavelength set-ups114 x 38 x 12.7;
            1.5-meter fiber
            $2750
            RIP-RPB-785RIP-PRB* laboratory probe for use with lasers up to 3 nm from specified operating wavelength; comes with 7.5-mm focal length; use this item for 785 nm excitation wavelength set-ups114 x 38 x 12.7;
            1.5-meter fiber
            Call for Price
            RIP-RPS-532-IPStainless-steel focused probe for lab and field use; comes with 5-mm focal length (7.5 mm or 10 mm available) for 532 nm excitation wavelength set-ups12.7 OD x 101 length;
            5-meter fiber
            $4950
            RIP-RPS-785Stainless-steel focused probe for lab and field use; comes with 5-mm focal length (7.5 mm or 10 mm available) for 785 nm excitation wavelength set-ups12.7 OD x 101 length;
            5-meter fiber
            $4950
            RIP-RP2-532Stainless-steel immersion probe is immersible up to 200 °C and has adjustable working distance for 532 nm excitation wavelength set-ups15.87 OD x 203 length;
            5-meter fiber
            $6745
            RIP-RP2-785Stainless-steel immersion probe is immersible up to 200 °C and has adjustable working distance for 785 nm excitation wavelength set-ups15.87 OD x 203 length;
            5-meter fiber
            $6745
            RIP-RPR-H-532Hasloy C immersion probe for use in process control applications up to 200 °C and 1500 psi; comes with sapphire window and has adjustable working distance for 532 nm excitation wavelength set-ups15.87 OD x 330 length;
            5-meter fiber
            $9200
            RIP-RPR-H-785Hasloy C immersion probe for use in process control applications up to 200 °C and 1500 psi; comes with sapphire window and has adjustable working distance for 785 nm excitation wavelength set-ups15.87 OD x 330 length;
            5-meter fiber
            $9200
            RIP-RPP-532Stainless-steel probe with external optics for process control applications up to 500 °C and 3000 psi; comes with sapphire lens and has short working distance for 532 nm excitation wavelength set-ups9.52 OD x 300 length;
            5-meter fiber
            $10200
            RIP-RPP-785Stainless-steel probe with external optics for process control applications up to 500 °C and 3000 psi; comes with sapphire lens and has short working distance for 785 nm excitation wavelength set-ups9.52 OD x 300 length;
            5-meter fiber
            $10200
            RIP-PA-SHSample holder with inserts for round vials, square cuvettes, and solid sample cupsNot applicable$850
            RIP-RPR-SS-532Stainless-steel immersion probe for use in process control applications up to 200 °C and 1500 psi; sapphire window with adjustable working distance for 532 nm excitation wavelength set-ups15.87 OD x 330 length;
            5-meter fiber
            $8200
            RIP-RPR-SS-785Stainless-steel immersion probe for use in process control applications up to 200 °C and 1500 psi; sapphire window with adjustable working distance for 785 nm excitation wavelength set-ups15.87 OD x 330 length;
            5-meter fiber
            $8200

            * RIP-RPB is available for 532 nm, 633 nm and 785 nm excitation wavelengths; additional excitation wavelength options are available on request. RIP-RPB Probes have laser filtering of 106. All other probes are available for 514 nm, 532 nm, 670 nm, 785 nm and 830 nm excitation wavelengths, with laser filtering of 108.

            其他推薦產(chǎn)品