狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            產(chǎn)品展廳收藏該商鋪

            您好 登錄 注冊

            當前位置:
            美國布魯克海文儀器公司>資料下載>NanoBrook產(chǎn)品應用-13-ZetaPALS

            資料下載

            NanoBrook產(chǎn)品應用-13-ZetaPALS

            閱讀:299          發(fā)布時間:2015-4-10
            提 供 商 美國布魯克海文儀器公司 資料大小 0K
            資料圖片 下載次數(shù) 0次
            資料類型 瀏覽次數(shù) 299次
            免費下載    
             文獻名: Highly Sensitive Immunoassay for the Diagnosis of Acute Myocardial Infarction Using Silica Spheres Encapsulating a Quantum Dot Layer
             
            作者: Hyojeong Han †, Jae-Chul Pyun ‡, Hyein Yoo †, Hong Seog Seo §, Byung Hwa Jung †, Young Sook Yoo †, Kyoungja Woo *†, and Min-Jung Kang *†
            † Molecular Recognition Research Center, Korea Institute of Science and Technology (KIST), Seoul 136-791, Republic of Korea
            ‡ Department of Materials Science and Engineering, Yonsei University, Seoul 120-749, Republic of Korea
            § Cardiovascular Center, Korea University Guro Hospital, Korea University College of Medicine, Seoul 152-703, Republic of Korea
             
            摘要:Commercial ELISA kits for substance P (SubP), which are helpful for the clinical diagnosis of acute myocardial infarction, are limited in efficacy because of low sensitivity. A highly sensitive immunoassay was developed using silica spheres encapsulating a quantum dot-layer (SQS) and labeling antibodies, on a Parylene A-modified plate. The high sensitivity was possible by taking advantage of the enhanced photoluminescence of the SQS and dense immobilization of SubP on a Parylene A-modified plate. Glutaraldehyde was used for cross-linking of SQS to the anti-SubP antibody and SubP to the Parylene A coating. The SQS-linked immunosorbent assay (SQSLISA) was optimized and validated. The dynamic range for the assay was 1–10000 pg/mL with a linear correlation factor of 0.9992 when the competitive SQSLISA was employed. The intra- and interday accuracies were 93–100% and 87–122%, respectively. The reproducibility was lower than 11%. The developed method was applied to clinical samples collected from healthy controls (n = 30) and acute myocardial infarction (n = 16) and it displayed a high correlation with the commercial ELISA kit, with a limit of detection that was 30-fold lower. Clinical sample analysis confirmed that SubP is a promising diagnostic marker for acute myocardial infarction. The SQSLISA is expected to be a practical and useful assay tool.

            收藏該商鋪

            登錄 后再收藏

            提示

            您的留言已提交成功!我們將在第一時間回復您~

            對比框

            產(chǎn)品對比 產(chǎn)品對比 聯(lián)系電話 二維碼 意見反饋 在線交流

            掃一掃訪問手機商鋪
            010-62081908
            在線留言