狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            產(chǎn)品展廳收藏該商鋪

            您好 登錄 注冊

            當(dāng)前位置:
            美國布魯克海文儀器公司>資料下載>測量應(yīng)用案例-20210206

            資料下載

            測量應(yīng)用案例-20210206

            閱讀:104          發(fā)布時間:2021-2-23
            提 供 商 美國布魯克海文儀器公司 資料大小 1.2MB
            資料圖片 下載次數(shù) 21次
            資料類型 PDF 文件 瀏覽次數(shù) 104次
            免費下載 點擊下載    
             文獻(xiàn)名: Electrospinning fabrication of covalent organic framework composite nanofibers for pipette tip solid phase extraction of tetracycline antibiotics in grass carp and duck

             

            作者: Ronglin Wanga; Canru Lia; Qianlian Lia; Sunxian Zhangb; Feng lva; Zhiming Yana

            aCollge of Food Science, Fujian Agriculture and Forestry University, 350002, Fuzhou, Fujian, China

            bFujian Inspection and Research Institute for Product Quality, 350001, Fuzhou, Fujian, China

             

            摘要:In the current study, a novel covalent organic frameworks COF-SCU1 incorporated electrospun nanofibers (PAN@COF-SCU1 nanofibers) was fabricated via a facile electrospinning method and utilized as adsorbent in pipette tip solid-phase extraction (PT-SPE) of tetracycline antibiotics (TCs) from foods. The prepared PAN@COF-SCU1 nanofibers possessed both of the unique characteristics of electrospun nanofibers and COFS-CU1, and thus improving the adsorption capacity of the electrospun nanofibers and preventing the problems of leakage and high pressure caused by directly using the nanosize COFs as adsorbent in PT-SPE. The experiments affected the adsorption and desorption efficiencies, such as the loading ratios of COFS-CU1 in nanofibers, the amount of nanofibers, the matrix pH and desorption solvent, were studied in detail. Eventually, a new pipette tip solid-phase extraction-high performance liquid chromatography (PT-SPE/HPLC) method was proposed for the analysis of three TCs from food. Satisfied linearity for TCs was obtained in the range of 470 ng mL1. The limits of detection and quantification were ranged from 0.6 to 3 ng mL1 and from 2 to 10 ng mL1, respectively. The interday and intraday precisions (RSD) were all lower than 9%. The proposed PT-SPE/HPLC method was used to determine TCs residues in grass carp and duck samples for the first time. The results could not only explore the availability of PT-SPE in the extraction of TCs in food samples, but also broadened the potential applications of COFs in sample preparation.

            收藏該商鋪

            登錄 后再收藏

            提示

            您的留言已提交成功!我們將在第一時間回復(fù)您~

            對比框

            產(chǎn)品對比 產(chǎn)品對比 聯(lián)系電話 二維碼 在線交流

            掃一掃訪問手機商鋪
            010-62081908
            在線留言