大鼠血管緊張素Ⅱ(ANG-Ⅱ)ELISA試劑盒
廈門慧嘉生物經(jīng)營ELISA試劑盒及抗體、細(xì)胞因子、生化試劑、耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價(jià)格實(shí)惠,服務(wù)周到,質(zhì)量有保證。: : http://www.biohj.com/download.aspx(說明書下載) 該說明書是PDF格式轉(zhuǎn)化的,固排版有所變化, 歡迎或或索取原版說明書
----------------------- Page 1-----------------------
Rat angiotension ⅡⅡ(ANG- ⅡⅡ)
ⅡⅡ ⅡⅡ
ELISA Kit
Catalog No. CSB-E04494r
(96 T)
This immunoassay kit allows for the in vitro quantitative determination of Rat
ANG-II concentrations in serum, plasma and other biological fluids.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
1
INTRODUCTION Angiotensin is an oligopeptide hormone that circulates in the blood and which causes vasoconstriction, increased blood pressure, and release of aldosterone from the adrenal cortex. It is also a powerful dipsogen as a result of its actions on the brain. It is derived from the precursor molecule angiotensinogen, a serum globulin produced in the liver. It plays an important role in the renin-angiotensin system, an endocrine system that helps regulate long-term blood pressure and blood volume in the body. The system can be activated when there is a loss of blood volume or a fall in blood pressure. Angiotensin I is converted to angiotensin II by angiotensin-converting enzyme (ACE), which is found mainly in lung capillaries. Angiotensin II (ANG II) plays an important role in vascular disease, and angiotensin-converting enzyme inhibitors or Ang II type 1 receptor antagonists can lower blood pressure and reverse vascular remodeling in patients with hypertension or in spontaneously hypertensive rats. Ang II exerts some of its effects on the vasculature by stimulating expression of growth factors including basic fibroblast growth factor, plaet-derived growth factor, TGF , IGF-I and the IGF-I receptor (IGF-IR). PRINCIPLE OF THE ASSAY The microtiter plate provided in this kit has been pre-coated with an antibody specific to ANG-II. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody 2 preparation specific for ANG-II and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain ANG-II, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of ANG-II in the samples is then determined by comparing the O.D. of the samples to the standard curve. DETECTION RANGE 0.45 pg/ml-30 pg/ml. The standard curve concentrations used for the ELISA’s were 30 pg/ml,15 pg/ml,7.5 pg/ml,3.75 pg/ml,1.8 pg/ml,0.9 pg/ml,0.45 pg/ml. SPECIFICITY This assay recognizes recombinant and natural Rat ANG-II. No significant cross-reactivity or interference was observed. SENSITIVITY The minimum detectable dose of Rat ANG-II is typically less than 0.1 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. 3 MATERIALS PROVIDED Reagent Quantity Assay plate 1 Standard 2 Sample Diluent 1 x 20 ml Biotin-antibody Diluent 1 x 10 ml HRP-avidin Diluent 1 x 10 ml Biotin-antibody 1 x 120μl HRP-avidin 1 x 120μl 1 x 20 ml Wash Buffer (25×concentrate) TMB Substrate 1 x 10 ml Stop Solution 1 x 10 ml STORAGE 1. Unopened test kits should be stored at 2-8°C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date. 2. Opened test plate should be stored at 2-8°C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above. 3. A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement. 4 REAGENT PREPARATION Bring all reagents to room temperature before use. 1. Wash Buffer If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have compley dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer. 2. Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 30 pg/ml. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (30 pg/ml). The Sample Diluent serves as the zero standard (0 pg/ml). Prepare fresh for each assay. Use within 4 hours and discard after use. 3. Biotin-antibody Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively. 4. HRP-avidin Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively. Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material. 5 OTHER SUPPLIES REQUIRED Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm. Pipettes and pipette tips. Deionized or distilled water. Squirt bottle, manifold dispenser, or automated microplate washer. An incubator which can provide stable incubation conditions up to 37°C ±0.5°C. SAMPLE COLLECTION AND STORAGE Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum and assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles. Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles. Note: Grossly hemolyzed samples are not suitable for use in this assay. 6 ASSAY PROCEDURE Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well. 1. Add 100μl of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37°C. 2. Remove the liquid of each well, don’t wash. 3. Add 100μl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature and mix gently until solution appears uniform. 4. Aspirate each well and wash, repeating the process three times for a total of three washes. Wash: Fill each well with Wash Buffer (200μl) and let it stand for 2 minutes, then remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance. 5. Add 100μl of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C. 6. Repeat the aspiration and wash three times as step 4. 7 7. Add 90μl of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark. 8. Add 50μl of Stop Solution to each well when the first four wells containing the highest concentration of standards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing. 9. Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm. CALCULATION OF RESULTS Using the professional soft "Curve Exert 1.3" to make a standard curve is recommended, which can be downloaded from our web. Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the ANG-II concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an 8 adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor. LIMITATIONS OF THE PROCEDURE The kit should not be used beyond the expiration date on the kit label. Do not mix or substitute reagents with those from other lots or sources. It is important that the Standard Diluent selected for the standard curve be consistent with the samples being assayed. If samples generate values higher than the highest standard, dilute the samples with the appropriate Standard Diluent and repeat the assay. Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding. This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Quantikine Immunoassay, the possibility of interference cannot be excluded. TECHNICAL HINTS Centrifuge vials before opening to collect contents. When mixing or reconstituting protein solutions, always avoid foaming. 9 To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent. When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision. To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue. Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution. 10 大鼠血管緊張素大鼠血管緊張素ⅡⅡ(ANG-II)酶聯(lián)免疫分析酶聯(lián)免疫分析 大鼠血管緊張素大鼠血管緊張素ⅡⅡ 酶聯(lián)免疫分析酶聯(lián)免疫分析 試劑盒使用說明書試劑盒使用說明書 試劑盒使用說明書試劑盒使用說明書 本試劑盒僅供研究使用本試劑盒僅供研究使用 本試劑盒僅供研究使用本試劑盒僅供研究使用 產(chǎn)品編號產(chǎn)品編號::CSB-E04494r 產(chǎn)品編號產(chǎn)品編號:: 檢測范圍檢測范圍::0.45 pg/ml - 30 pg/ml 檢測范圍檢測范圍:: zui低檢測限zui低檢測限::0.1 pg/ml zui低檢測限zui低檢測限:: 特異性特異性::本試劑盒可同時(shí)檢測天然或重組的大鼠ANG-II,且與其他相關(guān)蛋 特異性特異性:: 白無交叉反應(yīng)。 有效期有效期::6 個(gè)月 有效期有效期:: 預(yù)期應(yīng)用預(yù)期應(yīng)用::ELISA 法定量測定大鼠血清、血漿或其它相關(guān)生物液體中 預(yù)期應(yīng)用預(yù)期應(yīng)用:: ANG-II 含量。 說明說明 說明說明 1. 試劑盒保存:未開封的試劑盒應(yīng)儲存于2-8℃;開封后的酶標(biāo)板應(yīng)與干燥 劑一起儲存于鋁箔袋中置于2-8℃保存。僅在此出儲存條件下,產(chǎn)品在有 效期內(nèi)可正常使用。 2. 濃洗滌液低溫保存會有鹽析出,稀釋時(shí)可在水浴中加溫助溶。 3. 中、英文說明書可能會有不一致之處,請以英文說明書為準(zhǔn)。 4. 剛開啟的酶聯(lián)板孔中可能會含有少許水樣物質(zhì),此為正常現(xiàn)象,不會對實(shí) 驗(yàn)結(jié)果造成任何影響。 實(shí)驗(yàn)原理實(shí)驗(yàn)原理 實(shí)驗(yàn)原理實(shí)驗(yàn)原理 用純化的抗體包被微孔板,制成固相載體,往包被抗ANG-II 抗體的微孔 中依次加入標(biāo)本或標(biāo)準(zhǔn)品、生物素化的抗ANG-II 抗體、HRP 標(biāo)記的親和素, 經(jīng)過*洗滌后用底物TMB 顯色。TMB 在過氧化物酶的催化下轉(zhuǎn)化成藍(lán)色, 并在酸的作用下轉(zhuǎn)化成zui終的黃色。顏色的深淺和樣品中的ANG-II 呈正相關(guān)。 用酶標(biāo)儀在450nm 波長下測定吸光度 (OD 值),計(jì)算樣品濃度。 11 試劑盒組成及試劑配制試劑盒組成及試劑配制 試劑盒組成及試劑配制試劑盒組成及試劑配制 1. 酶聯(lián)板酶聯(lián)板(Assay plate ): 一塊(96 孔)。 酶聯(lián)板酶聯(lián)板 2. 標(biāo)準(zhǔn)品標(biāo)準(zhǔn)品(Standard): 2 瓶(凍干品)。 標(biāo)準(zhǔn)品標(biāo)準(zhǔn)品 3. 樣品稀釋液樣品稀釋液(Sample Diluent): 1×20ml/瓶。 樣品稀釋液樣品稀釋液 4. 生物素標(biāo)記抗體稀釋液生物素標(biāo)記抗體稀釋液((Biotin-antibody Diluent):) 1×10ml/瓶。 生物素標(biāo)記抗體稀釋液生物素標(biāo)記抗體稀釋液(( )) 5. 辣根過氧化物酶標(biāo)記親和素稀釋液辣根過氧化物酶標(biāo)記親和素稀釋液((HRP-avidin Diluent)) 1×10ml/瓶。 辣根過氧化物酶標(biāo)記親和素稀釋液辣根過氧化物酶標(biāo)記親和素稀釋液(( )) 6. 生物素標(biāo)記抗體生物素標(biāo)記抗體((Biotin-antibody):) 1×120μl/瓶(1:100)。 生物素標(biāo)記抗體生物素標(biāo)記抗體(( )) 7. 辣根過氧化物酶標(biāo)記親和素辣根過氧化物酶標(biāo)記親和素((HRP-avidin):) 1×120μl/瓶(1:100)。 辣根過氧化物酶標(biāo)記親和素辣根過氧化物酶標(biāo)記親和素(( )) 8. 底物溶液底物溶液((TMB Substrate):) 1×10ml/瓶。 底物溶液底物溶液(( )) 9. 濃洗滌液濃洗滌液((Wash Buffer )) 1×20ml/瓶,使用時(shí)每瓶用蒸餾水稀釋25 倍。 濃洗滌液濃洗滌液(( )) 10. 終止液終止液((Stop Solution):) 1×10ml/瓶。 終止液終止液(( )) 需要而未提供的試劑和器材需要而未提供的試劑和器材 需要而未提供的試劑和器材需要而未提供的試劑和器材 1. 標(biāo)準(zhǔn)規(guī)格酶標(biāo)儀 2. 高速離心機(jī) 3. 電熱恒溫培養(yǎng)箱 4. 干凈的試管和Eppendof 管 5. 系列可調(diào)節(jié)移液器及吸頭,一次檢測樣品較多時(shí),用多通道移液器 6. 蒸餾水,容量瓶等 標(biāo)本的采集及保存標(biāo)本的采集及保存 標(biāo)本的采集及保存標(biāo)本的采集及保存 1. 血清:全血標(biāo)本請于室溫放置2 小時(shí)或4℃過夜后于1000g 離心20 分鐘, 取上清即可立即檢測;或進(jìn)行分裝,并將標(biāo)本放于-20℃或-80℃保存,但 應(yīng)避免反復(fù)凍融。解凍后的樣品應(yīng)再次離心,然后檢測。 2. 血漿:可用EDTA 或肝素作為抗凝劑,標(biāo)本采集后30 分鐘內(nèi)于2 - 8°C 1000 g 離心15 分鐘,取上清即可立即檢測;或進(jìn)行分裝,并將標(biāo)本放于 -20℃或-80℃保存,但應(yīng)避免反復(fù)凍融。解凍后的樣品應(yīng)再次離心,然后 檢測。 3. 細(xì)胞培養(yǎng)物上清或其它生物標(biāo)本:1000g 離心20 分鐘,取上清即可立即 檢測;或進(jìn)行分裝,并將標(biāo)本放于-20℃或-80℃保存,但應(yīng)避免反復(fù)凍融。 解凍后的樣品應(yīng)再次離心,然后檢測。 注:注:標(biāo)本溶血會影響zui后檢測結(jié)果標(biāo)本溶血會影響zui后檢測結(jié)果,因此溶血標(biāo)本不宜進(jìn)行此項(xiàng)檢測,因此溶血標(biāo)本不宜進(jìn)行此項(xiàng)檢測。。 注注::標(biāo)本溶血會影響zui后檢測結(jié)果標(biāo)本溶血會影響zui后檢測結(jié)果,,因此溶血標(biāo)本不宜進(jìn)行此項(xiàng)檢測因此溶血標(biāo)本不宜進(jìn)行此項(xiàng)檢測。。 12 標(biāo)本的稀釋原則標(biāo)本的稀釋原則:: 標(biāo)本的稀釋原則標(biāo)本的稀釋原則:: 首先通過文獻(xiàn)檢索的方式了解待測樣本的大致含量,確定適當(dāng)?shù)南♂尡稊?shù)。 只有稀釋至標(biāo)準(zhǔn)曲線的范圍內(nèi),檢測的結(jié)果才是準(zhǔn)確的。稀釋的過程中,應(yīng) 做好詳細(xì)的記錄。zui后計(jì)算濃度時(shí),稀釋了“N”倍,標(biāo)本的濃度應(yīng)再乘以“N”。 標(biāo)準(zhǔn)品的稀釋原則標(biāo)準(zhǔn)品的稀釋原則::2 瓶,使用前于6000-10000rpm 離心30 秒。每 標(biāo)準(zhǔn)品的稀釋原則標(biāo)準(zhǔn)品的稀釋原則:: 瓶臨用前以樣品稀釋液稀釋至1ml,蓋好后靜置10 分鐘以上,然后反復(fù)顛倒 /搓動以助溶解,其濃度為30 pg/ml,做系列倍比稀釋后,分別稀釋30 pg/ml, 15 pg/ml,7.5 pg/ml,3.75 pg/ml,1.8 pg/ml,0.9 pg/ml,0.45 pg/ml,樣品 稀釋液直接作為標(biāo)準(zhǔn)濃度0 pg/ml,臨用前15 分鐘內(nèi)配制,用完丟棄,下次 檢測使用新鮮配置的標(biāo)準(zhǔn)品。 如配制15 pg/ml 標(biāo)準(zhǔn)品:取0.5ml (不要少于0.5ml)30 pg/ml 的上述標(biāo)準(zhǔn) 品加入含0.5ml 樣品稀釋液的Eppendorf 管中,混勻即可,其余濃度以此類 推。 生物素標(biāo)記抗體的稀釋原則生物素標(biāo)記抗體的稀釋原則:: 生物素標(biāo)記抗體的稀釋原則生物素標(biāo)記抗體的稀釋原則:: 打開瓶蓋前請離心,收集瓶壁上的溶液。臨用前以生物素標(biāo)記抗體稀釋液稀 釋,稀釋前根據(jù)預(yù)先計(jì)算好的每次實(shí)驗(yàn)所需的總量配制 (每孔100μl),實(shí)際 配制時(shí)應(yīng)多配制0.1-0.2ml。如10μl 生物素標(biāo)記抗體加990μl 生物素標(biāo)記抗體 稀釋液的比例配制,輕輕混勻,在使用前一小時(shí)內(nèi)配制。 辣根辣根過氧化物酶標(biāo)記親和素的稀釋原則過氧化物酶標(biāo)記親和素的稀釋原則:: 辣根辣根過氧化物酶標(biāo)記親和素的稀釋原則過氧化物酶標(biāo)記親和素的稀釋原則:: 打開瓶蓋前請離心,收集瓶壁上的溶液。臨用前以辣根過氧化物酶標(biāo)記親和 素稀釋液稀釋,稀釋前根據(jù)預(yù)先計(jì)算好的每次實(shí)驗(yàn)所需的總量配制(每孔 100μl),實(shí)際配制時(shí)應(yīng)多配制0.1-0.2ml。如10μl 辣根過氧化物酶標(biāo)記親和素 加990μl 辣根過氧化物酶標(biāo)記親和素稀釋液的比例配制,輕輕混勻,在使用 前一小時(shí)內(nèi)配制。 操作步驟操作步驟 操作步驟操作步驟 實(shí)驗(yàn)開始前,請?zhí)崆芭渲煤盟性噭?,試劑或樣品稀釋時(shí),均需混勻,混勻 時(shí)盡量避免起泡。每次檢測都應(yīng)該做標(biāo)準(zhǔn)曲線。如樣品濃度過高時(shí),用樣品 稀釋液進(jìn)行稀釋,以使樣品符合試劑盒的檢測范圍。加樣時(shí),槍頭應(yīng)直接對 準(zhǔn)液面,切勿沿孔壁加樣。 13 4. 加樣:分別設(shè)空白孔、標(biāo)準(zhǔn)孔、待測樣品孔??瞻卓准訕悠废♂屢?00μl, 余孔分別加標(biāo)準(zhǔn)品或待測樣品100μl,注意不要有氣泡,加樣將樣品加于 酶標(biāo)板孔底部,盡量不觸及孔壁,輕輕晃動混勻,酶標(biāo)板加上蓋或覆膜, 37℃反應(yīng)120 分鐘。 為保證實(shí)驗(yàn)結(jié)果有效性,每次實(shí)驗(yàn)請使用新的標(biāo)準(zhǔn)品溶液。 5. 棄去液體,甩干,不用洗滌。每孔加生物素標(biāo)記抗體工作液 100μl (取1μl 生物素標(biāo)記抗體加99μl 生物素標(biāo)記抗體稀釋液的比例配制,輕輕混勻, 在使用前一小時(shí)內(nèi)配制),37℃,60 分鐘。 6. 溫育60 分鐘后,棄去孔內(nèi)液體,甩干,洗板3 次,每次浸泡1-2 分鐘, 200μl/每孔,甩干。 7. 每孔加辣根過氧化物酶標(biāo)記親和素工作液 (同生物素標(biāo)記抗體工作液) 100μl,37℃,60 分鐘。 8. 溫育60 分鐘后,棄去孔內(nèi)液體,甩干,洗板5 次,每次浸泡1-2 分鐘, 200μl/每孔,甩干。 9. 依序每孔加底物溶液90μl,37℃避光顯色 ((30 分鐘內(nèi),此時(shí)肉眼可見標(biāo) (( 準(zhǔn)品的前3-4 孔有明顯的梯度藍(lán)色,后3-4 孔顯色不明顯,即可終止)。 10. 依序每孔加終止溶液50μl,終止反應(yīng)(此時(shí)藍(lán)色立轉(zhuǎn)黃色)。終止液的加 入順序應(yīng)盡量與底物液的加入順序相同。為了保證實(shí)驗(yàn)結(jié)果的準(zhǔn)確性,底 物反應(yīng)時(shí)間到后應(yīng)盡快加入終止液。 11. 用酶聯(lián)儀在450nm 波長依序測量各孔的光密度 (OD 值)。 在加終止液 后15 分鐘以內(nèi)進(jìn)行檢測。 實(shí)驗(yàn)備注實(shí)驗(yàn)備注 實(shí)驗(yàn)備注實(shí)驗(yàn)備注 1. 用戶在初次使用試劑盒時(shí),應(yīng)將各種試劑管離心數(shù)分鐘,以便試劑集中到 管底。 2. 每次實(shí)驗(yàn)留一孔作為空白調(diào)零孔,該孔不加任何試劑,只是zui后加底物溶 液及終止液。測量時(shí)先用此孔調(diào)OD 值至零。 3. 為防止樣品蒸發(fā),試驗(yàn)時(shí)將反應(yīng)板放于鋪有濕布的密閉盒內(nèi),酶標(biāo)板加上 蓋或覆膜。 4. 未使用完的酶標(biāo)板或者試劑,請于2-8℃保存。標(biāo)準(zhǔn)品、生物素標(biāo)記抗體 工作液、辣根過氧化物酶標(biāo)記親和素工作液請依據(jù)所需的量配置使用。請 勿重復(fù)使用已稀釋過的標(biāo)準(zhǔn)品、生物素標(biāo)記抗體工作液、或辣根過氧化物 酶標(biāo)記親和素工作液。 5. 建議檢測樣品時(shí)均設(shè)雙孔測定,以保證檢測結(jié)果的準(zhǔn)確性。 14 洗板方法洗板方法 洗板方法洗板方法 手工洗板方法:吸去(不可觸及板壁)或甩掉酶標(biāo)板內(nèi)的液體;在實(shí)驗(yàn)臺上 鋪墊幾層吸水紙,酶標(biāo)板朝下用力拍幾次;將推薦的洗滌緩沖液至少0.3ml 注入孔內(nèi),浸泡1-2 分鐘。根據(jù)需要,重復(fù)此過程數(shù)次。 自動洗板:如果有自動洗板機(jī),應(yīng)在熟練使用后再用到正式實(shí)驗(yàn)過程中。 計(jì)算計(jì)算 計(jì)算計(jì)算 請從我們的下載專業(yè)軟件"Curve Exert 1.3",并根據(jù)提示制作標(biāo)準(zhǔn)曲線。 以標(biāo)準(zhǔn)物的濃度為橫坐標(biāo)(對數(shù)坐標(biāo)),OD 值為縱坐標(biāo)(普通坐標(biāo)),在半對 數(shù)坐標(biāo)紙上繪出標(biāo)準(zhǔn)曲線,根據(jù)樣品的OD 值由標(biāo)準(zhǔn)曲線查出相應(yīng)的濃度; 再乘以稀釋倍數(shù);或用標(biāo)準(zhǔn)物的濃度與OD 值計(jì)算出標(biāo)準(zhǔn)曲線的直線回歸方 程式,將樣品的OD 值代入方程式,計(jì)算出樣品濃度,再乘以稀釋倍數(shù),即 為樣品的實(shí)際濃度。 注意事項(xiàng)注意事項(xiàng) 注意事項(xiàng)注意事項(xiàng) 1. 本操作說明適用于本操作說明適用于48T 試劑盒試劑盒,, 48T 試劑盒中酶聯(lián)板試劑盒中酶聯(lián)板、標(biāo)準(zhǔn)品、標(biāo)準(zhǔn)品、生物素、生物素 本操作說明適用于本操作說明適用于 試劑盒試劑盒,, 試劑盒中酶聯(lián)板試劑盒中酶聯(lián)板、、標(biāo)準(zhǔn)品標(biāo)準(zhǔn)品、、生物素生物素 標(biāo)記抗體及辣根過氧化物酶標(biāo)記親和素減半標(biāo)記抗體及辣根過氧化物酶標(biāo)記親和素減半。。 標(biāo)記抗體及辣根過氧化物酶標(biāo)記親和素減半標(biāo)記抗體及辣根過氧化物酶標(biāo)記親和素減半。。 2. 當(dāng)混合蛋白溶液時(shí)應(yīng)盡量輕緩,避免起泡。 3. 洗滌過程非常重要,不充分的洗滌易造成假陽性。 4. 一次加樣時(shí)間控制在5 分鐘內(nèi),如標(biāo)本數(shù)量多,推薦使用排槍加樣。 5. 請每次測定的同時(shí)做標(biāo)準(zhǔn)曲線,做復(fù)孔。 6. 如標(biāo)本中待測物質(zhì)含量過高,請先稀釋后再測定,計(jì)算時(shí)請zui后乘以稀釋 倍數(shù)。 7. 在配制標(biāo)準(zhǔn)品、檢測溶液工作液時(shí),請以相應(yīng)的稀釋液配制,不能混淆。 8. 底物請避光保存。 9. 不要用其它生產(chǎn)廠家的試劑替換試劑盒中的試劑。 15 Notes 16 17 18 19 20 21
----------------------- Page 2-----------------------
----------------------- Page 3-----------------------
----------------------- Page 4-----------------------
----------------------- Page 5-----------------------
----------------------- Page 6-----------------------
----------------------- Page 7-----------------------
----------------------- Page 8-----------------------
----------------------- Page 9-----------------------
----------------------- Page 10-----------------------
----------------------- Page 11-----------------------
----------------------- Page 12-----------------------
----------------------- Page 13-----------------------
----------------------- Page 14-----------------------
----------------------- Page 15-----------------------
----------------------- Page 16-----------------------
----------------------- Page 17-----------------------
----------------------- Page 18-----------------------
----------------------- Page 19-----------------------
----------------------- Page 20-----------------------
----------------------- Page 21-----------------------
----------------------- Page 22-----------------------
請輸入賬號
請輸入密碼
請輸驗(yàn)證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),化工儀器網(wǎng)對此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。